Table 1 Mean of MR parameters T1, T2 and T2* (ms) are calculated and M0 (a.u) measured for both cardiac tissue and fiber

From: 3D magnetization transfer (MT) for the visualization of cardiac free-running Purkinje fibers: an ex vivo proof of concept

  Tissue Fiber
T1 (ms) 458±42 428±21
T2 (ms) 16.0±1.8 18.1±0.4
T2* (ms) 11.3±2.5 11.6±2.1
M0 (a.u.) 31.6±3.9 31.1±3.2