Abstract
Purpose
We evaluated the associations between gestational age (GA) and lung-to-liver signal intensity ratio (LLSIR) and fetal lung volume (FLV) using magnetic resonance imaging (MRI). Moreover, we evaluated the reproducibility of these measurements.
Materials and methods
LLSIR and FLV were measured using single-shot fast spin-echo MRI in 88 consecutive fetuses. The Spearman test was used to assess the relationships between (1) LLSIR and GA, and (2) FLV and GA in 81 fetuses without lung abnormalities. Intra- and inter-observer reliabilities were assessed using intra-class correlation coefficients (ICCs).
Results
Overall, GA and LLSIR were significantly correlated (r = 0.62, p < 0.001). However, GA and LLSIR were only significantly correlated during the third trimester (before third trimester: r = 0.39, p = 0.08; during third trimester: r = 0.46, p < 0.001). Overall, GA and FLV were significantly correlated (r = 0.72, p < 0.001). FLV was significantly correlated with GA before (r = 0.86, p < 0.001) and during the third trimester (r = 0.47, p < 0.001). All ICCs were above 0.90.
Conclusions
LLSIR and FLV are useful for the assessment of fetal lung maturity and are highly reproducible. Before the third trimester, FLV is more suitable than LLSIR for the evaluation of fetal lung maturity.
Similar content being viewed by others
References
Oka Y, Rahman M, Sasakura C, Waseda T, Watanabe Y, Fujii R, et al. Prenatal diagnosis of fetal respiratory function: evaluation of fetal lung maturity using lung-to-liver signal intensity ratio at magnetic resonance imaging. Prenat Diagn. 2014;34:1289–94.
O’Brien WF, Cefalo RC. Clinical applicability of amniotic fluid tests for fetal pulmonic maturity. Am J Obstet Gynecol. 1980;136:135–44.
Rubesova E. Why do we need more data on MR volumetric measurements of the fetal lung? Pediatr Radiol. 2016;46:167–71.
Jaffe TA, Miller CM, Merkle EM. Practice patterns in imaging of the pregnant patient with abdominal pain: a survey of academic centers. AJR Am J Roentgenol. 2007;189:1128–34.
Ray JG, Vermeulen MJ, Bharatha A, Montanera WJ, Park AL. Association between MRI exposure during pregnancy and fetal and childhood outcomes. JAMA. 2016;316:952–61.
Moshiri M, Mannelli L, Richardson ML, Bhargava P, Dubinsky TJ. Fetal lung maturity assessment with MRI fetal lung-to-liver signal-intensity ratio. AJR Am J Roentgenol. 2013;201:1386–90.
Kasprian G, Balassy C, Brugger PC, Prayer D. MRI of normal and pathological fetal lung development. Eur J Radiol. 2006;57:261–70.
Kuwashima S, Nishimura G, Iimura F, Kohno T, Watanabe H, Kohno A, et al. Low-intensity fetal lungs on MRI may suggest the diagnosis of pulmonary hypoplasia. Pediatr Radiol. 2001;31:669–72.
Paek BW, Coakley FV, Lu Y, Filly RA, Lopoo JB, Qayyum A. Congenital diaphragmatic hernia: prenatal evaluation with MR lung volumetry—preliminary experience. Radiology. 2001;220:63–7.
Brewerton LJ, Chari RS, Liang Y, Bhargava R. Fetal lung-to-liver signal intensity ratio at MR imaging: development of a normal scale and possible role in predicting pulmonary hypoplasia in utero. Radiology. 2005;235:1005–10.
van der Vorst JR, van Dam RM, van Stiphout RS, van den Broek MA, Hollander IH, Kessels AG, et al. Virtual liver resection and volumetric analysis of the future liver remnant using open source image processing software. World J Surg. 2010;34:2426–33.
Ward VL, Nishino M, Hatabu H, Estroff JA, Barnewolt CE, Feldman HA, et al. Fetal lung volume measurements: determination with MR imaging—effect of various factors. Radiology. 2006;240:187–93.
Keller TM, Rake A, Michel SC, Seifert B, Wisser J, Marincek B, et al. MR assessment of fetal lung development using lung volumes and signal intensities. Eur Radiol. 2004;14:984–9.
Osada H, Kaku K, Masuda K, Iitsuka Y, Seki K, Sekiya S. Quantitative and qualitative evaluations of fetal lung with MR imaging. Radiology. 2004;231:887–92.
Mills M, Winter TC, Kennedy AM, Woodward PJ. Determination of fetal lung maturity using magnetic resonance imaging signal intensity measurements. Ultrasound Q. 2014;30:61–7.
Laudy JA, Wladimiroff JW. The fetal lung. 1: developmental aspects. Ultrasound Obstet Gynecol. 2000;16:284–90.
Dubinsky TJ, Moshiri M, Adams Waldorf K, Wilson G, Maki JH, Hippe DS. Increased fetal lung T2 signal is not due to increasing surfactant concentration: an in vitro T2 mapping analysis. Prenat Diagn. 2017;37:211–4.
Duncan KR, Gowland PA, Moore RJ, Baker PN, Johnson IR. Assessment of fetal lung growth in utero with echo-planar MR imaging. Radiology. 1999;210:197–200.
Deshmukh S, Rubesova E, Barth R. MR assessment of normal fetal lung volumes: a literature review. AJR Am J Roentgenol. 2010;194:W212–7.
Rypens F, Metens T, Rocourt N, Sonigo P, Brunelle F, Quere MP. Fetal lung volume: estimation at MR imaging-initial results. Radiology. 2001;219:236–41.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that there is no conflict of interest.
Ethical approval
The study design was approved by the appropriate ethics review boards.
About this article
Cite this article
Ogawa, R., Kido, T., Nakamura, M. et al. Magnetic resonance assessment of fetal lung maturity: comparison between signal intensity and volume measurement. Jpn J Radiol 36, 444–449 (2018). https://doi.org/10.1007/s11604-018-0745-0
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11604-018-0745-0