Advertisement

Cardiac Resynchronization Therapy—Emerging Therapeutic Approaches

  • Neal A. Chatterjee
  • E. Kevin Heist
Arrhythmia (G Upadhyay, Section Editor)
Part of the following topical collections:
  1. Topical Collection on Arrhythmia

Abstract

Cardiac resynchronization therapy (CRT) is an important therapeutic tool in the management of patients with heart failure and electrical dyssynchrony. In appropriately selected patients, landmark randomized controlled trials have demonstrated morbidity and mortality benefit beyond standard goal-directed medical therapy. Current guidelines emphasize the greatest clinical efficacy of CRT in patients with symptomatic heart failure, left bundle branch block, and wide QRS duration (> 150 ms). Other relevant considerations include the presence of atrial fibrillation, the presence of AV block, the etiology of cardiomyopathy, the presence of masked left-sided conduction delay, and the impact of comorbidities that might predict poor clinical response. At the time of CRT implantation, key considerations include targeting of the left ventricular (LV) lead to sites of greatest electrical and/or mechanical delay, the use of quadripolar versus bipolar LV pacing leads, evaluation of multiple pacing vectors to maximize electrical resynchronization, and in select instances pre-procedure imaging of the coronary venous anatomy to help guide decision-making at the time implant. Post-implant care includes the selective use of atrio-ventricular and inter-ventricular optimization algorithms, mitigation of right ventricular pacing, recognition, and treatment of suboptimal biventricular pacing, as well as management by a multi-disciplinary team of cardiovascular specialists. Emerging therapeutic strategies for patients eligible for CRT include the use of endocardial LV pacing, novel LV pacing options including multi-point pacing, His bundle pacing, and the integration of remote monitoring platforms that may identify patients at risk for clinical worsening.

Keywords

Cardiac resynchronization therapy Heart failure Leadless pacing His bundle pacing 

Notes

Compliance with Ethical Standards

Conflict of Interest

Neal A. Chatterjee declares no potential conflicts of interest.

E. Kevin Heist reports personal fees from Boston Scientific, grants and personal fees from Biotronik, grants and personal fees from St. Jude Medical, personal fees from Medtronic, grants from LivaNova, outside the submitted work. In addition, Dr. Heist has a patent Patented LV lead pacing design issued.

Human and Animal Rights and Informed Consent

This article does not contain any studies with human or animal subjects performed by any of the authors.

References and Recommended Reading

Papers of particular interest, published recently, have been highlighted as: • Of importance •• Of major importance

