Clinical study on the efficacy of LED phototherapy for pain control in an orthodontic procedure

  • Original Article
  • Published:
Lasers in Medical Science Aims and scope Submit manuscript

Abstract

Pain is an unpleasant and emotional subjective sensory experience that occurs during orthodontic procedures. Currently, LED phototherapy is an alternative to the use of laser light as analgesic agent due to similarity of response and lower cost. This case-control, quantitative, qualitative, and longitudinal study aimed to investigate the effect of IR LED phototherapy (λ846 ± 20 nm) in pain during the process of tooth separation during orthodontic treatment. After approval by the Institution Ethics Committee, 40 patients (30 female/10 male, 20–30 years old, average age 24.5 ± 2.6 years old) fulfilling the inclusion criteria entered the study and received a set of four visual analog scales (VAS) for scoring pain immediately, 48 h, 72 h, and 7 days after the insertion of the separating elastics. The patients were randomly distributed into two groups (experimental and control). The patients of experimental group received LED phototherapy (180 mW, 22 s, 4 J, 8 J/cm2, 0.36 W/cm2, spot of 0.5 cm2, spot diameter 0.8 cm) at the same times in which VAS was performed, and control patients were not irradiated. It was found that, in both groups, there was an increase in pain 48 h after insertion of the elastic tooth separator, decreasing 72 h after its installation and reached the lowest level of pain after 7 days. Comparison between groups showed that pain level in the LED group was always statistically significantly lower (p < 0.05), except for the time of installation (T1). The use of LED light was effective in significantly reducing the level of pain after insertion of the elastic tooth separators when compared to the control group.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2

Similar content being viewed by others

References

  1. Carroll JD (2014) Tooth movement in orthodontic treatment systematic review omitted significant articles. Photomed Laser Surg 32:310–311

    Article  PubMed  Google Scholar 

  2. Krishnan V (2007) Orthodontic pain: from causes to management- a review. Eur J Orthod 29:170–179

    Article  PubMed  Google Scholar 

  3. Burstone CJ, Choy K (2017) Fundamentos Biomecânicos da Clínica Ortodôntica. Quintessence, São Paulo

    Google Scholar 

  4. Almeida VL, Gois VLA, Andrade RNM, Cesar CPHAR, Albuquerque-Junior RLC et al (2016) Efficiency of low-level laser therapy within induced dental movement: a systematic review and meta-analysis. J Photochem Photobiol B Biol 158:258–266

    Article  CAS  Google Scholar 

  5. Higashi DT, Andrello AC, Tondelli PM, Filho DOT, Ramos SP (2017) Three consecutive days of application of LED therapy is necessary to inhibit experimentally induced root resorption in rats: a microtomographic study. Lasers Med Sci 32(1):181–187

    Article  PubMed  Google Scholar 

  6. Lim HM, Lew KK, Tay DK (1995) A clinical investigation of the low-level laser therapy in reducing orthodontic post adjustment pain. Am J Orthod Dentofac Orthop 108:614–622

    Article  CAS  Google Scholar 

  7. Carroll JD, Milward MR, Cooper PR, Hadis M, Palin WM (2014) Developments in low level light therapy (LLLT) for dentistry. Dent Mater 30:465–475

    Article  PubMed  Google Scholar 

  8. Law SLS, Southard KA, Law AS, Logan HL, Jakobsen J (2000) An evaluation of preoperative ibuprofen for treatment of pain associated with orthodontic separator placement. Am J Orthod Dentofac Orthop 118:629–635

    Article  Google Scholar 

  9. Bernhardt MK, Southard KA, Batterson KD, Logan HL, Baker KA, Jakobsen JR (2001) The effect of preoperative and/or postoperative ibuprofen therapy for orthodontic pain. Am J Orthod Dentofac Orthop 120:20–27

    Article  CAS  Google Scholar 

  10. Polat O, Karaman AL (2005) Pain control during fixed orthodontic appliance therapy. Angle Orthod 75:210–215

    Google Scholar 

  11. Turhani D, Scheriau M, Kapral D, Benesch T, Jonke E, Bantleon HP (2006) Pain relief by single low-level laser irradiation in orthodontic patients undergoing fixed appliance therapy. Am J Orthod Dentofac Orthop 130:371–377

    Article  Google Scholar 

  12. Bird SE, Williams K, Kula K (2007) Preoperative acetaminophen vs ibuprofen for control of pain after orthodontic separator placement. Am J Orthod Dentofac Orthop 132:504–510

    Article  Google Scholar 

  13. Bergius M, Brogerg AG, Hakeberg M, Berggren U (2008) Prediction of prolonged pain experiences during orthodontic treatment. Am J Orthod Dentofac Orthop 133(3):339.e1-8

