Advertisement

Journal of Medical Systems

, Volume 32, Issue 4, pp 327–332 | Cite as

A New Method to Guard Inpatient Medication Safety by the Implementation of RFID

  • Pei Ran Sun
  • Bo Han Wang
  • Fan Wu
Original Paper

Abstract

Since life is invaluable, the patient safety is always an important issue. How to reduce the malpractices and advance the patient safety is the primary goal of many countries. The current problem is that the hospitals cannot quickly and precisely identify the name of medicine, the position of patient and staff and the servicing time and dosage taken by patients. The application of Radio Frequency Identification (RFID) is rocketing in popularity as varieties of expanded uses. However, due to the investment consideration, there are few cases that practically implement such a technology in healthcare industries. This paper presents a Wisely Aware RFID Dosage (WARD) system, which based on an integration of barcodes and RFID tags, to demonstrate effective and safe patient care environment, for preventing the risk of medication error. Finally, through an evaluation of users’ satisfaction, a reliability of 0.92 and a criterion-related validity of 0.82 show that this system is able to effectively construct the patient-safety-centric environment.

Keywords

Patient safety Radio Frequency Identification Barcodes Adverse Drug Reaction Medical Errors Malpractice 

Reference

  1. 1.
    Goss, L., and Carrico, R., Get a grip on patient safety: outcomes in the palm of your hand. J. Infusion. Nurs. 25:274–279, 2002.CrossRefGoogle Scholar
  2. 2.
    Koshy, R., Navigating the information technology highway: Computer solutions to reduce errors and enhance patient safety. Transfusion. 45:s4189S–205S, 2005.CrossRefGoogle Scholar
  3. 3.
    Simpson, L., Patient and nurse safety: How information technology makes a difference. Nurs. Admin. Q. 29:197–101, 2005.Google Scholar
  4. 4.
    Unruh, K., and Pratt, W., Patients as actors: the patient's role in detecting, preventing, and recovering from medical errors. Int. J. Med. Inform. 76:236–244, 2007.CrossRefGoogle Scholar
  5. 5.
    Gerald, S., Langeberg, A., Kimberly, C., and Laurie, D., Bar code and radio-frequency technologies can increase safety and efficiency of blood transfusions. ASCP 37:7436–439, 2006.Google Scholar
  6. 6.
    Darin, R., and Karen, M., RFID: Bar coding’s replacement? Nursing. Management. 37:228, 2006.Google Scholar
  7. 7.
    Perrin, R. A., and Simpson, N., RFID and bar codes: Critical importance in enhancing safe patient care. J. Healthcare. Inf. Manag. 18:433–39, 2004.Google Scholar
  8. 8.
    Case, J., Mowry, M., and Welebob, E., The nursing shortage: Can technology help? Nursing Economics. 20:146, 2002.Google Scholar
  9. 9.
    Kohn, LT., Corrigan, JM., Donaldson, MS., To Err Is Human: Building a Safer Health System. Washington, DC: National Academy Pr, Pages: 287, 2000.Google Scholar
  10. 10.
    Shojania, K. G., Duncan, B. W., McDonald, K. M. et al., Safe but sound: Patient safety meets evidence-based medicine. JAMA 288:508–13, 2002.CrossRefGoogle Scholar
  11. 11.
    Huzaifa, N., Jitender, D., Radio frequency identification applications in smart hospitals. CBMS, Twentieth IEEE International Symposium. 337–342, 2007.Google Scholar
  12. 12.
    Hightower, J., and Borriello, G., Location systems for ubiquitous computing. IEEE Computer Magazine. 34:857–66, 2001.Google Scholar
  13. 13.
    Walter, D., New technology for transfusion safety. British J. Hematology. 136:2181–190, 2007.CrossRefGoogle Scholar
  14. 14.
    Cullen, D. J., Sweitzer, B. J., Bates, D. W., Burdick, E., Edmondson, A., and Leape, L. L., Preventable adverse drug events in hospitalized patients: a comparative study of intensive care units and general care units. Crit. Care Med. 25:1289–1297, 1997.CrossRefGoogle Scholar
  15. 15.
    Bernard, F., Brian, M., and Aziz, S., Reducing medication-related adverse events in elderly patients. Cambridge University Press. 16:79–87, 2006.Google Scholar
  16. 16.
    Cooper, J., Adverse drug reaction-related hospitalizations of nursing facility patients. South. Med. J. 92:485–90, 1999.CrossRefGoogle Scholar
  17. 17.
    Edwards, E., and Aronson, K., Adverse drug reactions: Definitions, diagnosis and management. Lancet 356:92371255–1259, 2000.CrossRefGoogle Scholar
  18. 18.
    Food and Drug Administration, FR Doc 04-4249: Bar Code Label Requirements for Human Drug Products and Biological Products; Final Rule. FDA 69:389119–9171, 2004.Google Scholar
  19. 19.
    Bonnabry, P., Information technologies for the prevention of medication errors. CHIMIA 59:6359–361, 2005.CrossRefGoogle Scholar
  20. 20.
    Delone, W. H., and Mclean, E. R., Information systems success: The quest for the dependent variable. Inform. Syst. Res. 3:160–95, 1992.CrossRefGoogle Scholar
  21. 21.
    Delone, W. H., and Mclean, E. R., The DeLone and McLean model of information systems success: A ten year update. J. MIS. 19:49–30, 2003.Google Scholar
  22. 22.
    ID TechEx, from www.idtechex.com, 2007.
  23. 23.
    RFID Journal, from www.rfidjournal.com, 2007.
  24. 24.
    Shou-Wei Jian., Li-Hui Zhang., Shi-Chin Chen., Yong-Nian Xu., Cheng-Bo Hou., and Yong-Fu Chen., R.O.C. Patient No. M316725. R.O.C. Taiwan Patent and Trademark Office, 2007.Google Scholar

Copyright information

© Springer Science+Business Media, LLC 2008

Authors and Affiliations

  1. 1.Department of Management Information SystemNational Chung Cheng UniversityMin-Hsiung Chia-YiRepublic of China
  2. 2.Information Technology OfficeChung Shan Medical University HospitalTaichungRepublic of China

Personalised recommendations