  1. 1.
    Brignole M, Auricchio A, Baron-Esquivias G, Bordachar P, Boriani G, Breithardt OA, et al. 2013 ESC guidelines on cardiac pacing and cardiac resynchronization therapy: the task force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA). Europace : Eur Pacing, Arrhythmias, Card Electrophysiol : J Work Groups Card Pacing Arrhythmias Card Cell Electrophysiol Eur Soc Cardiol. 2013;15(8):1070–118.  https://doi.org/10.1093/europace/eut206.CrossRefGoogle Scholar
  2. 2.
    Epstein AE, DiMarco JP, Ellenbogen KA, Estes NA 3rd, Freedman RA, Gettes LS, et al. 2012 ACCF/AHA/HRS focused update incorporated into the ACCF/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol. 2013;61(3):e6–75.  https://doi.org/10.1016/j.jacc.2012.11.007.CrossRefPubMedGoogle Scholar
  3. 3.
    Abraham WT, Fisher WG, Smith AL, Delurgio DB, Leon AR, Loh E, et al. Cardiac resynchronization in chronic heart failure. N Engl J Med. 2002;346(24):1845–53.  https://doi.org/10.1056/NEJMoa013168.CrossRefPubMedGoogle Scholar
  4. 4.
    Bristow MR, Saxon LA, Boehmer J, Krueger S, Kass DA, De Marco T, et al. Cardiac-resynchronization therapy with or without an implantable defibrillator in advanced chronic heart failure. N Engl J Med. 2004;350(21):2140–50.  https://doi.org/10.1056/NEJMoa032423.CrossRefPubMedGoogle Scholar
  5. 5.
    Cleland JG, Daubert JC, Erdmann E, Freemantle N, Gras D, Kappenberger L, et al. The effect of cardiac resynchronization on morbidity and mortality in heart failure. N Engl J Med. 2005;352(15):1539–49.  https://doi.org/10.1056/NEJMoa050496.CrossRefPubMedGoogle Scholar
  6. 6.
    Moss AJ, Hall WJ, Cannom DS, Klein H, Brown MW, Daubert JP, et al. Cardiac-resynchronization therapy for the prevention of heart-failure events. N Engl J Med. 2009;361(14):1329–38.  https://doi.org/10.1056/NEJMoa0906431.CrossRefPubMedGoogle Scholar
  7. 7.
    Tang AS, Wells GA, Talajic M, Arnold MO, Sheldon R, Connolly S, et al. Cardiac-resynchronization therapy for mild-to-moderate heart failure. N Engl J Med. 2010;363(25):2385–95.  https://doi.org/10.1056/NEJMoa1009540.CrossRefPubMedGoogle Scholar
  8. 8.
    Mullens W, Grimm RA, Verga T, Dresing T, Starling RC, Wilkoff BL, et al. Insights from a cardiac resynchronization optimization clinic as part of a heart failure disease management program. J Am Coll Cardiol. 2009;53(9):765–73.  https://doi.org/10.1016/j.jacc.2008.11.024.CrossRefPubMedGoogle Scholar
  9. 9.
    Cleland JG, Freemantle N, Daubert JC, Toff WD, Leisch F, Tavazzi L. Long-term effect of cardiac resynchronisation in patients reporting mild symptoms of heart failure: a report from the CARE-HF study. Heart. 2008;94(3):278–83.  https://doi.org/10.1136/hrt.2007.128991.CrossRefPubMedGoogle Scholar
  10. 10.
    Linde C, Abraham WT, Gold MR, St John Sutton M, Ghio S, Daubert C. Randomized trial of cardiac resynchronization in mildly symptomatic heart failure patients and in asymptomatic patients with left ventricular dysfunction and previous heart failure symptoms. J Am Coll Cardiol. 2008;52(23):1834–43.  https://doi.org/10.1016/j.jacc.2008.08.027.CrossRefPubMedGoogle Scholar
  11. 11.
    Leclercq C, Cazeau S, Lellouche D, Fossati F, Anselme F, Davy JM, et al. Upgrading from single chamber right ventricular to biventricular pacing in permanently paced patients with worsening heart failure: the RD-CHF study. Pacing Clin Electrophysiol : PACE. 2007;30(Suppl 1):S23–30.  https://doi.org/10.1111/j.1540-8159.2007.00598.x.PubMedGoogle Scholar
  12. 12.
    Sweeney MO, Hellkamp AS, Ellenbogen KA, Greenspon AJ, Freedman RA, Lee KL, et al. Adverse effect of ventricular pacing on heart failure and atrial fibrillation among patients with normal baseline QRS duration in a clinical trial of pacemaker therapy for sinus node dysfunction. Circulation. 2003;107(23):2932–7.  https://doi.org/10.1161/01.cir.0000072769.17295.b1.CrossRefPubMedGoogle Scholar
  13. 13.
    Wilkoff BL, Cook JR, Epstein AE, Greene HL, Hallstrom AP, Hsia H, et al. Dual-chamber pacing or ventricular backup pacing in patients with an implantable defibrillator: the dual chamber and VVI implantable defibrillator (DAVID) trial. JAMA. 2002;288(24):3115–23.CrossRefPubMedGoogle Scholar
