Monitoring respiratory rates with a wearable system using a stretchable strain sensor during moderate exercise

  • Original Article
  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

Respiratory rate, a sensitive indicator of respiratory status, is rarely measured during the field walking test. Our objective was to develop and validate a non-invasive, wearable monitoring system using stretchable strain sensors and an accompanying algorithm capable of providing real-time measurements of respiration during exercise. Twenty-four healthy volunteers wore stretchable sensors during a walking test protocol that included standing, sitting, walking, and walking with a stick. Sensors were placed on the ribcage and abdomen. The Bland-Altman method was used to assess the accuracy and precision of breath counts; total respiration time and inspiration time ratio were determined by custom algorithms and compared with measurements obtained with the standard flow sensor. The output signal from the stretchable sensor was highly synchronized with flow signals. The limits of agreement were within 3 breaths/min throughout the test protocol. Differences between sensors for total respiration time and inspiration time ratio were less than 14% and 26%, respectively. The agreement was maintained regardless of respiratory rate or volume. The wearable respiratory monitoring system yielded accurate and precise breath counts and total duration of respiratory cycle during moderate exercise in healthy young individuals, suggesting that it might be useful in clinical practice.

Graphical abstract

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8

Similar content being viewed by others

Abbreviations

ABD:

Abdomen

BC:

Breath count

FLOW:

Flow sensor

LOA:

Limit of agreement

RC:

Ribcage

RMSRD:

Root mean square relative difference

STR:

Stretchable strain sensor

STS:

Sit-to-stand/stand-to-sit

TT:

Total time of respiratory duration

TITT:

Time of inspiration per total time of respiratory duration (inspiration time ratio)

References

  1. Amjadi M, Kyung KU, Park I, Sitti M (2016) Stretchable, skin-mountable, and wearable strain sensors and their potential applications: a review. Adv Funct Mater 26:1678–1698

    Article  CAS  Google Scholar 

  2. (2002) ATS statement: guidelines for the six-minute walk test. Am J Respir Crit Care Med 166:111-117. https://doi.org/10.1164/ajrccm.166.1.at1102

  3. Bland JM, Altman DG (1986) Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1:307–310

    Article  CAS  Google Scholar 

  4. Bland JM, Altman DG (2007) Agreement between methods of measurement with multiple observations per individual. J Biopharm Stat 17:571–582. https://doi.org/10.1080/10543400701329422

    Article  PubMed  Google Scholar 

  5. Bloch KE, Barandun J, Sackner MA (1995) Effect of mouthpiece breathing on cardiorespiratory response to intense exercise. Am J Respir Crit Care Med 151:1087–1092. https://doi.org/10.1164/ajrccm.151.4.7697236

    Article  CAS  PubMed  Google Scholar 

  6. Cabiddu R, Pantoni CB, Mendes RG, Trimer R, Catai AM, Borghi-Silva A (2016) Inductive plethysmography potential as a surrogate for ventilatory measurements during rest and moderate physical exercise. Braz J Phys Ther 20:184–188. https://doi.org/10.1590/bjpt-rbf.2014.0147

    Article  PubMed  PubMed Central  Google Scholar 

  7. Chadha TS, Watson H, Birch S, Jenouri GA, Schneider AW, Cohn MA, Sackner MA (1982) Validation of respiratory inductive plethysmography using different calibration procedures. Am Rev Respir Dis 125:644–649

    CAS  PubMed  Google Scholar 

  8. Chu M, Nguyen T, Pandey V, Zhou Y, Pham HN, Bar-Yoseph R, Radom-Aizik S, Jain R, Cooper DM, Khine M (2019) Respiration rate and volume measurements using wearable strain sensors. npj Digit Med 2:8. https://doi.org/10.1038/s41746-019-0083-3

    Article  PubMed  PubMed Central  Google Scholar 

  9. Ciavaglia CE, Guenette JA, Ora J, Webb KA, Neder JA, O'Donnell DE (2014) Does exercise test modality influence dyspnoea perception in obese patients with COPD? Eur Respir J 43:1621–1630. https://doi.org/10.1183/09031936.00151513

    Article  PubMed  Google Scholar 

  10. Clarenbach CF, Senn O, Brack T, Kohler M, Bloch KE (2005) Monitoring of ventilation during exercise by a portable respiratory inductive plethysmograph. Chest 128:1282–1290. https://doi.org/10.1378/chest.128.3.1282

    Article  PubMed  Google Scholar 

  11. Dumond R, Gastinger S, Rahman HA, Le Faucheur A, Quinton P, Kang H, Prioux J (2017) Estimation of respiratory volume from thoracoabdominal breathing distances: comparison of two models of machine learning. Eur J Appl Physiol 117:1533–1555. https://doi.org/10.1007/s00421-017-3630-0

