The application of an AK-10 thermocontroller developed at the All-Russia Research Institute of Physicotechnical and Radio Measurements in the temperature control system of an acoustic gas thermometer makes it possible to improve the characteristics of this system. We performed temperature measurements with the use of an MI6020T bridge and demonstrate the possibility of stabilization of temperature of the resonator at a level of 15 μK. The total standard relative uncertainty of temperature measurements in the transmission of the values of temperature from the resonator to a resistance thermometer is reduced down to 0.25 ppm.
Similar content being viewed by others
References
G. Machin, “The Kelvin redefined,” Meas. Sci. Technol., 29, Nо. 2, 022001 (2018).
L. Pitre, F. Sparasci, L. Risegari, C. Guianvarc’h , C. Martin C., M. E. Himbert, M. D. Plimmer, A. Allard, B. Marty, P. A. Giuliano Albo, B. Gao, M. R. Moldover, and J. B. Mehl, “New measurement of the Boltzmann constant k by acoustic thermometry of helium-4 gas,” Metrologia, 54, Nо. 6, S856–S873 (2017).
R. M. Gaviosso, “A determination of the molar gas constant R by acoustic thermometry in helium,” Metrologia, 52, Nо. 5, S274–S304 (2015).
S. M. Osadchii, B. G. Potapov, K. D. Pilipenko, E. G. Aslanyan, and A. N. Shchipunov, “Measurement of the Boltzmann constant in a quasispherical acoustic resonator,” Izmer. Tekhn., No. 7, 8–13 (2017).
S. M. Osadchii, B. G. Potapov, and K. D. Pilipenko, “Acoustic gas thermometer for the realization of a new definition of Kelvin degree on the basis of the fundamental Boltzmann constant,” Alman. Metrol., No. 12, 15–42 (2017).
S. M. Osadchii, B. G. Potapov, K. D. Pilipenko, E. G. Aslanyan, and A. N. Shchipunov, “Measurements of the Boltzmann constant on the equipment of acoustic gas thermometer,” Vestn. Metrol., No. 3, 5–9 (2017).
J. Pearce, A. I. Pokhodun, B. Fellmuth, D. R. White, R. L. Rusby, P. P. M. Steur, O. Tamura, and W. Tew, “Platinum resistance thermometry,” Guide to the Realization of the ITS-90, BIPM (2016).
V. M. Malyshev and K. D. Pilipenko, “Transmission of the value of temperature of the triple point of water to the acoustic resonator by the comparison method,” Izmer. Tekhn., No. 12, 33–36 (2016).
GOST Р 8.736–2011, GSI. Repeated Direct Measurements. Methods for Processing the Results of Measurements. Basic Principles, Standartinform, Moscow (2013).
B. Gao, C. Pan, L. Pitre, Y. Chen, H. Zhang, Y. Song, H. Chen, W. Liu, D. Han, and E. Luo, “Chinese SPRIGT realizes high temperature stability in the range of 5–25 K,” Sci. Bull., 63, Nо. 12, 580–594 (2018).
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Osadchii, S.М., Potapov, B.G., Petukhov, A.A. et al. Stabilization of the Temperature of Resonator of an Acoustic Gas Thermometer. Meas Tech 61, 932–936 (2018). https://doi.org/10.1007/s11018-018-1527-x
Received:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s11018-018-1527-x