Abstract
Introduction of potentiometric ion-selective electrodes (ISEs) opened a new bright area in pharmaceutical analysis acknowledged as being an eco-friendly, simple, and energy-saving technique that is well-suited with microfabrication. In this contribution, potentiometric ISEs were employed as an alternative green analytical tool with the crucial goal of expanding the effective application of the potentiometric sensors in different disciplines of drug-stability studies and quality-control investigations. Four novel cyclopentolate hydrochloride and phenylephrine hydrochloride selective membrane sensors were constructed and evaluated. Sensors’ fabrication was achieved using potassium tetrakis (4-chlorophenyl) borate, a cationic exchanger, in a polyvinyl chloride polymeric matrix plasticized with 2-nitrophenyl octyl ether and using 2-hydroxy propyl-β-cyclodextrin as an ionophore. A comparative potentiometric study was implemented using two designs of ISEs; a conventional liquid inner contact and a glassy carbon solid-contact one. Using solid-contact ISEs, detection limit was substantially decreased and the discriminative ability in the presence of the most interfering substances was enhanced. This permits simultaneous estimation of both drugs, in spite of their similar ionic characteristics, abolishing the need for any pretreatment or separation steps in their challenging combined ophthalmic formulation as well as in rabbit aqueous humor and in the presence of their degradation products.
Similar content being viewed by others
References
Abd El-Rahman MK, Zazaa H, Ibrahim NB, Mustafa AA (2016) Just-dip-it (potentiometric ion-selective electrode); an innovative way of greening analytical chemistry. ACS Sustain Chem Eng 4(6):3122–3132
The British Pharmacopoeia, Her Majesty’s Stationary office (2016) London
Sweetman SC (2011) Martindale: the complete drug reference, 37th edn. Pharmaceutical Press, London
Roy AK, Guillory JK (1995) The kinetics and mechanism of the hydrolysis of cyclopentolate hydrochloride in alkaline solutions. Int J Pharm 120(2):169–178
Marin A, Barbas C (2004) LC/MS for the degradation profiling of cough–cold products under forced conditions. J Pharm Biomed Anal 35(5):1035–1045
Trommer H, Raith K, Neubert RHH (2010) Investigating the degradation of the sympathomimetic drug phenylephrine by electrospray ionization-mass spectrometry. J Pharm Biomed Anal 52(2):203–209
Rezk MR, Fayed AS, Marzouk HM, Abbas SS (2017) Chromatographic determination of cyclopentolate hydrochloride and phenylephrine hydrochloride in the presence of their potential degradation products. J AOAC Int 100(2):434–444
Rizk MS, Abdel-Haleem FM (2010) Plastic membrane electrodes for the determination of flavoxate hydrochloride and cyclopentolate hydrochloride. Electrochim Acta 55(20):5592–5597
Shoukry AFI, El-Sheikh R, Issa YM, Zareh M (1989) Potentiometric sensor for phenylephrine based on phenylephrine-tetraphenylborate lipophilic salt. Mikrochim Acta III 101–108
Giahi M, Mirzaei M, Veghar Lahijani G (2010) Potentiometric PVC membrane sensor for the determination of phenylephrine hydrochloride in some pharmaceutical products. J Iran Chem Soc 7(2):333–338
Soleymanpour A, Abdifar S, Bani R (2011) Development of a new coated graphite phenylephrine potentiometric sensor and its applications to pharmaceutical and biological analysis. Electroanalysis 23(12):2813–2821
Rezk MR, Fayed AS, Marzouk HM, Abbas SS (2017) Green ion selective electrode potentiometric application for the determination of cinchocaine hydrochloride in presence of its degradation products and betamethasone valerate: a comparative study of liquid and solid inner contact ion-selective electrode membranes. J Electrochem Soc 164:H628–H634
Abd El-Rahman MK, Rezk MR, Mahmoud AM, Elghobashy MR (2015) Design of a stable solid-contact ion-selective electrode based on polyaniline nanoparticles as ion-to-electron transducer for application in process analytical technology as a real-time analyzer. Sensors Actuators B Chem 208:14–21
Buck RP, Linder E (1994) Recommendations for nomenclature of ion selective electrodes (IUPAC recommendations 1994). Pure Appl Chem 66(12):2527–2536
Prankerd RJ (2007) Profiles of drug substances, excipients and related methodology: critical compilation of pKa values for pharmaceutical substances. Elsevier Academic Press
Sideris E, Valsami G, Koupparis M, Macheras P (1999) Studies on the interaction of diflunisal ion with cyclodextrins using ion-selective electrode potentiometry. Eur J Pharm Sci 7(4):271–278
Antoniadou-Vyza E, Buckton G, Michaleas SG, Loukas YL, Efentakis M (1997) The formation of an inclusion complex of methocarbamol with hydroxypropyl-β-cyclodextrin: the effect on chemical stability, solubility and dissolution rate. Int J Pharm 158(2):233–239
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Ethical approval
This work was approved by the Institutional Research Ethical Committee at Faculty of Pharmacy, Cairo University.
Electronic supplementary material
ESM 1
(DOCX 164 kb)
Rights and permissions
About this article
Cite this article
Rezk, M.R., Fayed, A.S., Marzouk, H.M. et al. Potentiometric ion-selective electrodes for determination of cyclopentolate hydrochloride and phenylephrine hydrochloride in their challenging ophthalmic formulation. J Solid State Electrochem 22, 3351–3361 (2018). https://doi.org/10.1007/s10008-018-4045-5
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s10008-018-4045-5