    Article  PubMed  Google Scholar 

  12. Enright PL (2003) The six-minute walk test. Respir Care 48:783–785

    PubMed  Google Scholar 

  13. Folke M, Cernerud L, Ekstrom M, Hok B (2003) Critical review of non-invasive respiratory monitoring in medical care. Med Biol Eng Comput 41:377–383

    Article  CAS  Google Scholar 

  14. Heyde C, Leutheuser H, Eskofier B, Roecker K, Gollhofer A (2014) Respiratory inductance plethysmography-a rationale for validity during exercise. Med Sci Sports Exerc 46:488–495. https://doi.org/10.1249/MSS.0000000000000130

    Article  PubMed  Google Scholar 

  15. Heyde C, Mahler H, Roecker K, Gollhofer A (2015) A wearable respiratory monitoring device--the between-days variability of calibration. Int J Sports Med 36:29–34. https://doi.org/10.1055/s-0034-1385864

    Article  CAS  PubMed  Google Scholar 

  16. Hoffman S, Jedeikin R, Atlas D (1986) Respiratory monitoring with a new impedance plethysmograph. Anaesthesia 41:1139–1142. https://doi.org/10.1111/j.1365-2044.1986.tb12966.x

    Article  CAS  PubMed  Google Scholar 

  17. Holland AE, Spruit MA, Troosters T, Puhan MA, Pepin V, Saey D, McCormack MC, Carlin BW, Sciurba FC, Pitta F, Wanger J, MacIntyre N, Kaminsky DA, Culver BH, Revill SM, Hernandes NA, Andrianopoulos V, Camillo CA, Mitchell KE, Lee AL, Hill CJ, Singh SJ (2014) An official European Respiratory Society/American Thoracic Society technical standard: field walking tests in chronic respiratory disease. Eur Respir J 44:1428–1446. https://doi.org/10.1183/09031936.00150314

    Article  PubMed  Google Scholar 

  18. Johnstone JA, Ford PA, Hughes G, Watson T, Garrett AT (2012) Bioharness (TM) multivariable monitoring device. Part I: Validity. J Sport Sci Med 11:400–408

    Google Scholar 

  19. Jones B, Jarvis P, Lewis JA, Ebbutt AF (1996) Trials to assess equivalence: the importance of rigorous methods. BMJ 313:36–39

    Article  CAS  Google Scholar 

  20. Kaneko H, Shiranita S, Horie J, Hayashi S (2016) Reduced chest and abdominal wall mobility and their relationship to lung function, respiratory muscle strength, and exercise tolerance in subjects with COPD. Respir Care 61:1472–1480. https://doi.org/10.4187/respcare.04742

    Article  PubMed  Google Scholar 

  21. Lee PJ (2016) Clinical evaluation of a novel respiratory rate monitor. J Clin Monit Comput 30:175–183. https://doi.org/10.1007/s10877-015-9697-4

    Article  PubMed  Google Scholar 

  22. Li M, Li H, Zhong W, Zhao Q, Wang D (2014) Stretchable conductive polypyrrole/polyurethane (PPy/PU) strain sensor with netlike microcracks for human breath detection. ACS Appl Mater Interfaces 6:1313–1319. https://doi.org/10.1021/am4053305

    Article  CAS  PubMed  Google Scholar 

  23. Liu H, Guo S, Liu H, Zhang H, Chen S, Kuramoto-Ahuja T, Sato T, Kaneko J, Onoda K, Maruyama H (2018) The best body spot to detect the vital capacity from the respiratory movement data obtained by the wearable strain sensor. J Phys Ther Sci 30:586–589. https://doi.org/10.1589/jpts.30.586

    Article  PubMed  PubMed Central  Google Scholar 

  24. Liu H, Guo S, Zheng K, Guo X, Kuramoto-Ahuja T, Sato T, Onoda K, Maruyama H (2017) Reliability and validity of measuring respiration movement using a wearable strain sensor in healthy subjects. J Phys Ther Sci 29:1543–1547. https://doi.org/10.1589/jpts.29.1543

    Article  PubMed  PubMed Central  Google Scholar 

  25. Lopez-Campos JL, Tan W, Soriano JB (2016) Global burden of COPD. Respirology 21:14–23. https://doi.org/10.1111/resp.12660

    Article  PubMed  Google Scholar 

  26. Muttitt SC, Finer NN, Tierney AJ, Rossmann J (1988) Neonatal apnea: diagnosis by nurse versus computer. Pediatrics 82:713–720

    CAS  PubMed  Google Scholar 

  27. Nakamoto H, Ootaka H, Tada M, Hirata I, Kobayashi F, Kojima F (2015) Stretchable strain sensor based on areal change of carbon nanotube electrode. IEEE Sensors J 15:2212–2218. https://doi.org/10.1109/Jsen.2014.2377022

