Magnetic resonance assessment of fetal lung maturity: comparison between signal intensity and volume measurement

  • Original Article
  • Published:
Japanese Journal of Radiology Aims and scope Submit manuscript

Abstract

Purpose

We evaluated the associations between gestational age (GA) and lung-to-liver signal intensity ratio (LLSIR) and fetal lung volume (FLV) using magnetic resonance imaging (MRI). Moreover, we evaluated the reproducibility of these measurements.

Materials and methods

LLSIR and FLV were measured using single-shot fast spin-echo MRI in 88 consecutive fetuses. The Spearman test was used to assess the relationships between (1) LLSIR and GA, and (2) FLV and GA in 81 fetuses without lung abnormalities. Intra- and inter-observer reliabilities were assessed using intra-class correlation coefficients (ICCs).

Results

Overall, GA and LLSIR were significantly correlated (r = 0.62, p < 0.001). However, GA and LLSIR were only significantly correlated during the third trimester (before third trimester: r = 0.39, p = 0.08; during third trimester: r = 0.46, p < 0.001). Overall, GA and FLV were significantly correlated (r = 0.72, p < 0.001). FLV was significantly correlated with GA before (r = 0.86, p < 0.001) and during the third trimester (r = 0.47, p < 0.001). All ICCs were above 0.90.

Conclusions

LLSIR and FLV are useful for the assessment of fetal lung maturity and are highly reproducible. Before the third trimester, FLV is more suitable than LLSIR for the evaluation of fetal lung maturity.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Oka Y, Rahman M, Sasakura C, Waseda T, Watanabe Y, Fujii R, et al. Prenatal diagnosis of fetal respiratory function: evaluation of fetal lung maturity using lung-to-liver signal intensity ratio at magnetic resonance imaging. Prenat Diagn. 2014;34:1289–94.

    Article  PubMed  PubMed Central  Google Scholar 

  2. O’Brien WF, Cefalo RC. Clinical applicability of amniotic fluid tests for fetal pulmonic maturity. Am J Obstet Gynecol. 1980;136:135–44.

    Article  PubMed  Google Scholar 

  3. Rubesova E. Why do we need more data on MR volumetric measurements of the fetal lung? Pediatr Radiol. 2016;46:167–71.

    Article  PubMed  Google Scholar 

  4. Jaffe TA, Miller CM, Merkle EM. Practice patterns in imaging of the pregnant patient with abdominal pain: a survey of academic centers. AJR Am J Roentgenol. 2007;189:1128–34.

    Article  PubMed  Google Scholar 

  5. Ray JG, Vermeulen MJ, Bharatha A, Montanera WJ, Park AL. Association between MRI exposure during pregnancy and fetal and childhood outcomes. JAMA. 2016;316:952–61.

    Article  PubMed  Google Scholar 

  6. Moshiri M, Mannelli L, Richardson ML, Bhargava P, Dubinsky TJ. Fetal lung maturity assessment with MRI fetal lung-to-liver signal-intensity ratio. AJR Am J Roentgenol. 2013;201:1386–90.

    Article  PubMed  Google Scholar 

  7. Kasprian G, Balassy C, Brugger PC, Prayer D. MRI of normal and pathological fetal lung development. Eur J Radiol. 2006;57:261–70.

    Article  PubMed  Google Scholar 

  8. Kuwashima S, Nishimura G, Iimura F, Kohno T, Watanabe H, Kohno A, et al. Low-intensity fetal lungs on MRI may suggest the diagnosis of pulmonary hypoplasia. Pediatr Radiol. 2001;31:669–72.

    Article  PubMed  CAS  Google Scholar 

  9. Paek BW, Coakley FV, Lu Y, Filly RA, Lopoo JB, Qayyum A. Congenital diaphragmatic hernia: prenatal evaluation with MR lung volumetry—preliminary experience. Radiology. 2001;220:63–7.

    Article  PubMed  CAS  Google Scholar 

  10. Brewerton LJ, Chari RS, Liang Y, Bhargava R. Fetal lung-to-liver signal intensity ratio at MR imaging: development of a normal scale and possible role in predicting pulmonary hypoplasia in utero. Radiology. 2005;235:1005–10.

    Article  PubMed  Google Scholar 

  11. van der Vorst JR, van Dam RM, van Stiphout RS, van den Broek MA, Hollander IH, Kessels AG, et al. Virtual liver resection and volumetric analysis of the future liver remnant using open source image processing software. World J Surg. 2010;34:2426–33.

    Article  PubMed  PubMed Central  Google Scholar 

  12. Ward VL, Nishino M, Hatabu H, Estroff JA, Barnewolt CE, Feldman HA, et al. Fetal lung volume measurements: determination with MR imaging—effect of various factors. Radiology. 2006;240:187–93.

    Article  PubMed  Google Scholar 

  13. Keller TM, Rake A, Michel SC, Seifert B, Wisser J, Marincek B, et al. MR assessment of fetal lung development using lung volumes and signal intensities. Eur Radiol. 2004;14:984–9.

    Article  PubMed  Google Scholar 

  14. Osada H, Kaku K, Masuda K, Iitsuka Y, Seki K, Sekiya S. Quantitative and qualitative evaluations of fetal lung with MR imaging. Radiology. 2004;231:887–92.

    Article  PubMed  Google Scholar 

  15. Mills M, Winter TC, Kennedy AM, Woodward PJ. Determination of fetal lung maturity using magnetic resonance imaging signal intensity measurements. Ultrasound Q. 2014;30:61–7.

    Article  PubMed  Google Scholar 

  16. Laudy JA, Wladimiroff JW. The fetal lung. 1: developmental aspects. Ultrasound Obstet Gynecol. 2000;16:284–90.

    Article  PubMed  CAS  Google Scholar 

  17. Dubinsky TJ, Moshiri M, Adams Waldorf K, Wilson G, Maki JH, Hippe DS. Increased fetal lung T2 signal is not due to increasing surfactant concentration: an in vitro T2 mapping analysis. Prenat Diagn. 2017;37:211–4.

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  18. Duncan KR, Gowland PA, Moore RJ, Baker PN, Johnson IR. Assessment of fetal lung growth in utero with echo-planar MR imaging. Radiology. 1999;210:197–200.

    Article  PubMed  CAS  Google Scholar 

  19. Deshmukh S, Rubesova E, Barth R. MR assessment of normal fetal lung volumes: a literature review. AJR Am J Roentgenol. 2010;194:W212–7.

    Article  PubMed  Google Scholar 

  20. Rypens F, Metens T, Rocourt N, Sonigo P, Brunelle F, Quere MP. Fetal lung volume: estimation at MR imaging-initial results. Radiology. 2001;219:236–41.

    Article  PubMed  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Ryo Ogawa.

Ethics declarations

Conflict of interest

The authors declare that there is no conflict of interest.

Ethical approval

The study design was approved by the appropriate ethics review boards.

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Ogawa, R., Kido, T., Nakamura, M. et al. Magnetic resonance assessment of fetal lung maturity: comparison between signal intensity and volume measurement. Jpn J Radiol 36, 444–449 (2018). https://doi.org/10.1007/s11604-018-0745-0

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11604-018-0745-0

Keywords

Navigation