Abstract
Objectives
To evaluate and compare the initial changes in pulpal blood flow (PBF) between conventional and self-ligating fixed orthodontic brackets during leveling and alignment stage using 0.016 × 0.022 NiTi as alignment archwire.
Materials and methods
Twenty-two patients (16 females and 6 males) aged 19.00 ± 2.53 years who presented with mild lower arch crowding were selected to participate in the study. A split mouth study design was applied for each patient. The intervention (self-ligating brackets) was randomly allocated to the right or left side of the patient using the permuted random block size of 2 with 1:1 allocation ratio. Two different fixed appliance brackets were used in the lower arch (self-ligating brackets on one side and conventional brackets on the other side of the same patients. Two alignment archwires; 0.016″ NiTi and 0.016 × 0.022″ NiTi were used in this study. PBF was measured for the lower right and left sides using laser Doppler flowmetry at different time intervals (20 min, 24 h, 72 h, 1 week, and 1 month)
Results
PBF started to decrease 20 min after insertion of both archwires using both types of brackets. Maximum decrease was reached after 72 h of archwire insertion. After 1 week of force application, PBF started to increase to restore its original values after 1 month. Differences between the 2 groups were not significant (P > 0.05).
Conclusions
In both treatment groups, PBF reduced within 48 h. PBF started to increase after 1 week until it reached its original values after 1 month. Changes in PBF at the measured time intervals in the two groups were similar.
Clinical relevance
The use of 0.016 × 0.022″ NiTi immediately after 0.016″ NiTi for alignment does not produce any damaging effect on the teeth.
This is a preview of subscription content, access via your institution.




References
- 1.
Krishnan V, Park Y, Davidovitch Z (2009) Biology of orthodontic tooth movement: an overview. In: Krishnan V, Davidovitch Z (eds) Biological Mechanisms of Tooth Movement. Chichester, Wiley-Blackwell, pp 19–43
- 2.
Alhashimi N, Frithiof L, Brudvik P, Bakhiet M (2001) Orthodontic tooth movement and de novo synthesis of proinflammatory cytokines. Am J Orthod Dentofac Orthop 119:307–312
- 3.
Hemingway R, Williams RL, Hunt JA, Rudge SJ (2001) The influence of bracket type on the force delivery of Ni-Ti archwires. Eur J Orthod 23:233–241
- 4.
Cacciafesta V, Sfondrini MF, Ricciardi A, Scribante A, Klersy C, Auricchio F (2003) Evaluation of friction of stainless steel and esthetic self-ligating brackets in various bracket-archwire combination. Am J Orthod Dentofac Orthop 124:395–402
- 5.
Ordasco G, Farronato G, Festa F, Nucera R, Parazzoli E, Grossi GB (2009) In vitro evaluation of the frictional forces between brackets and archwire with three passive self-ligating brackets. Eur J Orthod 31(6):643–646
- 6.
Gandini P, Orsi L, Bertoncini C, Massironi S, Franchi L (2008) In vitro frictional forces generated by three different ligation methods. Angle Orthod 78(5):917–921
- 7.
Husmann P, Bourauel C, Wessinger M, Jäger A (2002) The frictional behavior of coated guiding archwires. J Orofac Orthop 63:199–211
- 8.
Smith DV, Rossouw PE, Watson P (2003) Quantified simulation of canine retraction: evaluation of frictional resistance. Semin Orthod 9:262–280
- 9.
Griffiths HS, Sherriff M, Ireland AJ (2005) Resistance to sliding with 3 types of elastomeric modules. Am J Orthod Dentofac Orthop 127:670–675
- 10.
Henao SP, Kusy RP (2004) Evaluation of the frictional resistance of conventional and self-ligating bracket designs using standardized archwires and dental typodonts. Angle Orthod 74:202–211
- 11.
Reicheneder CA, Baumert U, Gedrange T, Proff P, Faltermeier A, Muessig D (2007) Frictional properties of aesthetic brackets. Eur J Orthod 29:359–365
- 12.
Kim TK, Kim KD, Baek SH (2008) Comparison of frictional forces during the initial leveling stage in various combinations of self-ligating brackets and archwires with a custom-designed typodont system. Am J Orthod Dentofac Orthop 133:187–e15–187–e24
- 13.
Tecco S, Di Lorio D, Cordasco G, Verrocchi I, Festa F (2007) An in vitro investigation of the influence of self-ligating brackets, low friction ligatures, and archwire on frictional resistance. Eur J Orthod 29:390–397
- 14.
Kasuya S, Nagasaka S, Hanyuada A, Ishimura S, Hirashita A (2007) The effect of ligation on the load-deflection characteristics of nickel-titanium orthodontic wire. Eur J Orthod 29:578–582
- 15.