  14. 14.
    Curtis AB, Worley SJ, Adamson PB, Chung ES, Niazi I, Sherfesee L, et al. Biventricular pacing for atrioventricular block and systolic dysfunction. N Engl J Med. 2013;368(17):1585–93.  https://doi.org/10.1056/NEJMoa1210356.CrossRefPubMedGoogle Scholar
  15. 15.
    Funck RC, Blanc JJ, Mueller HH, Schade-Brittinger C, Bailleul C, Maisch B. Biventricular stimulation to prevent cardiac desynchronization: rationale, design, and endpoints of the ‘Biventricular pacing for atrioventricular block to prevent cardiac desynchronization (BioPace)’ study. Europace : Eur Pacing Arrhythmias Card Electrophysiol : J Work Groups Card Pacing Arrhythmias Card Cell Electrophysiol Eur Soc Cardiol. 2006;8(8):629–35.  https://doi.org/10.1093/europace/eul075.CrossRefGoogle Scholar
  16. 16.
    Achilli A, Sassara M, Ficili S, Pontillo D, Achilli P, Alessi C, et al. Long-term effectiveness of cardiac resynchronization therapy in patients with refractory heart failure and “narrow” QRS. J Am Coll Cardiol. 2003;42(12):2117–24.  https://doi.org/10.1016/j.jacc.2003.08.024.CrossRefPubMedGoogle Scholar
  17. 17.
    Yu CM, Chan YS, Zhang Q, Yip GW, Chan CK, Kum LC, et al. Benefits of cardiac resynchronization therapy for heart failure patients with narrow QRS complexes and coexisting systolic asynchrony by echocardiography. J Am Coll Cardiol. 2006;48(11):2251–7.  https://doi.org/10.1016/j.jacc.2006.07.054.CrossRefPubMedGoogle Scholar
  18. 18.
    Beshai JF, Grimm RA, Nagueh SF, Baker JH 2nd, Beau SL, Greenberg SM, et al. Cardiac-resynchronization therapy in heart failure with narrow QRS complexes. N Engl J Med. 2007;357(24):2461–71.  https://doi.org/10.1056/NEJMoa0706695.CrossRefPubMedGoogle Scholar
  19. 19.
    Ruschitzka F, Abraham WT, Singh JP, Bax JJ, Borer JS, Brugada J, et al. Cardiac-resynchronization therapy in heart failure with a narrow QRS complex. N Engl J Med. 2013;369(15):1395–405.  https://doi.org/10.1056/NEJMoa1306687.CrossRefPubMedGoogle Scholar
  20. 20.
    Thibault B, Harel F, Ducharme A, White M, Ellenbogen KA, Frasure-Smith N, et al. Cardiac resynchronization therapy in patients with heart failure and a QRS complex <120 milliseconds: the evaluation of resynchronization therapy for heart failure (LESSER-EARTH) trial. Circulation. 2013;127(8):873–81.  https://doi.org/10.1161/circulationaha.112.001239.CrossRefPubMedGoogle Scholar
  21. 21.
    Kandala J, Altman RK, Park MY, Singh JP. Clinical, laboratory, and pacing predictors of CRT response. J Cardiovasc Transl Res. 2012;5(2):196–212.  https://doi.org/10.1007/s12265-012-9352-0.CrossRefPubMedGoogle Scholar
  22. 22.
    Fornwalt BK, Sprague WW, BeDell P, Suever JD, Gerritse B, Merlino JD, et al. Agreement is poor among current criteria used to define response to cardiac resynchronization therapy. Circulation. 2010;121(18):1985–91.  https://doi.org/10.1161/circulationaha.109.910778.CrossRefPubMedPubMedCentralGoogle Scholar
  23. 23.
    Yu CM, Bleeker GB, Fung JW, Schalij MJ, Zhang Q, van der Wall EE, et al. Left ventricular reverse remodeling but not clinical improvement predicts long-term survival after cardiac resynchronization therapy. Circulation. 2005;112(11):1580–6.  https://doi.org/10.1161/circulationaha.105.538272.CrossRefPubMedGoogle Scholar
  24. 24.
    Hsu JC, Solomon SD, Bourgoun M, McNitt S, Goldenberg I, Klein H, et al. Predictors of super-response to cardiac resynchronization therapy and associated improvement in clinical outcome: the MADIT-CRT (multicenter automatic defibrillator implantation trial with cardiac resynchronization therapy) study. J Am Coll Cardiol. 2012;59(25):2366–73.  https://doi.org/10.1016/j.jacc.2012.01.065.CrossRefPubMedGoogle Scholar
  25. 25.
    Auricchio A, Fantoni C, Regoli F, Carbucicchio C, Goette A, Geller C, et al. Characterization of left ventricular activation in patients with heart failure and left bundle-branch block. Circulation. 2004;109(9):1133–9.  https://doi.org/10.1161/01.cir.0000118502.91105.f6.CrossRefPubMedGoogle Scholar
  26. 26.
