Skip to main content
Log in

New PTB Setup for the Absolute Calibration of the Spectral Responsivity of Radiation Thermometers

  • Published:
International Journal of Thermophysics Aims and scope Submit manuscript

Abstract

The paper describes the new experimental setup assembled at the PTB for the absolute spectral responsivity measurement of radiation thermometers. The concept of this setup is to measure the relative spectral responsivity of the radiation thermometer using the conventional monochromator-based spectral comparator facility also used for the calibration of filter radiometers. The absolute spectral responsivity is subsequently measured at one wavelength, supplied by the radiation of a diode laser, using the new setup. The radiation of the diode laser is guided with an optical fiber into an integrating sphere source that is equipped with an aperture of absolutely known area. The spectral radiance of this integrating sphere source is determined via the spectral irradiance measured by a trap detector with an absolutely calibrated spectral responsivity traceable to the primary detector standard of the PTB, the cryogenic radiometer. First results of the spectral responsivity calibration of the radiation thermometer LP3 are presented, and a provisional uncertainty budget of the absolute spectral responsivity is given.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. D.R. Taubert, J. Hartmann, J. Hollandt, J. Fischer, in Temperature, Its Measurement and Control in Science and Industry, vol 7, part 1, ed. by D. Ripple (AIP, New York, 2003), pp. 7–12

  2. Taubert D.R., Friedrich R., Hartmann J., Hollandt J.: Metrologia 40, S35 (2003)

    Article  ADS  Google Scholar 

  3. Werner L., Fischer J., Johannsen U., Hartmann J.: Metrologia 37, 279 (2000)

    Article  ADS  Google Scholar 

  4. Yoon H.W.: Metrologia 43, S22 (2006)

    Article  ADS  Google Scholar 

  5. A. Sperling, O. Larionov, U. Grusemann, S. Winter, in Proceedings of the 9th International Conference on New Developments and Applications in Optical Radiometry (NEWRAD), ed. by J. Groebner (PMODWRC, Davos, Switzerland, 2005), p. 93

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to K. Anhalt.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Anhalt, K., Zelenjuk, A., Taubert, D.R. et al. New PTB Setup for the Absolute Calibration of the Spectral Responsivity of Radiation Thermometers. Int J Thermophys 30, 192–202 (2009). https://doi.org/10.1007/s10765-008-0480-3

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10765-008-0480-3

Keywords

Navigation