The major results of a study of the temperature state of the flow-through part of a T-125/150 PGU-450 turbine operating in the steam-free and motor regimes are reported. A scheme for transfer of the turbine into the motor regime is proposed.

Keywords

steam gas unit steam turbine steam-free and motor operation temperature state mathematical model research results transfer scheme domain of applicability 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    E. K. Arakelyan and V. A. Starshinov, Increasing the Efficiency and Maneuverability of Thermal Power Plant Equipment [in Russian], Izd. MÉI, Moscow (1993).Google Scholar
  2. 2.
    A. A. Madoyan, B. L. Levchenko, E. K. Arakelyan, et al., Use of the Motor Mode at Thermal Power Plants [in Russian], Énergiya, Moscow (1980).Google Scholar
  3. 3.
    E. K. Arakelyan and K. V. Sakharov, “Astudy of the temperature state of the HPC stages of a T-125/150 PGU-450 turbine during lowsteam operation,” Novoe Ross. Élektroénerg., No. 1 (2013).Google Scholar
  4. 4.
    A. G. Kostyuk and V. V. Frolov, Turbines for Thermal and Nuclear Power Plants [in Russian], Izd. MÉI, Moscow (2001).Google Scholar

Copyright information

© Springer Science+Business Media New York 2015

Authors and Affiliations

  • É. K. Arakelyan
    • 1
  • I. O. Bezdelgin
    • 1
  • K. A. Andryushin
    • 1
  1. 1.National Research University «Moscow Power Engineering Institute»MoscowRussia

Personalised recommendations