    Sipahi I, Chou JC, Hyden M, Rowland DY, Simon DI, Fang JC. Effect of QRS morphology on clinical event reduction with cardiac resynchronization therapy: meta-analysis of randomized controlled trials. Am Heart J. 2012;163(2):260–7.e3.  https://doi.org/10.1016/j.ahj.2011.11.014.CrossRefPubMedPubMedCentralGoogle Scholar
  27. 27.
    • Biton Y, Kutyifa V, Cygankiewicz I, Goldenberg I, Klein H, McNitt S, et al. Relation of QRS duration to clinical benefit of cardiac resynchronization therapy in mild heart failure patients without left bundle branch block: the multicenter automatic defibrillator implantation trial with cardiac resynchronization therapy substudy. Circ Heart Fail. 2016;9(2):e002667.  https://doi.org/10.1161/circheartfailure.115.002667. This study is a post-hoc analysis of the randomized MADIT-CRT trial and identifies a subset of patients with non-left bundle branch block who may benefit from CRT.PubMedGoogle Scholar
  28. 28.
    Fantoni C, Kawabata M, Massaro R, Regoli F, Raffa S, Arora V, et al. Right and left ventricular activation sequence in patients with heart failure and right bundle branch block: a detailed analysis using three-dimensional non-fluoroscopic electroanatomic mapping system. J Cardiovasc Electrophysiol. 2005;16(2):112–9; discussion 20-1.  https://doi.org/10.1046/j.1540-8167.2005.40777.x.
  29. 29.
    Richman JL, Wolff L. Left bundle branch block masquerading as right bundle branch block. Am Heart J. 1954;47(3):383–93.  https://doi.org/10.1016/0002-8703(54)90295-1.CrossRefPubMedGoogle Scholar
  30. 30.
    Sundaram V, Sahadevan J, Waldo AL, Stukenborg GJ, Reddy YNV, Asirvatham SJ, et al. Implantable cardioverter-defibrillators with versus without resynchronization therapy in patients with a QRS duration >180 ms. J Am Coll Cardiol. 2017;69(16):2026–36.  https://doi.org/10.1016/j.jacc.2017.02.042.CrossRefPubMedGoogle Scholar
  31. 31.
    Upadhyay GA, Choudhry NK, Auricchio A, Ruskin J, Singh JP. Cardiac resynchronization in patients with atrial fibrillation: a meta-analysis of prospective cohort studies. J Am Coll Cardiol. 2008;52(15):1239–46.  https://doi.org/10.1016/j.jacc.2008.06.043.CrossRefPubMedGoogle Scholar
  32. 32.
    Wilton SB, Leung AA, Ghali WA, Faris P, Exner DV. Outcomes of cardiac resynchronization therapy in patients with versus those without atrial fibrillation: a systematic review and meta-analysis. Heart Rhythm : Off J Heart Rhythm Soc. 2011;8(7):1088–94.  https://doi.org/10.1016/j.hrthm.2011.02.014.CrossRefGoogle Scholar
  33. 33.
    Healey JS, Hohnloser SH, Exner DV, Birnie DH, Parkash R, Connolly SJ, et al. Cardiac resynchronization therapy in patients with permanent atrial fibrillation: results from the resynchronization for ambulatory heart failure trial (RAFT). Circ Heart Fail. 2012;5(5):566–70.  https://doi.org/10.1161/circheartfailure.112.968867.CrossRefPubMedGoogle Scholar
  34. 34.
    Yin J, Hu H, Wang Y, Xue M, Li X, Cheng W, et al. Effects of atrioventricular nodal ablation on permanent atrial fibrillation patients with cardiac resynchronization therapy: a systematic review and meta-analysis. Clin Cardiol. 2014;37(11):707–15.  https://doi.org/10.1002/clc.22312.CrossRefPubMedGoogle Scholar
  35. 35.
    Barsheshet A, Goldenberg I, Moss AJ, Eldar M, Huang DT, McNitt S, et al. Response to preventive cardiac resynchronization therapy in patients with ischaemic and nonischaemic cardiomyopathy in MADIT-CRT. Eur Heart J. 2011;32(13):1622–30.  https://doi.org/10.1093/eurheartj/ehq407.CrossRefPubMedGoogle Scholar
  36. 36.
    • Chatterjee NA, Roka A, Lubitz SA, Gold MR, Daubert C, Linde C, et al. Reduced appropriate implantable cardioverter-defibrillator therapy after cardiac resynchronization therapy-induced left ventricular function recovery: a meta-analysis and systematic review. Eur Heart J. 2015;36(41):2780–9.  https://doi.org/10.1093/eurheartj/ehv373. This study demonstrates the impact of CRT-associated reverse remodeling on a decreased risk of ventricular arrhythmia.CrossRefPubMedPubMedCentralGoogle Scholar
  37. 37.
