Abstract
Earlier measurements in large synchronous generators indicate the existence of complex whirling motion, and also deviations of shape in both the rotor and the stator. These non-symmetric geometries produce an attraction force between the rotor and the stator, called unbalanced magnetic pull (UMP). The target of this paper is to analyse responses due to certain deviations of shape in the rotor and the stator. In particular, the perturbation on the rotor is considered to be of oval character, and the perturbations of the stator are considered triangular. By numerical and analytical methods it is concluded for which generator parameters harmful conditions, such as complicated whirling motion and high amplitudes, will occur. During maintenance of hydro power generators the shapes of the rotor and stator are frequently measured. The results from this paper can be used to evaluate such measurements and to explain the existence of complex whirling motion.
Similar content being viewed by others
References
Talas, P., Toom, P.: Dynamic measurement and analysis of air-gap variations in large hydroelectric generators. IEEE Transactions on Power Apparatus and Systems 9, 102 (1983)
Frosini, L., Pennacchi, P.: Detection and Modelling of Rotor Eccentricity in Electric Machines—an Overview. IMechE Event Publications 2 (2004)
Lundström, N.L.P., Aidanpää, J.-O.: Dynamic consequences of electromagnetic pull due to deviations in generator shape. Journal of Sound and Vibration 1–2, 301 (2007).
Lundström, N.L.P., Aidanpää, J.-O.: Whirling frequencies and amplitudes due to deviations of generator shape. International Journal of Non-Linear Mechanics 43, 9 (2008)
Wang, Y., Sun, G., Huang, L.: Magnetic Field-induced Nonlinear Vibration of an Unbalanced Rotor. In: Proceedings of ASME Design Engineering Division 2, (2003)
Wangsness, R.K.: Electromagnetic Fields, 2nd edition, Hamilton Printing Company, United States (1986)
Sadarangani, C.: Electrical Machines Design and Analysis of Induction and Permanent Magnet Motors. Royal Institute of Technology, Stockholm (2000)
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Lundström, N.L.P., Aidanpää, JO. Dynamics in large generators due to oval rotor and triangular stator shape. Acta Mech Sin 27, 18–27 (2011). https://doi.org/10.1007/s10409-011-0410-7
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10409-011-0410-7