Neutron activation analysis for identification of African mineral dust transport



A Gent stacked filter unit sampler was used to collect air particulate matter (APM) in separate coarse (PM2.5–10) and fine (PM2.5) size fractions, at a sub-urban site in Lisbon, Portugal. The sampling was done during the year 2001 and two daily samples were taken per week. The filters were analyzed for particulate mass by instrumental neutron activation analysis (INAA). The chemical analysis of APM levels and the study of the atmospheric dynamics by back-trajectories showed that most of the PM2.5 and PM2.5–10 peaks events were associated with air masses transport from the Saharan desert. High mineral load in ambient particulate matter levels were registered during the Saharan dust outbreaks. The accuracy of INAA to measure Fe, Sc and Sm was evaluated by NIST filter standards, revealing results with an agreement of ± 10%. This method constituted an important tool to identify these events.


Instrumental Neutron Activation Analysis Total Ozone Mapping Spectrometer Hysplit Model African Dust Saharan Desert 
These keywords were added by machine and not by the authors. This process is experimental and the keywords may be updated as the learning algorithm improves.


Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.


  1. 1.
    J. M. Prospero, T. Carlson, J. Geophys. Res., 77 (1972) 5255.CrossRefGoogle Scholar
  2. 2.
    R. Swap, S. Ulanski, M. Cobbett, M. Garstang, J. Geophys. Res., 101 (1996) 4205.CrossRefGoogle Scholar
  3. 3.
    X. Querol, A. Alastuey, S. Rodriguez, F. Plana, C. R. Ruiz, N. Cots, G. Massagué, O. Pluig, Atmos. Environ., 35 (2001) 6407.CrossRefGoogle Scholar
  4. 4.
    R. Chester, E. J. Sharples, G. S. Sanders, A. C. Saydam, Atmos. Environ., 18 (1984) 929.CrossRefGoogle Scholar
  5. 5.
    G. M. Marcazzan, P. Bonelli, E. D. Bella, A. Fumagalli, R. Ricci, U. Pellegrini, Nucl. Instr. Meth., B75 (1993) 312.Google Scholar
  6. 6.
    J. M. Pacyna, Sources Inventories for Atmospheric Trace Metals, in: Atmospheric Particles, Harrison and Van Grieken (Eds), IUPAC Series on Analytical and Physical Chemistry of Environmental Systems, Vol. 5, John Wiley & Sons, Chichester, 1998.Google Scholar
  7. 7.
    X. Li, H. Maring, D. Savoie, K. Voss, J. M. Prospero, Nature, 380 (1996) 416.CrossRefGoogle Scholar
  8. 8.
    I. Tegen, A. A. Lacis, I. Fung, Nature, 380 (1996) 419.CrossRefGoogle Scholar
  9. 9.
    S. M. Almeida, C. A. Pio, M. C. Freitas, M. A. Reis, M. A. Trancoso, Atmos. Environ., 39 (2005) 3127.CrossRefGoogle Scholar
  10. 10.
    S. M. Almeida, C. A. Pio, M. C. Freitas, M. A. Reis, M. A. Trancoso, Atmos. Environ., 40 (2006) 2058.CrossRefGoogle Scholar
  11. 11.
    S. M. Almeida, M. A. Reis, M. C. Freitas, C. A. Pio, Nucl. Instr. Meth., B207 (2003) 434.Google Scholar
  12. 12.
    S. M. Almeida, M. C. Freitas, M. A. Reis, C. A. Pio, J. Radioanal. Nucl. Chem., 257 (2003) 609.CrossRefGoogle Scholar
  13. 13.
    W. Maenhaut, F. François, J. Cafmeyer, The “Gent” stacked filter unit (SFU) sampler for the collection of atmospheric aerosols in two size fractions: description and instructions for installation and use. Applied Research on Air Pollution Using Nuclear-Related Analytical Techniques, Report on the Research Co-ordination Meeting, 1st, Vienna, Mar. 30–Apr. 2, 1993 (1994), Meeting Date 1993, p. 249.Google Scholar
  14. 14.
    H. J. M. Bowen, D. Gibbons, Radioactivation Analysis. Clarendon, Oxford, 1963.Google Scholar
  15. 15.
    F. De Corte, The k0-Standardization Method: A Move to the Optimization of Neutron Activation Analysis, Agregé Thesis, Gent University, Belgium, 1987.Google Scholar
  16. 16.
    M. C. Freitas, M. M. Farinha, M. G. Ventura, S. M. Almeida, M. A. Reis, A. M. G. Pacheco, J. Radioanal. Nucl. Chem., 263 (2005) 711.CrossRefGoogle Scholar
  17. 17.
    R. R. Draxler, Hybrid Single-Particle Lagrangian Integrated Trajectories, Version 3.2, NOAA-ARL, 1994.Google Scholar

Copyright information

© Springer Science+Business Media, LLC. 2007

Authors and Affiliations

  1. 1.Instituto Tecnológico e NuclearSacavémPortugal
  2. 2.Departamento de Ambiente e OrdenamentoUniversidade de AveiroAveiroPortugal

Personalised recommendations