    Kober L, Thune JJ, Nielsen JC, Haarbo J, Videbaek L, Korup E, et al. Defibrillator implantation in patients with nonischemic systolic heart failure. N Engl J Med. 2016;375(13):1221–30.  https://doi.org/10.1056/NEJMoa1608029.CrossRefPubMedGoogle Scholar
  38. 38.
    Barra S, Boveda S, Providencia R, Sadoul N, Duehmke R, Reitan C, et al. Adding defibrillation therapy to cardiac resynchronization on the basis of the myocardial substrate. J Am Coll Cardiol. 2017;69(13):1669–78.  https://doi.org/10.1016/j.jacc.2017.01.042.CrossRefPubMedGoogle Scholar
  39. 39.
    Fung JW, Szeto CC, Chan JY, Zhang Q, Chan HC, Yip GW, et al. Prognostic value of renal function in patients with cardiac resynchronization therapy. Int J Cardiol. 2007;122(1):10–6.  https://doi.org/10.1016/j.ijcard.2006.11.015.CrossRefPubMedGoogle Scholar
  40. 40.
    Garg N, Thomas G, Jackson G, Rickard J, Nally JV Jr, Tang WH, et al. Cardiac resynchronization therapy in CKD: a systematic review. Clin J Am Soc Nephrol : CJASN. 2013;8(8):1293–303.  https://doi.org/10.2215/cjn.00750113.CrossRefPubMedPubMedCentralGoogle Scholar
  41. 41.
    Chatterjee NA, Upadhyay GA, Singal G, Parks KA, Dec GW, Singh JP, et al. Pre-capillary pulmonary hypertension and right ventricular dilation predict clinical outcome in cardiac resynchronization therapy. JACC Heart Fail. 2014;2(3):230–7.  https://doi.org/10.1016/j.jchf.2014.02.004.CrossRefPubMedGoogle Scholar
  42. 42.
    Adelstein EC, Saba S. Scar burden by myocardial perfusion imaging predicts echocardiographic response to cardiac resynchronization therapy in ischemic cardiomyopathy. Am Heart J. 2007;153(1):105–12.  https://doi.org/10.1016/j.ahj.2006.10.015.CrossRefPubMedGoogle Scholar
  43. 43.
    Bilchick KC, Kuruvilla S, Hamirani YS, Ramachandran R, Clarke SA, Parker KM, et al. Impact of mechanical activation, scar, and electrical timing on cardiac resynchronization therapy response and clinical outcomes. J Am Coll Cardiol. 2014;63(16):1657–66.  https://doi.org/10.1016/j.jacc.2014.02.533.CrossRefPubMedPubMedCentralGoogle Scholar
  44. 44.
    • Zeitler EP, Friedman DJ, Daubert JP, Al-Khatib SM, Solomon SD, Biton Y, et al. Multiple comorbidities and response to cardiac resynchronization therapy: MADIT-CRT long-term follow-up. J Am Coll Cardiol. 2017;69(19):2369–79.  https://doi.org/10.1016/j.jacc.2017.03.531. This study examines the impact of comorbidites on the efficacy of CRT.CrossRefPubMedGoogle Scholar
  45. 45.
    Yancy CW, Jessup M, Bozkurt B, Butler J, Casey DE Jr, Colvin MM, et al. 2017 ACC/AHA/HFSA focused update of the 2013 ACCF/AHA guideline for the Management of Heart Failure: a report of the American College of Cardiology/American Heart Association task force on clinical practice guidelines and the Heart Failure Society of America. J Am Coll Cardiol. 2017;70(6):776–803.  https://doi.org/10.1016/j.jacc.2017.04.025.CrossRefPubMedGoogle Scholar
  46. 46.
    Derval N, Steendijk P, Gula LJ, Deplagne A, Laborderie J, Sacher F, et al. Optimizing hemodynamics in heart failure patients by systematic screening of left ventricular pacing sites: the lateral left ventricular wall and the coronary sinus are rarely the best sites. J Am Coll Cardiol. 2010;55(6):566–75.  https://doi.org/10.1016/j.jacc.2009.08.045.CrossRefPubMedGoogle Scholar
  47. 47.
    Singh JP, Klein HU, Huang DT, Reek S, Kuniss M, Quesada A, et al. Left ventricular lead position and clinical outcome in the multicenter automatic defibrillator implantation trial-cardiac resynchronization therapy (MADIT-CRT) trial. Circulation. 2011;123(11):1159–66.  https://doi.org/10.1161/circulationaha.110.000646.CrossRefPubMedGoogle Scholar
  48. 48.
    Gold MR, Yu Y, Singh JP, Stein KM, Birgersdotter-Green U, Meyer TE, et al. The effect of left ventricular electrical delay on AV optimization for cardiac resynchronization therapy. Heart Rhythm : Off J Heart Rhythm Soc. 2013;10(7):988–93.  https://doi.org/10.1016/j.hrthm.2013.03.009.CrossRefGoogle Scholar
  49. 49.
    Singh JP, Fan D, Heist EK, Alabiad CR, Taub C, Reddy V, et al. Left ventricular lead electrical delay predicts response to cardiac resynchronization therapy. Heart Rhythm : Off J Heart Rhythm Soc. 2006;3(11):1285–92.  https://doi.org/10.1016/j.hrthm.2006.07.034.CrossRefGoogle Scholar
