Advertisement

LO SCALPELLO-OTODI Educational

, Volume 32, Issue 1, pp 18–21 | Cite as

La protesizzazione nelle fratture laterali del femore prossimale

  • Francesco Benazzo
  • Loris Perticarini
Aggiornamenti

Total hip replacement in the treatment of extracapsular hip fractures

Abstract

In case of extracapsular hip fractures, whatever the anatomic type, internal fixation is currently the standard approach. Hip conical modular implants are an excellent alternative to osteosynthesis in old patients with unstable trochanteric fractures, rheumatoid arthritis or end-stage osteoarthritis with substantial hip symptoms before fracture, or like rescue procedure in the failure of osteosynthesis.

Notes

Conflitto di interesse

Gli autori Francesco Benazzo e Loris Perticarini hanno partecipato allo sviluppo dello stelo protesico oggetto dello studio clinico.

Consenso informato e conformità agli standard etici

Tutte le procedure descritte nello studio e che hanno coinvolto esseri umani sono state attuate in conformità alle norme etiche stabilite dalla dichiarazione di Helsinki del 1975 e successive modifiche. Il consenso informato è stato ottenuto da tutti i pazienti inclusi nello studio.

Human and animal rights

L’articolo non contiene alcuno studio eseguito su esseri umani e su animali da parte degli autori.

Bibliografia

  1. 1.
    Stern R (2007) Are there advances in the treatment of extracapsular hip fractures in the elderly? Injury 38(Suppl 3):77–87 CrossRefGoogle Scholar
  2. 2.
    Aguado-Maestro I, Panteli M, García-Alonso M et al. (2017) Hip osteoarthritis as a predictor of the fracture pattern in proximal femur fractures. Injury 48:S41–S46 CrossRefPubMedGoogle Scholar
  3. 3.
    Zottola V, Bonelli C, Foti A, Consonni O (2015) L’utilizzo della protesi d’anca nel trattamento delle fratture del femore prossimale. Lo Scalpello 29(3):192–198 CrossRefGoogle Scholar
  4. 4.
    Thakur RR, Deshmukh AJ, Goyal A et al. (2011) Management of failed trochanteric fracture fixation with cementless modular hip arthroplasty using a distally fixing stem. J Arthroplast 26(3):398–403 CrossRefGoogle Scholar
  5. 5.
    Weiss RJ, Kärrholm J, Hailer NP et al. (2012) Salvage of failed trochanteric and subtrochanteric fractures using a distally fixed, modular, uncemented hip revision stem 30 patients followed for a mean of 4 years. Acta Orthop 83(5):488–492 CrossRefPubMedPubMedCentralGoogle Scholar
  6. 6.
    Chirodian N, Arch B, Parker MJ (2005) Sliding hip screw fixation of trochanteric hip fractures: outcome of 1024 procedures. Injury 36(6):793–800 CrossRefPubMedGoogle Scholar
  7. 7.
    Abouelela A (2012) Salvage of failed trochanteric fracture fixation using the revitan curved cementless modular hip arthroplasty. J Arthroplast 27(7):1382–1388 CrossRefGoogle Scholar
  8. 8.
    Blomfeldt R, Törnkvist H, Ponzer S et al. (2006) Displaced femoral neck fracture: comparison of primary total hip replacement with secondary replacement after failed internal fixation. Acta Orthop 77(4):638–643 CrossRefPubMedGoogle Scholar
  9. 9.
    Hossain M, Andrew JG (2012) Is there a difference in perioperative mortality between cemented and uncemented implants in hip fracture surgery? Injury 43(12):2161–2164 CrossRefPubMedGoogle Scholar
  10. 10.
    Mortazavi SM, Greenky MR, Bican O et al. (2012) Total hip arthroplasty after prior surgical treatment of hip fracture—is it always challenging? J Arthroplast 27(1):31–36 CrossRefGoogle Scholar

Copyright information

© Società Italiana Ortopedici Traumatologi Ospedalieri d’Italia 2018

Authors and Affiliations

  1. 1.Ortopedia e TraumatologiaFondazione IRCCS Policlinico San MatteoPaviaItalia

Personalised recommendations