Skip to main content
Log in

ITS-90 Scale Realization on the New Radiation Thermometer Calibration Facility at NMi VSL

  • Published:
International Journal of Thermophysics Aims and scope Submit manuscript

Abstract

In the first half of 2005, Nederlands Meetinstituut Van Swinden Laboratorium B.V. (NMi VSL) redesigned their facilities for radiation thermometry in a new laboratory building and an opportunity arose to implement new measurement methods. The new facility is used for ITS-90 realization and dissemination in the temperature range from  − 50 °C to 3,000 °C. A study was performed to compare a silver-point realization with a fixed-point blackbody radiator (FP-BBR) to a sodium heat-pipe blackbody radiator (HP-BBR) traceable via a HTSPRT to a contact thermometry silver point. It was found that the fixed-point realization transfer to the sodium heat pipe results in an uncertainty from 0.2 K to 2.4 K for the ITS-90 over the temperature range from 961.78 °C to 3,000 °C.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. J. Fischer, M. Battuello, M. Sadli, M. Ballico, S.N. Park, P. Saunders, Y. Zundong, B.C. Johnson, E. van der Ham, F. Sakuma, G. Machin, N. Fox, W. Li, S. Ugur, M. Matveyev, in Temperature, Its Measurement and Control in Science and Industry, vol. 7, ed. by D.C. Ripple (AIP, Melville, New York, 2003), pp. 631–638

  2. Preston-Thomas H. (1990) Metrologia 27: 3

    Article  ADS  Google Scholar 

  3. D. Yuning, P. Bloembergen, in Proceedings of TEMPMEKO ’99, 7th International Symposium on Temperature and Thermal Measurements in Industry and Science, ed. by J. F. Dubbeldam, M.J. de Groot (Edauw Johannissen bv, Delft, 1999), pp. 555–560

  4. P. Saunders, in Temperature, Its Measurement and Control in Science and Industry, vol. 7, ed. by D.C. Ripple (AIP, Melville, New York, 2003), pp. 825–830

  5. E.W.M. van der Ham, R. Bosma, P.R. Dekker, in Thermosense XXV, ed. by K.E. Cramer, X.P. Maldague, Proceedings of the SPIE, vol. 5073 (2003), pp. 58–72

  6. E.W.M. van der Ham, Recommendations for the standardisation of the specification, testing and calibration of infrared radiation thermometers. Report EC Project SMT4-CT96–2060 TRIRAT (2002)

  7. Machin G., Ricolfi T., Battuello M., Negro G., Jung H.J., Bloembergen P., Bosma R., Ivarsson J., Weckström T. (1996) Metrologia 33: 197

    Article  ADS  Google Scholar 

  8. P. Bloembergen, Y. Duan, R. Bosma, Z. Yuan, in Proceedings of TEMPMEKO ’96, 6th International Symposium on Temperature and Thermal Measurements in Industry and Science, ed. by P. Marcarino (Levrotto and Bella, Torino, 1997), pp. 261–266

  9. van der Ham E.W.M., Bos H.C.D., Schrama C.A. (2003) Metrologia 40: 177

    Article  ADS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to P. R. Dekker.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Dekker, P.R., van der Ham, E.W.M. ITS-90 Scale Realization on the New Radiation Thermometer Calibration Facility at NMi VSL. Int J Thermophys 29, 1001–1013 (2008). https://doi.org/10.1007/s10765-008-0420-2

Download citation

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10765-008-0420-2

Keywords

Navigation