  50. 50.
    Duckett SG, Ginks M, Shetty AK, Bostock J, Gill JS, Hamid S, et al. Invasive acute hemodynamic response to guide left ventricular lead implantation predicts chronic remodeling in patients undergoing cardiac resynchronization therapy. J Am Coll Cardiol. 2011;58(11):1128–36.  https://doi.org/10.1016/j.jacc.2011.04.042.CrossRefPubMedGoogle Scholar
  51. 51.
    Ellenbogen KA, Gold MR, Meyer TE, Fernndez Lozano I, Mittal S, Waggoner AD, et al. Primary results from the SmartDelay determined AV optimization: a comparison to other AV delay methods used in cardiac resynchronization therapy (SMART-AV) trial: a randomized trial comparing empirical, echocardiography-guided, and algorithmic atrioventricular delay programming in cardiac resynchronization therapy. Circulation. 2010;122(25):2660–8.  https://doi.org/10.1161/circulationaha.110.992552.CrossRefPubMedGoogle Scholar
  52. 52.
    CRT Implant Strategy Using the Longest Electrical Delay for Non-left Bundle Branch Block Patients (ENHANCE CRT). Accessed 6 Oct 2014 at http://clinicaltrials.gov/show/NCT01983293.
  53. 53.
    Rinaldi CA, Burri H, Thibault B, Curnis A, Rao A, Gras D, et al. A review of multisite pacing to achieve cardiac resynchronization therapy. Europace: Eur Pacing Arrhythmias Cardiac Electrophysiol : J Work Groups Card Pacing Arrhythm Card Cell Electrophysiol Eur Soc Cardiol. 2014;  https://doi.org/10.1093/europace/euu197.
  54. 54.
    • Pappone C, Calovic Z, Vicedomini G, Cuko A, McSpadden LC, Ryu K, et al. Multipoint left ventricular pacing improves acute hemodynamic response assessed with pressure-volume loops in cardiac resynchronization therapy patients. Heart rhythm : Off J Heart Rhythm Soc. 2014;11(3):394–401.  https://doi.org/10.1016/j.hrthm.2013.11.023. This study demonstrates the acute hemodynamic benefits of multi-point pacing in CRT.CrossRefGoogle Scholar
  55. 55.
    Pappone C, Calovic Z, Vicedomini G, Cuko A, McSpadden LC, Ryu K, et al. Multipoint left ventricular pacing in a single coronary sinus branch improves mid-term echocardiographic and clinical response to cardiac resynchronization therapy. J Cardiovasc Electrophysiol. 2014;26(1):58–63.  https://doi.org/10.1111/jce.12513.CrossRefPubMedGoogle Scholar
  56. 56.
    Tomassoni G, Baker J 2nd, Corbisiero R, Love C, Martin D, Sheppard R, et al. Rationale and design of a randomized trial to assess the safety and efficacy of MultiPoint Pacing (MPP) in cardiac resynchronization therapy: The MPP Trial. Ann Noninvasive Electrocardiol : Off J Int Soc Holter Noninvasive Electrocardiol Inc. 2017;  https://doi.org/10.1111/anec.12448.
  57. 57.
    MOre REsponse on Cardiac Resynchronization Therapy With MultiPoint Pacing (MORE-CRT MPP). http://clinicaltrials.gov/show/NCT02006069. Accessed 6 Oct 2014 at http://clinicaltrials.gov/show/NCT02006069.
  58. 58.
    Auricchio A, Stellbrink C, Block M, Sack S, Vogt J, Bakker P, et al. Effect of pacing chamber and atrioventricular delay on acute systolic function of paced patients with congestive heart failure. The pacing therapies for congestive heart failure study group. The Guidant congestive heart failure research group. Circulation. 1999;99(23):2993–3001.  https://doi.org/10.1161/01.CIR.99.23.2993.CrossRefPubMedGoogle Scholar
  59. 59.
    Gras D, Gupta MS, Boulogne E, Guzzo L, Abraham WT. Optimization of AV and VV delays in the real-world CRT patient population: an international survey on current clinical practice. Pacing Clin Electrophysiol : PACE. 2009;32(Suppl 1):S236–9.  https://doi.org/10.1111/j.1540-8159.2008.02294.x.CrossRefPubMedGoogle Scholar
  60. 60.
    Barold SS, Ilercil A, Herweg B. Echocardiographic optimization of the atrioventricular and interventricular intervals during cardiac resynchronization. Europace : Eur Pacing Arrhythmias Card Electrophysiol : J Work Groups Card Pacing Arrhythmias Card Cell Electrophysiol Eur Soc Cardiol. 2008;10(Suppl 3):iii88–95.  https://doi.org/10.1093/europace/eun220.Google Scholar
  61. 61.
