Ultrasonic Cleaning-Induced Failures in Medical Devices

  • Technical Article---Peer-Reviewed
  • Published:
Journal of Failure Analysis and Prevention Aims and scope Submit manuscript

Abstract

Ultrasonic cleaning is often used as part of the manufacturing process of small medical devices such as guide wires and vascular implants. Ultrasonic cleaning at frequencies close to the natural frequency of the device can result in resonance, resulting in significant mechanical damage and possibly premature failure. This paper provides case studies of ultrasonic cleaning-induced fatigue and corresponding failures in small medical devices. Preventative measures, including analytical tools such as finite element analysis (FEA), to ensure that ultrasonic cleaning frequencies do not result in resonance and stresses sufficient to cause fatigue damage are also discussed.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13

Similar content being viewed by others

References

  1. Mallette, L.A., Chen, I., Johnson, T.W.: A case study in ultrasonic cleaning damage. IEEE Aerospace Conf. 3(21–28), 77–80 (1998)

    Google Scholar 

  2. Yuqi, J., Dong, T., Xianzhong, S., Fai, L.: The effect of ultrasonic cleaning on the bond wires, Proceedings of the 12th IPFA, 2005, Singapore, IEEE, pp. 237–241

  3. Marrey, R.V., Burgermeister, R., Grishaber, R.B., Ritchie, R.O.: Fatigue life and prediction for cobalt-chromium stents: a fracture mechanics analysis. Biomaterials 27, 1988–2000 (2006)

    Article  CAS  PubMed  Google Scholar 

  4. Timoshenko, S., Young, D.H., Weaver, W.: Vibration Problems in Engineering, 4th edn. Wiley, New York (1974)

    Google Scholar 

  5. Handbook of Silicon Wafer Cleaning Technology, 2nd edn. In: Reinhardt, K.A., Kern, W. (eds.). William Andrews Publishing (2008)

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to B. A. James.

Rights and permissions

Reprints and permissions

About this article

Cite this article

James, B.A., McVeigh, C., Rosenbloom, S.N. et al. Ultrasonic Cleaning-Induced Failures in Medical Devices. J Fail. Anal. and Preven. 10, 223–227 (2010). https://doi.org/10.1007/s11668-010-9339-6

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11668-010-9339-6

Keywords

Navigation