    Article  CAS  Google Scholar 

  28. O'Donnell DE, Revill SM, Webb KA (2001) Dynamic hyperinflation and exercise intolerance in chronic obstructive pulmonary disease. Am J Respir Crit Care Med 164:770–777. https://doi.org/10.1164/ajrccm.164.5.2012122

    Article  CAS  PubMed  Google Scholar 

  29. Patino M, Redford DT, Quigley TW, Mahmoud M, Kurth CD, Szmuk P (2013) Accuracy of acoustic respiration rate monitoring in pediatric patients. Paediatr Anaesth 23:1166–1173. https://doi.org/10.1111/pan.12254

    Article  PubMed  Google Scholar 

  30. Pegan JD, Zhang J, Chu M, Nguyen T, Park SJ, Paul A, Kim J, Bachman M, Khine M (2016) Skin-mountable stretch sensor for wearable health monitoring. Nanoscale 8:17295–17303. https://doi.org/10.1039/c6nr04467k

    Article  CAS  PubMed  Google Scholar 

  31. Sackner JD, Nixon AJ, Davis B, Atkins N, Sackner MA (1980) Non-invasive measurement of ventilation during exercise using a respiratory inductive plethysmograph. I. Am Rev Respir Dis 122:867–871

    CAS  PubMed  Google Scholar 

  32. Seddon P (2015) Options for assessing and measuring chest wall motion. Paediatr Respir Rev 16:3–10. https://doi.org/10.1016/j.prrv.2014.10.006

    Article  PubMed  Google Scholar 

  33. Spruit MA, Singh SJ, Garvey C, ZuWallack R, Nici L, Rochester C, Hill K, Holland AE, Lareau SC, Man WD, Pitta F, Sewell L, Raskin J, Bourbeau J, Crouch R, Franssen FM, Casaburi R, Vercoulen JH, Vogiatzis I, Gosselink R, Clini EM, Effing TW, Maltais F, van der Palen J, Troosters T, Janssen DJ, Collins E, Garcia-Aymerich J, Brooks D, Fahy BF, Puhan MA, Hoogendoorn M, Garrod R, Schols AM, Carlin B, Benzo R, Meek P, Morgan M, Rutten-van Molken MP, Ries AL, Make B, Goldstein RS, Dowson CA, Brozek JL, Donner CF, Wouters EF, Rehabilitation AETFoP (2013) An official American Thoracic Society/European Respiratory Society statement: key concepts and advances in pulmonary rehabilitation. Am J Respir Crit Care Med 188:e13–e64. https://doi.org/10.1164/rccm.201309-1634ST

    Article  PubMed  Google Scholar 

  34. Wilhelm FH, Roth WT, Sackner MA (2003) The lifeShirt. An advanced system for ambulatory measurement of respiratory and cardiac function. Behav Modif 27:671–691. https://doi.org/10.1177/0145445503256321

    Article  PubMed  Google Scholar 

  35. Yamada T, Hayamizu Y, Yamamoto Y, Yomogida Y, Izadi-Najafabadi A, Futaba DN, Hata K (2011) A stretchable carbon nanotube strain sensor for human-motion detection. Nat Nanotechnol 6:296–301. https://doi.org/10.1038/nnano.2011.36

    Article  CAS  PubMed  Google Scholar 

Download references

Funding

The study was funded by a grant from Bando Chemical Industries Ltd, and was partly supported by a grant from JSPS KAKENHI Grant Numbers JP17K17502, Grant-in-Aid for Young Scientists (B), and JP18K10744.

Author information

Authors and Affiliations

Authors

Contributions

The literature search was done by AY, YO, YG and YW; data collection by AY, YB, YO, YF, YW, and KO; and all authors contributed to study design. Data analysis was done by AY, manuscript preparation by AY, and manuscript review was done by all the authors.

Corresponding author

Correspondence to Akio Yamamoto.

Ethics declarations

Conflict of interest

AY, HN, TT, AI received research grants and part of the experimental materials used for data collection from Bando Chemical Industries Ltd. YB is an employee of Bando Chemical Industries, Ltd.

Ethical approval

All procedures were in accordance with the ethical standards of the institutional and/or national research committee and with the 1964 Helsinki declaration and its later amendments. The study was approved by the ethical standards of the Committee on Human Experimentation at the Graduate School of Health Sciences, Kobe University.

Informed consent

Individual written informed consent was obtained from all participants included in the study.

Additional information

Publisher’s note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Yamamoto, A., Nakamoto, H., Bessho, Y. et al. Monitoring respiratory rates with a wearable system using a stretchable strain sensor during moderate exercise. Med Biol Eng Comput 57, 2741–2756 (2019). https://doi.org/10.1007/s11517-019-02062-2

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11517-019-02062-2

Keywords

Navigation