Advertisement

Journal of Radioanalytical and Nuclear Chemistry

, Volume 291, Issue 2, pp 359–364 | Cite as

Monte Carlo simulation of neutron tomography for palm weevil detection

  • Ali A. Alghamdi
Article

Abstract

The use of neutron for Non Destructive Imaging (NDI) techniques has many advantages over other (NDI) methods. Using well-established X-ray imaging techniques can provide easy and direct results with some limitations where the sensitivity for light elements is very low. On the other hand, neutron is highly sensitive to water content and can provide extra qualitative information. Comparing the results of the two imaging techniques are investigated in this work with the aim of identifying the palm weevil. At larva stage of the weevil’s life it is characterized by highly water content in the trunk of the palm tree which itself composed of spongy watery texture in some types of palm tree. MCNPX 2.5.0 code with neutron radiography tally was used to obtain the 2D projection then reconstructed to 3D tomography image using OSCaR post processing package. The neutron and photon mesh tallies is utilized to study the neutron and photon fluences from monoenergetic thermal neutron beam and neutron spectrum. There are fundamental difficulties in neutron detection which result in misleading information arises from neutron scattering when constructing cone beam CT neutron images, however, neutron radiography provide better methods for the weevil detection from 2D projection.

Keywords

Red palm weevil Neutron tomography Early detection MCNPX 

References

  1. 1.
    Aljhohany L (2010) Degradation of date palm trees and date production in Arab countries: causes and potential rehabilitation. Aust J Basic Appl Sci 4(8):3998–4010Google Scholar
  2. 2.
    Red palm weevil (Internet). http://www.redpalmweevil.com. 2011-03-11
  3. 3.
    Ma AKW, Alghamdi AA, Spyrou NM (2011) X-ray CT in the detection of palm weevils. Modern Trends in Activation Analysis (MTAA-13) Conference, College StationGoogle Scholar
  4. 4.
    Bray DE, McBride D (eds) (1992) Nondestructive testing techniques. Wiley-Interscience Publication, CanadaGoogle Scholar
  5. 5.
    Pelowitz DB (2005) MCNPX TM user’s manual. Los Alamos National Laboratory, Los AlamosGoogle Scholar
  6. 6.
  7. 7.
    Omotoso O, Adedire C (2007) Nutrient composition, mineral content and the solubility of the proteins of palm weevil, Rhynchophorus phoenicis f (Coleoptera: Curculionidae). J Zhejiang Univ Sci B. 8(5):318–322CrossRefGoogle Scholar
  8. 8.
    NIST Physical Reference Data [Internet]. http://www.nist.gov/pml/data/index.cfm 2011-03-11
  9. 9.
    Grogan BR (2010) The development of parameterized scatter removal algorithm for nuclear materials identification system imaging. Doctoral Dissertations, The University of Tennessee, KnoxvilleGoogle Scholar

Copyright information

© Akadémiai Kiadó, Budapest, Hungary 2011

Authors and Affiliations

  1. 1.Department of Radiological Sciences, College of Applied Medical SciencesUniversity of DammamDammamSaudi Arabia

Personalised recommendations