Bone Tissue Ablation with sub-µs Pulses of a Q-switch CO2 Laser: Histological Examination of Thermal Side Effects

  • Regular Article
  • Published:
Lasers in Medical Science Aims and scope Submit manuscript

Abstract

.

The goal of this study is an in vitro evaluation of thermal side-effects by the application of short sub-µs CO2 laser pulses in combination with an air–water spray on different types of bone tissue. A mechanically Q-switched CO2 laser delivered 300 ns pulses at 9.6 µm wavelength, which were focused down to a spot size of 440 µm on the tissue (a corresponding energy density of 9 J/cm2). Bone samples (blocks from pig femur, rib, or cartilage) were moved through the beam repeatedly until 1–5 mm deep cuts were produced. An air driven water spray was applied to prevent the tissue dehydration. Subsequent visual and histological examinations revealed no carbonisation, melting traces or fissuring of the tissue. An extremely narrow, 2–6 µm thick thermally altered layer was observed at the cut border in compacta and cartilage. No accumulation of the thermal damage occurred with increasing cut depth. Laser incisions in trabecular tissue were accompanied with a 100–200 µm thick zone of thermal necrosis in bone marrow. The difference from compacta and cartilage can be explained considering the particular character of the spreading of the ablation products in the trabecular meshwork. Minor thermal side effects make the Q-switched and probably other short pulsed CO2 laser systems interesting for hard tissue surgery.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Paper received 16 November 2001; accepted after revision 23 April 2002.

Correspondence to: M.M. Ivanenko, Centre of Advanced European Studies and Research, Friedensplatz 16, 53111 Bonn, Germany. Fax: +49 (0) 228/96 56-111; E-mail: ivanenko@caesar.de

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ivanenko, M., Fahimi-Weber, S., Mitra, T. et al. Bone Tissue Ablation with sub-µs Pulses of a Q-switch CO2 Laser: Histological Examination of Thermal Side Effects. Lasers Med Sci 17, 258–264 (2002). https://doi.org/10.1007/s101030200038

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s101030200038

Navigation