    Article  Google Scholar 

  14. Ren C, McGrath C, Yang Y (2015) The effectiveness of low-level diode laser therapy on orthodontic pain management: a systematic review and meta-analysis. Lasers Med Sci 30:1881–1893

    Article  PubMed  PubMed Central  Google Scholar 

  15. Pinheiro ALB, Bittencourt MAV, Filho RFAF (2008) Avaliação clínica da ação antiálgica do laser de baixa potência após instalação de separadores ortodônticos. Rev Assoc Paul Cir Dent 62:98–104

    Google Scholar 

  16. Youssef M, Ashkar S, Hamade E, Gutknecht N, Lampert F, Mir M (2008) The effect of low-level laser therapy during orthodontic movement: a preliminary study. Lasers Med Sci 23:27–33

    Article  PubMed  Google Scholar 

  17. Tortamano A, Lenzi DC, Haddad AC, Bottino MC, Dominguez GC, Vigorito JW (2009) Low-level laser for pain caused by placement of the first orthodontic arch wire. A randomized clinical trial. Am J Orthod Dentofacial Ortho 136:662–667

    Article  Google Scholar 

  18. Stein S, Korbmacher-Steiner H, Popovic N, Braun A (2015) Pain reduced by low-level laser therapy during use of orthodontic separators in early mixed dentition. J Orofac Orthop 76:431–439

    Article  PubMed  Google Scholar 

  19. Borzabadi-Farahani A, Cronshaw M (2017) Lasers in orthodontics. In: Coluzzi D, Parker S (eds) Lasers in dentistry—current concepts. Textbooks in Contemporary Dentistry. Springer, Cham

    Google Scholar 

  20. Furquim RD, Pascotto RC, Neto JR, Cardoso JR, Ramos AL (2015) Low-level laser therapy effects on pain perception related to the use of orthodontic elastomeric separators. Dental Press J Orthod 20(3):37–42

    Article  PubMed  PubMed Central  Google Scholar 

  21. Bjordal JM, Johnson MI, Iversen V, Aimbire F, Lopes-Martins RA (2006) Low-level laser therapy in acute pain: a systematic review of possible mechanisms of action and clinical effects in randomized placebo-controlled trials. Photomed Laser Surg 24(2):158–168

    Article  PubMed  CAS  Google Scholar 

  22. Mizutani K, Musya Y, Wakae K, Kobayashi T, Tobe M, Taira K, Harada T (2004) A clinical study on serum prostaglandin E2 with low-level laser therapy. Photomed Laser Surg 22(6):537–539

    Article  PubMed  Google Scholar 

  23. Polat O (2007) Pain and discomfort after orthodontic appointments. Semin Orthod 13(4):292–300

    Article  Google Scholar 

  24. Esper MALR, Nicolau RA, Arisawa EALS (2011) The effect of two phototherapy protocols on pain control in orthodontic procedure—a preliminary clinical study. Lasers Med Sci 26:657–663

    Article  PubMed  Google Scholar 

  25. Sant’Anna EF, Araújo MTS, Nojima LI, Cunha AC, Silveira BL, Marquezan M (2017) High-intensity laser application in orthodontics. Dental Press J Orthod 22(6):99–109

    Article  PubMed  PubMed Central  Google Scholar 

  26. Habib FAL, Gama SKC, Ramalho LMP et al (2010) Laser-induced alveolar bone changes during orthodontic movement: a histological study on rodents. Photomed Laser Surg 28:823–830

    Article  PubMed  CAS  Google Scholar 

  27. AlSayed HMMA, Sultan K, Hamadah O (2016) Low-level laser therapy effectiveness in accelerating orthodontic tooth movement: a randomized controlled clinical trial. Angle Orthod 87(4):499–504

    Article  Google Scholar 

  28. Bondemark L, Fredriksson K, Ilros S (2004) Separation effect and perception of pain and discomfort from two types of orthodontic separators. World J Orthod 5:172–176

    PubMed  Google Scholar 

  29. Gallagher EJ, Liebman M, Bijur PE (2001) Prospective validation of clinically important changes in pain severity measured on a visual analog scale. Ann Emerg Med 38:633–638

    Article  PubMed  CAS  Google Scholar 

  30. Topolski F, Moro A, Correr GM, Schimim SC (2018) Optimal management of orthodontic pain. J Pain Res 11:589–598

    Article  PubMed  PubMed Central  CAS  Google Scholar 

  31. Lobato PC, Garcia VJ, Kasem K, Torrent JMU, Walton VT, Céspedes CM (2014) Tooth movement in orthodontic treatment with low-level laser therapy: a systematic review of human and animal studies. Photomed Laser Surg 32:302–309

    Article  Google Scholar 

  32. Sousa MVS, Pinzan A, Consolaro A, Henriques JFC, Freitas MR (2014) Systematic literature review: influence of low-level laser on orthodontic movement and pain control in humans. Photomed Laser Surg 32:592–599

