Skip to main content
Log in

Raising the accuracy in determining the geometrical parameters and calibration of vertical cylindrical vessels on checking

  • Published:
Measurement Techniques Aims and scope

Abstract

Methods are described for making measurements with electronic tacheometers and scanners that allow one to raise the productivity of labor by a substantial factor while increasing the accuracy in determining the geometrical parameters of the vessels. Formulas are given for estimating the geometrical parameters from the coordinates of points on the tank walls, and also estimates of the accuracy obtained by least-squares fitting.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. GOST 8.570-2000, Vertical Cylindrical Steel Tanks: Checking Methods [in Russian].

  2. ISO 7507-4:1995, Petroleum and Liquid Petroleum Products: Calibration of Vertical Cylindrical Tanks. Part 4: Internal Electro-Optical Distance-Ranging Method.

  3. ISO 7507-5:2000, Petroleum and Liquid Petroleum Products: Calibration of Vertical Cylindrical Tanks. Part 5: External Electro-Optical Distance-Ranging Method.

  4. ISO 7507-3:1993, Petroleum and Liquid Petroleum Products: Calibration of Vertical Cylindrical Tanks. Part 3: Optical-Triangulation Method.

  5. MP 081/23.80.02, Vertical Cylindrical Tanks: Checking Methods: The Geometrical Method [in Russian].

  6. GOST 8.346-2000, Horizontal Cylindrical Sealed Tanks: Checking Methods [in Russian].

  7. MVU 017/03-2004, Radial Deviations in Vertical Cylindrical Steel Tanks: Method of Making Measurements [in Russian].

  8. MP 081/23.24.99, Horizontal Cylindrical Tanks: Checking Methods: The Geometrical Method [in Russian].

Download references

Author information

Authors and Affiliations

Authors

Additional information

__________

Translated from Izmeritel’naya Tekhnika, No. 3, pp. 29–33, March, 2007.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Samoilenko, A.N., Zaets, V.V. Raising the accuracy in determining the geometrical parameters and calibration of vertical cylindrical vessels on checking. Meas Tech 50, 266–271 (2007). https://doi.org/10.1007/s11018-007-0059-6

Download citation

  • Received:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s11018-007-0059-6

Key words

Navigation