Skip to main content
Log in

Improved contact lens electrode for corneal ERG recordings in mice

  • Published:
Documenta Ophthalmologica Aims and scope Submit manuscript

Abstract

The electroretinogram (ERG) is routinely used to study retinal physiology in the clinic and in research. Due to their outstanding properties, contact lens electrodes (CLEs) are widely used for ERG recordings. Though the procedures for ERG recordings in mice are similar to those used in humans and larger vertebrates, use of CLEs in the mouse has been limited because of difficulties involved with the manufacturing of small contact lenses. We describe a simple instrument and method for manufacturing contact lenses and CLEs for stable ERG recordings in mice. The instrument operates like a hole-punch and is based on slip joint pliers incorporating a ball bearing on one jaw and forming plate on the other. These CLEs are simple to manufacture, inexpensive and provide stable, long-term recordings of corneal ERGs in mice. With minor modifications, these CLEs could be made for other small animals such as rats or fish.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Similar content being viewed by others

References

  1. Pinto LH, Enroth-Cugell C.Tests of the mouse visual system. Mamm Genome 2000; 11(7): 531–6.

    Google Scholar 

  2. Peachey NS, Ball SL. Electrophysiological analysis of visual function in mutant mice.Doc Ophthalmol 2003; 107(1): 13–36.

    Google Scholar 

  3. Dalke C, Loster J, Fuchs H, Gailus-Durner V, Soewarto D, Favor J, Neuhauser-Klaus A, Pretsch W, Gekeler F, Shinoda K, Zrenner E, Meitinger T, Hrabe de Angelis M, Graw J. Electroretinography as a screening method for mutations causing retinal dysfunction in mice. Invest Ophthalmol Vis Sci 2004; 45(2): 601–9.

    Google Scholar 

  4. Gjotterberg M. Electrodes for electroretinography.A comparison of four different types.Arch Ophthalmol 1986; 104(4): 569–70.

    Google Scholar 

  5. Bayer AU, Mittag T, Cook P, Brodie SE, Podos SM, Maag KP. Comparisons of the amplitude size and the reproducibility of three different electrodes to record the corneal flash electroretinogram in rodents. Doc Ophthal-mol 1999; 98(3): 233–46.

    Google Scholar 

  6. Bayer AU, Cook P, Brodie SE, Maag KP, Mittag T. Evaluation of different recording parameters to establish a standard for.ash electroretinography in rodents. Vision Res 2001; 41(17): 2173–85.

    Google Scholar 

  7. Lachapelle P, Blain L.A new speculum electrode for electroretinography.J Neurosci Methods 1990; 32(3): 245–9.

    Google Scholar 

  8. Mizunoya S, Kuniyoshi K, Arai M, Tahara K, Hirose T. Electroretinogram contact lens electrode with tri-color light-emitting diode. Acta Ophthalmol Scand 2001; 79(5): 497–500.

    Google Scholar 

  9. Tsuruoka M, Yamamoto S, Ogata K, Hayashi M. Built-in LED contact lens electrode for S-cone electroretino-graphic recordings. Documenta Ophthalmologica 2003; (uncorrected proof ): 1–6.

  10. Rosner M, Bobak P, Lam TL. Corneal electrode for recording electroretinograms in rats. Doc Ophthalmol 1993; 83(2): 175–80.

    Google Scholar 

  11. Remtulla S, Hallett PE.A schematic eye for the mouse, and comparisons with the rat. Vision Res 1985; 25(1): 21–31.

    Google Scholar 

  12. Bach M. Preparation and Montage of DTL-Electrodes 1998.http: //www.ukl.uni-freiburg.de/aug/bach/ops/dtl/ index.html.

  13. Dawson WW, Trick GL, Litzkow CA. Improved elec-trode for electroretinography. Invest Ophthalmol Vis Sci 1979; 18(9): 988–91.

    Google Scholar 

  14. Saszik SM, Robson JG, Frishman LJ. The scotopic threshold response of the dark-adapted electroretinogram of the mouse. J Physiol 2002; 543(Pt 3): 899–916.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sagdullaev, B., DeMarco, P. & McCall, M. Improved contact lens electrode for corneal ERG recordings in mice. Doc Ophthalmol 108, 181–184 (2004). https://doi.org/10.1007/s10633-004-5734-1

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10633-004-5734-1

Navigation