Petersen A, Rosenstein S, Kim KB, Israel H (2009) Force decay of elastomeric ligatures: influence on unloading force compared to self-ligation. Angle Orthod 79:934–938
- 16.
Sano Y, Ikawa M, Sugawara J, Horiuchi H, Mitani H (2002) The effect of continuous intrusive force on human pulpal blood flow. Eur J Orthod 24:159–166
- 17.
Sabuncuoglu FA, Ersahan S (2014) Changes in maxillary incisor dental pulp blood flow during intrusion by mini-implants. Acta Odontol Scand 72:489–496
- 18.
Gazelius B, Lindh-StroMberg U, Pettersson H, Oberg PA (1993) Laser Doppler technique–a future diagnostic tool for tooth pulp vitality. Int Endod J 26:8–9
- 19.
Franchi L, Baccetti T, Camporesi M, Giuntini V (2009) Forces released by nonconventional bracket or ligature systems during alignment of buccally displaced teeth. Am J Orthod Dentofac Orthop 136:e1–e6 316–17
- 20.
Hamersky PA, Weimer AD, Taintor JF (1980) The effect of orthodontic force application on the pulpal tissue respiration rate in human premolar. Am J Orthod 77:368–378
- 21.
Gopikrishna V, Tinagupta K, Kandaswamy D (2007) Comparison of electrical, thermal, and pulse oximetry methods for assessing pulp vitality in recently traumatized teeth. J Endod 33(5):531–535
- 22.
Fratkin RD, Kenny DJ, Johnston DH (1999) Evaluation of a laser Doppler flowmeter to assess blood flow in human primary incisor teeth. Pediatr Dent 21:53–56
- 23.
Jafarzadeh H (2009) Laser Doppler flowmetry in endodontics: a review. Int Endod J 42:476–490
- 24.
Jafarzadeh H, Rosenberg PA (2009) Pulse oximetry: review of a potential aid in endodontic diagnosis. J Endod 35:329–333
- 25.
Baccetti T, Franchi L, Camporesi M, Defraia E, Barbato E (2009) Forces produced by different nonconventional bracket or ligature systems during alignment of apically displaced teeth. Angle Orthod 79:533–539
- 26.
Brodin P, Linge L, Aars H (1996) Instant assessment of pulpal blood flow after orthodontic force application. J Orofac Orthop 57:306–309
- 27.
Soo-Ampon S, Vongsavan N, Soo-Ampon M, Chuckpaiwong S, Matthews B (2013) The sources of laser Doppler blood-flow signals recorded from human teeth. Arch Oral Biol 48:353–360
- 28.
Salles AW, Salles AM, Nogueira GE (2013) Laser doppler blood-flow signals from human teeth during an alignment and leveling movement using a superelastic archwire. ISRN Dent. https://doi.org/10.1155/2013/102816 Published online 2013 Sep 19
- 29.
Pandis N, Polychronopoulou A, Eliades T (2007) Self-ligating vs conventional brackets in the treatment of mandibular crowding: a prospective clinical trial of treatment duration and dental effects. Am J Orthod Dentofac Orthop 132:208–215
- 30.
Iwasaki LR, Beatty MW, Randall CJ (2003) Nickel JC (2003). Clinical ligation forces and intraoral friction during sliding on a stainless steel archwire. Am J Orthod Dentofac Orthop 123:408–415
- 31.
Burrow SJ (2009) Friction and resistance to sliding in orthodontics: a critical review. Am J Orthod Dentofac Orthop 135:442–447
- 32.
Pandis N, Eliades T, Bourauel C (2009) Comparative assessment of forces generated during simulated alignment with self-ligating and conventional brackets. Eur J Orthod 31:590–595
- 33.
Thorstenson GA, Kusy RP (2001) Resistance to sliding of self-ligating brackets versus conventional stainless steel twin brackets with second-order angulation in the dry and wet (saliva) states. Am J Orthod Dentofac Orthop 120:361–370
- 34.
Sander C, Sander FM, Sander FG (2006) The behavior of the periodontal ligament is influencing the use of new treatment tools. J Oral Rehabil 33:706–711
Funding
The study was supported by the deanship of research at Jordan University of Science and Technology, research grant number (236/2016).
Author information
Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical approval
The study was approved by the institutional ethics and research committee at Jordan University of science and technology, and it is registered with clinicaltrials.gov registration number NCT NCT03780764
Informed consent
A written informed consent was obtained from all participants before the treatment.
Additional information
Publisher’s note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Abu Alhaija, E.S., Taha, N.A. A comparative study of initial changes in pulpal blood flow between conventional and self-ligating fixed orthodontic brackets during leveling and alignment stage. Clin Oral Invest 25, 971–981 (2021). https://doi.org/10.1007/s00784-020-03386-2
Received:
Accepted:
Published:
Issue Date:
Keywords
- Pulpal blood flow
- Self-ligating
- Fixed orthodontics
- Leveling and alignment stage