    Kamdar R, Frain E, Warburton F, Richmond L, Mullan V, Berriman T, et al. A prospective comparison of echocardiography and device algorithms for atrioventricular and interventricular interval optimization in cardiac resynchronization therapy. Europace : Eur Pacing Arrhythmias Card Electrophysiol : J Work Groups Card Pacing Arrhythmias Card Cell Electrophysiol Eur Soc Cardiol. 2010;12(1):84–91.  https://doi.org/10.1093/europace/eup337.CrossRefGoogle Scholar
  62. 62.
    Singh JP, Abraham WT, Chung ES, Rogers T, Sambelashvili A, Coles JA Jr, et al. Clinical response with adaptive CRT algorithm compared with CRT with echocardiography-optimized atrioventricular delay: a retrospective analysis of multicentre trials. Europace : Eur Pacing Arrhythmias Card Electrophysiol : J Work Groups Card Pacing Arrhythmias Card Cell Electrophysiol Euro Soc Cardiol. 2013;15(11):1622–8.  https://doi.org/10.1093/europace/eut107.CrossRefGoogle Scholar
  63. 63.
    Boriani G, Biffi M, Muller CP, Seidl KH, Grove R, Vogt J, et al. A prospective randomized evaluation of VV delay optimization in CRT-D recipients: echocardiographic observations from the RHYTHM II ICD study. Pacing Clin Electrophysiol : PACE. 2009;32(Suppl 1):S120–5.  https://doi.org/10.1111/j.1540-8159.2008.02267.x.CrossRefPubMedGoogle Scholar
  64. 64.
    Leon AR, Abraham WT, Brozena S, Daubert JP, Fisher WG, Gurley JC, et al. Cardiac resynchronization with sequential biventricular pacing for the treatment of moderate-to-severe heart failure. J Am Coll Cardiol. 2005;46(12):2298–304.  https://doi.org/10.1016/j.jacc.2005.08.032.CrossRefPubMedGoogle Scholar
  65. 65.
    Marsan NA, Bleeker GB, Van Bommel RJ, Borleffs C, Bertini M, Holman ER, et al. Cardiac resynchronization therapy in patients with ischemic versus non-ischemic heart failure: differential effect of optimizing interventricular pacing interval. Am Heart J. 2009;158(5):769–76.  https://doi.org/10.1016/j.ahj.2009.09.004.CrossRefPubMedGoogle Scholar
  66. 66.
    Martin DO, Lemke B, Birnie D, Krum H, Lee KL, Aonuma K, et al. Investigation of a novel algorithm for synchronized left-ventricular pacing and ambulatory optimization of cardiac resynchronization therapy: results of the adaptive CRT trial. Heart Rhythm : Off J Heart Rhythm Soc. 2012;9(11):1807–14.  https://doi.org/10.1016/j.hrthm.2012.07.009.CrossRefGoogle Scholar
  67. 67.
    Birnie D, Lemke B, Aonuma K, Krum H, Lee KL, Gasparini M, et al. Clinical outcomes with synchronized left ventricular pacing: analysis of the adaptive CRT trial. Heart Rhythm : Off J Heart Rhythm Soc. 2013;10(9):1368–74.  https://doi.org/10.1016/j.hrthm.2013.07.007.CrossRefGoogle Scholar
  68. 68.
    Filippatos G, Birnie D, Gold MR, Gerritse B, Hersi A, Jacobs S, et al. Rationale and design of the AdaptResponse trial: a prospective randomized study of cardiac resynchronization therapy with preferential adaptive left ventricular-only pacing. Eur J Heart Fail. 2017;19(7):950–7.  https://doi.org/10.1002/ejhf.895.CrossRefPubMedPubMedCentralGoogle Scholar
  69. 69.
    • Boriani G, Da Costa A, Quesada A, Ricci RP, Favale S, Boscolo G, et al. Effects of remote monitoring on clinical outcomes and use of healthcare resources in heart failure patients with biventricular defibrillators: results of the MORE-CARE multicentre randomized controlled trial. Eur J Heart Fail. 2017;19(3):416–25.  https://doi.org/10.1002/ejhf.626. This study examines the impact of remote monitoring platforms on healthcare utilization for patients undergoing CRT.CrossRefPubMedGoogle Scholar
  70. 70.
    Hayes DL, Boehmer JP, Day JD, Gilliam FR 3rd, Heidenreich PA, Seth M, et al. Cardiac resynchronization therapy and the relationship of percent biventricular pacing to symptoms and survival. Heart Rhythm : Off J Heart Rhythm Soc. 2011;8(9):1469–75.  https://doi.org/10.1016/j.hrthm.2011.04.015.CrossRefGoogle Scholar
  71. 71.
    Cheng A, Landman SR, Stadler RW. Reasons for loss of cardiac resynchronization therapy pacing: insights from 32 844 patients. Circ Arrhythmia Electrophysiol. 2012;5(5):884–8.  https://doi.org/10.1161/circep.112.973776.CrossRefGoogle Scholar
  72. 72.