    Article  PubMed  Google Scholar 

  33. Barbosa KGN, Sampaio TPD, Rebouças PRM, Catão MHCV, Gomes DQC, Pereira JV (2013) Analgesia during orthodontic treatment with low intensity laser: systematic review. Rev Dor 14(2):137–141

    Article  Google Scholar 

  34. Brugnera A Jr (2009) Laser phototherapy in dentistry. Photomed Laser Surg 27:533–534

    Article  Google Scholar 

  35. Enwemeka CS (2009) Intricacies of dose in laser phototherapy for tissue repair and pain relief. Photomed Laser Surg 27:387–393

    Article  PubMed  Google Scholar 

  36. Qamruddin I, Alam MK, Fida M, Khan AG (2016) Effect of a single dose of low-level laser therapy on spontaneous and chewing pain caused by elastomeric separators. Am J Orthod Dentofac Orthoped 149(1):62–66

    Article  Google Scholar 

  37. Seifi M, Shafeei HA, Daneshdoost S, Mir M (2007) Effects of two types of low-level laser wavelengths (850 and 690nm) on the orthodontic tooth movements in rabbits. Lasers Med Sci 22:261–264

    Article  PubMed  Google Scholar 

  38. Fujita S, Yamaguchi M, Utsunomiya T, Yamamoto H, Kasai K (2008) Low-energy laser stimulates tooth movement velocity via expression of RANK and RANKL. Orthod Craniofacial Res 11:143–155

    Article  CAS  Google Scholar 

  39. Almallha MME, Almahdi WH, Hajeer MY (2016) Evaluation of low level laser therapy on pain perception following orthodontic elastomeric separation: a randomized controlled trial. J Clin Diagn Res 10:23–28

    Google Scholar 

  40. Goulart CS, Nouer PR, Mouramartins L, Garbin IU, de Fátima ZLR (2006) Photoradiation and orthodontic movement: experimental study with canines. Photomed Laser Surg 24:192–196

    Article  PubMed  Google Scholar 

  41. Shi Q, Yang S, Jia F, Xu J (2015) Does low-level laser therapy relieves the pain caused by the placement of the orthodontic separators? A meta-analysis. Head Face Med 11:28

    Article  PubMed  PubMed Central  Google Scholar 

  42. Farias RD, Closs LQ, Jr SAQM (2016) Evaluation of the use of low-level laser therapy in pain control in orthodontic patients: a randomized split-mouth clinical trial. Angle Orthod 86(2):193–198

    Article  PubMed  Google Scholar 

  43. Eslamian L, Farahani AB, Azhiri AH, Badiee MR, Fekrazad R (2014) The effect of 810nm low-level laser therapy on pain caused by orthodontic elastomeric separators. Lasers Med Sci 29:559–564

    Article  PubMed  Google Scholar 

  44. Marini I, Bartolucci ML, Bartolotti F, Innoceti G, Gatto MR, Bonetti GA (2013) The effect of diode superpulsed low-level laser therapy on experimental orthodontic pain caused by elastomeric separator: a randomized controlled clinical trial. Lasers Med Sci 30:35–41

    Article  PubMed  Google Scholar 

  45. Nóbrega C, Silva EMK, Macedo CR (2013) Low-level laser therapy for treatment of pain associated with orthodontic elastomeric separator placement: a placebo-controlled randomized double blind clinical-trial. Photomed Laser Surg 31(1):10–17

    Article  PubMed  CAS  Google Scholar 

  46. Erdinç AME, Dinçer B (2004) Perception of pain during orthodontic treatment with fixed appliances. Eur J Orthod 26:79–85

    Article  PubMed  Google Scholar 

  47. Kim WT, Bayome M, Park JB, Park JH, Baek SH, Kook YA (2013) Effect of frequent laser irradiation on orthodontic pain. A single-blind randomized clinical trial. Angle Orthod 83(4):611–616

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to A. L. B. Pinheiro.

Ethics declarations

This case-control, quantitative and qualitative, longitudinal study was approved by the Ethics Committee of the School of Dentistry of the Federal University of Bahia (Proc. 34159014.30000.5024).

Conflict of interest

The authors declare that they have no conflict of interest.

Ethical statement

The authors hereby confirm that this work followed the Brazilian Resolution CNS 196/96 and was approved by the institution’s Ethics Committee (Proc 34159014.3.0000.524).

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Figueira, I.Z., Sousa, A.P.C., Machado, A.W. et al. Clinical study on the efficacy of LED phototherapy for pain control in an orthodontic procedure. Lasers Med Sci 34, 479–485 (2019). https://doi.org/10.1007/s10103-018-2617-3

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s10103-018-2617-3

Keywords

Navigation