Ion selective PVC membrane electrodes for the determination of trazodone hydrochloride in pharmaceutical formulation

Original article


The electrochemical response characteristics of poly(vinyl)chloride (PVC) based membrane electrodes for determination of trazodone hydrochloride (TZH) is described. The membranes of these electrodes consist of trazodone-phosphomolybdate (TZH-PMA) ion pair in a PVC matrix with di-butyl phosphate (DBP) or dioctyl pthalate (DOP) as a plasticizers. The influences of membranes composition, response time, pH of the test solution, and foreign ions on the electrodes performance were investigated. The electrodes exhibited mean slopes of calibration graphs of 56.25 and 58.55 mV per decade of trazodone concentration at 25.0 °C for the optimum electrode 6.0% with DBP (electrode I) and 10.0% with DOP (electrode II) plasticizers respectively. The electrodes were successfully applied to the determination of trazodone hydrochloride and its pharmaceutical preparation with good precision and accuracy.


Ion-selective electrode Potentiometry Pharmaceutical analysis Trazodone hydrochloride 







Phosphomolybdic acid


Ion-selective electrodes






Trazodone hydrochloride


  1. 1.
    Harikrishna, K., Sudhir Kmar, R., Seetharamappa, J., Manjunatha, D.H.: Sensitive extraction spectrophotometric methods for the determination of trazodone hydrochloride in pure and pharmaceutical formulations. J. Serb. Chem. Soc. 71(7), 829–837 (2006)CrossRefGoogle Scholar
  2. 2.
    Nandini, R.P., Deeptaunshu, A.P.: Development and validation of liquid chromatographic method for trazodone hydrochloride. J. Chem. Pharm. Res. 2(2), 478–488 (2010)Google Scholar
  3. 3.
    Carda-Broch, S., Gil-Agustí, M.T., Rambla-Alegre, M., Monferrer-Pons, L.L., Esteve-Romero, J.S.: Determination of trazodone in urine and pharmaceuticals using micellar liquid chromatography with fluorescence detection. J. Chromatogr. 1156, 254–258 (2007)CrossRefGoogle Scholar
  4. 4.
    Siek, T.J.: Determination of trazodone in serum by instrumental thin-layer chromatography. J. Anal. Toxicol. 11(5), 225–227 (1987)Google Scholar
  5. 5.
    Khalil, S., El-Ries, M.A.: AAS and AES determination of furaltadone, methadone and trazodone in pharmaceutical formulations. J. Pharm. Biomed. Anal. 27, 117–122 (2002)CrossRefGoogle Scholar
  6. 6.
    Kauffmann, J.M., Vire, J.C., Patriarche, G.J., Nunez Vergara, L.J., Squella, J.A.: Voltammetric oxidation of trazodone. Electrochim. Acta 32, 1159–1162 (1987)CrossRefGoogle Scholar
  7. 7.
    El-Gindy, A., El-Zeany, B., Tamer, A., Marwan, M.S.: Spectrophotometric, spectrofluorimetric and LC determination of trazodone hydrochloride. J. Pharm. Biomed. Anal. 26, 211–217 (2007)CrossRefGoogle Scholar
  8. 8.
    Magda, M.A., Hawaa, M.K., El-Henawee, M., Mervat, H.: Determination of trazodone HCl and amitriptyline HCl using cobalt thiocyanate via ternary complex formation. J. Sci. Pharm. 67, 241–252 (1999)Google Scholar
  9. 9.
    Magda, M.A., Abdalla, S., Abdellatef, H.E., Mervat, M.H.: New colorimetric methods for the determination of trazodone HCl, famotidine, and diltiazem HCl in their pharmaceutical dosage forms. Anal. Bioanal. Chem. 376(5), 710–714 (2003)CrossRefGoogle Scholar
  10. 10.
    El Gindy, A.E., Farouk, M., Abd El Aziz, O., Abdullah, E.A.: Stability indicating assay of trazodone hydrochloride using high performance liquid chromatography. J. Appl. Sci. Res. 5(11), 2028–2034 (2009)Google Scholar
  11. 11.
    Sa’ez de Viteri, F.J., Diamond, D.: Determination and application of ion selective electrode model parameters using flow injunction and simplex optimization. Analyst 119, 749–758 (1994)CrossRefGoogle Scholar
  12. 12.
    Gadzekpo, V.P.Y., Christian, G.D.: Determination of selectivity coefficients of ions selective electrodes by a matched potential method. Anal. Chim. Acta 164, 279–282 (1984)CrossRefGoogle Scholar
  13. 13.
    Antropov, L.L.: Theoretical Electrochemistry. Mir, Moscow (1977)Google Scholar
  14. 14.
    Baumann, E.: Trace flouride determination with specific ion-selective electrode. Anal. Chim. Acta 42, 127–132 (1986)CrossRefGoogle Scholar
  15. 15.
    Linder, E., Toth, K., Pungor, E.: Dynamic characteristics of ion-selective electrodes, chemical rubber company. CRC Press, Boca Raton, USA (1988)Google Scholar
  16. 16.
    Abdel-Ghanim, N.T., Shoukry, A.F., El-Nashar, R.M.: Flow injection potentiometric determination of pipazethate hydrochloride. Analyst 126, 79–85 (2001)CrossRefGoogle Scholar
  17. 17.
    Belal, F., El-Brashy, A., El-Enany, N., El-Bahay, N.: Kinetic spectrophotometric determination of trazodone HCl in dosage forms and spiked human plasma. M.J.P.S. 25(1), 123–132 (2009)Google Scholar
  18. 18.
    Miller, J.C., Miller, J.N.: Statistics for Analytical Chemistry, 3rd edn, p. 53. Ellis Horwood, Chichester (1993)Google Scholar

Copyright information

© Springer Science+Business Media B.V. 2010

Authors and Affiliations

  • Reda Ammar
    • 1
  • Nuwair khalaf
    • 1
  • Abdulrhman Al-Warthan
    • 1
  1. 1.Chemistry DepartmentCollege of Science, King Saud UniversityRiyadhSaudi Arabia

Personalised recommendations