Advertisement

Power Technology and Engineering

, Volume 48, Issue 3, pp 241–248 | Cite as

Instrumental and Visual Inspection of Turbogenerator Stator Cores

  • D. V. Kuznetsov
  • F. A. Polyakov
  • M. I. Shandybin
Article
  • 45 Downloads

The article discusses the most common defects of turbogenerator stator cores, their causes and consequences, and methods to detect and localize them. Cases from integrated diagnostic tests are considered.

Keywords

turbogenerator stator core diagnostics 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Collection of Administrative Documents on the Operation of Grids. Electrical Section. Part 1 [in Russian], Izd. ORGRÉS, Moscow (2002).Google Scholar
  2. 2.
    Collection of Explanatory Documents on the Operation of Grids. Electrical Section. Appendix to Collection of Administrative Documents on the Operation of Grids [in Russian], Izd. ORGRÉS, Moscow (2002).Google Scholar
  3. 3.
    D. V. Kuznetsov, V. V. Maslov, V. A. Pikul’skii, V. I. Polyakov, F. A. Polyakov, A. N. Khudyakov, and M. I. Shandybin, “Defects in turbogenerators and methods for their early diagnostics,” Power Techn. Eng., 38(4), 230 – 235 (2004).Google Scholar
  4. 4.
    Company Standard STO 17330282.27.01–2006. Thermal Power Plants. A Procedure for Assessing the Condition of Main Equipment [in Russian], Approved by order No. 200 of JSC “RAO “EÉS Rossii,” March 28 (2007).Google Scholar
  5. 5.
    V. A. Tsvetkov, Diagnostics of Power Generators [in Russian], ÉNAS, Moscow (1995).Google Scholar
  6. 6.
    G. G. Schastlivyi, G. M. Fedorenko, and V. I. Vygovskii, Turbogenerators and Variable Load Profiles [in Russian], Naukova Dumka, Kiev (1985).Google Scholar
  7. 7.
    V. A. Pikul’skii and A. V. Butov, “Ultrasonic testing of laminations in turbogenerator stators for looseness,” Élektr. Stantsii, No. 3, 40 – 45 (1993).Google Scholar
  8. 8.
    F. A. Polyakov, “Electromagnetic detection of short circuits in laminations of turbogenerators,” Élektr. Stantsii, No. 9, 60 – 63 (2002).Google Scholar
  9. 9.
    RD 34.45-51.300–97 Standard Instructions. Scope and Code for Testing Electrical Equipment [in Russian], ÉNAS, Moscow (2007).Google Scholar
  10. 10.
    A. V. Butov, V. A. Pikul’skii, F. A. Polyakov, and M. I. Shandybin, “Electromagnetic method for detecting short circuits in laminations of turbogenerator stators,” Élektr. Stantsii, No. 11 (1998).Google Scholar
  11. 11.
    A. V. Butov, V. A. Pikul’skii, F. A. Polyakov, and M. I. Shandybin, “Assessing the condition of stator laminations in turbogenerators,” Élektr. Stantsii, No. 10, 44 – 48 (2000).Google Scholar
  12. 12.
    D. V. Kuznetsov, “Studying the electromagnetic forces acting on the keybars in the stator core of a turbogenerator,” Élektrichestvo, No. 10, 47 – 53 (2006).Google Scholar
  13. 13.
    D. V. Kuznetsov, “Defects in the vibration-isolation system of high-power turbogenerators: Detection and Elimination Experience,” in: Proc. 6th Sci.-Tech. Conf. on Problems of Vibration, Vibration Adjustment, Vibration Monitoring, and Diagnostics of Equipment at Power Plants [in Russian], Izd. VTI, Moscow (2011).Google Scholar

Copyright information

© Springer Science+Business Media New York 2014

Authors and Affiliations

  • D. V. Kuznetsov
    • 1
  • F. A. Polyakov
    • 1
  • M. I. Shandybin
    • 1
  1. 1.JSC “R&D Center at Federal Grid Company of Unified Energy System,”MoscowRussia