    Altman RK, Parks KA, Schlett CL, Orencole M, Park MY, Truong QA, et al. Multidisciplinary care of patients receiving cardiac resynchronization therapy is associated with improved clinical outcomes. Eur Heart J. 2012;33(17):2181–8.  https://doi.org/10.1093/eurheartj/ehs107.CrossRefPubMedPubMedCentralGoogle Scholar
  73. 73.
    Kamath GS, Balaram S, Choi A, Kuteyeva O, Garikipati NV, Steinberg JS, et al. Long-term outcome of leads and patients following robotic epicardial left ventricular lead placement for cardiac resynchronization therapy. Pacing Clin Electrophysiol : PACE. 2011;34(2):235–40.  https://doi.org/10.1111/j.1540-8159.2010.02943.x.CrossRefPubMedGoogle Scholar
  74. 74.
    van Dijk VF, Fanggiday J, Balt JC, Wijffels M, Daeter EJ, Kelder JC, et al. Effects of epicardial versus transvenous left ventricular lead placement on left ventricular function and cardiac perfusion in cardiac resynchronization therapy: a randomized clinical trial. J Cardiovasc Electrophysiol. 2017;28(8):917–23.  https://doi.org/10.1111/jce.13242.CrossRefPubMedGoogle Scholar
  75. 75.
    Auricchio A, Delnoy PP, Butter C, Brachmann J, Van Erven L, Spitzer S, et al. Feasibility, safety, and short-term outcome of leadless ultrasound-based endocardial left ventricular resynchronization in heart failure patients: results of the wireless stimulation Endocardially for CRT (WiSE-CRT) study. Europace : Eur Pacing Arrhythmias Card Electrophysiol : J Work Groups Card Pacing Arrhythmias Card Cell Electrophysiol Eur Soc Cardiol. 2014;16(5):681–8.  https://doi.org/10.1093/europace/eut435.CrossRefGoogle Scholar
  76. 76.
    Shetty AK, Sohal M, Chen Z, Ginks MR, Bostock J, Amraoui S, et al. A comparison of left ventricular endocardial, multisite, and multipolar epicardial cardiac resynchronization: an acute haemodynamic and electroanatomical study. Europace : Eur Pacing Arrhythmias Card Electrophysiol : J Work Groups Card Pacing Arrhythmias Card Cell Electrophysiol Eur Soc Cardiol. 2014;16(6):873–9.  https://doi.org/10.1093/europace/eut420.CrossRefGoogle Scholar
  77. 77.
    ALternate Site Cardiac ReSYNChronization (ALSYNC) Study. http://clinicaltrials.gov/show/NCT01277783. Accessed 6 Oct 2014 at http://clinicaltrials.gov/show/NCT01277783.
  78. 78.
    •• Reddy VY, Miller MA, Neuzil P, Sogaard P, Butter C, Seifert M, et al. Cardiac resynchronization therapy with wireless left ventricular endocardial pacing: the SELECT-LV study. J Am Coll Cardiol. 2017;69(17):2119–29.  https://doi.org/10.1016/j.jacc.2017.02.059. This study demonstrates the feasability of endocardial LV pacing in CRT-eligible patients.CrossRefPubMedGoogle Scholar
  79. 79.
    Vijayaraman P, Bordachar P, Ellenbogen KA. The continued search for physiological pacing: where are we now? J Am Coll Cardiol. 2017;69(25):3099–114.  https://doi.org/10.1016/j.jacc.2017.05.005.CrossRefPubMedGoogle Scholar
  80. 80.
    •• Ajijola OA, Upadhyay GA, Macias C, Shivkumar K, Tung R. Permanent his-bundle pacing for cardiac resynchronization therapy: initial feasibility study in lieu of left ventricular lead. Heart Rhythm : Off J Heart Rhythm Soc. 2017;14(9):1353–61.  https://doi.org/10.1016/j.hrthm.2017.04.003. This study examines the impact of his bundle pacing on CRT-eligible patients and demonstrates narrowing of left bundle branch block in a majority.CrossRefGoogle Scholar
  81. 81.
    • Boehmer JP, Hariharan R, Devecchi FG, Smith AL, Molon G, Capucci A, et al. A multisensor algorithm predicts heart failure events in patients with implanted devices: results from the MultiSENSE study. JACC Heart failure. 2017;5(3):216–25.  https://doi.org/10.1016/j.jchf.2016.12.011. This study examines the impact of a multi-sensor algorithm to predict incident clinical worsening with a lead time of 30 days.CrossRefPubMedGoogle Scholar

Copyright information

© Springer Science+Business Media, LLC, part of Springer Nature 2018

Authors and Affiliations

  1. 1.Cardiology Division and Cardiac Arrhythmia Service, Massachusetts General HospitalHarvard Medical SchoolBostonUSA
  2. 2.Cardiology Division of the Department of Medicine, Massachusetts General HospitalHarvard Medical SchoolBostonUSA

Personalised recommendations