Abstract
A pulse 720 MHz EPR imager with a permanent magnet, arbitrary waveform generator based excitation, and detection system operating in the direct sampling and signal down-conversion modes is presented. This flexible instrument allowed testing various acquisition modes and demonstrating its signal to noise ratio advantage over the previously used 250 MHz instrument.
Similar content being viewed by others
References
N. Devasahayam, R. Murugesan, K. Matsumoto, J.B. Mitchell, J.A. Cook, S. Subramanian, M.C. Krishna, J. Magn. Reson. 168, 110–117 (2004)
M. Tseitlin, R.W. Quine, G.A. Rinard, S.S. Eaton, G.R. Eaton, J. Magn. Reson. 213, 119–125 (2011)
P.E. Spindler, Y. Zhang, B. Endeward, N. Gershernzon, T.E. Skinner, S.J. Glaser, T.F. Prisner, J. Magn. Reson. 218, 49–58 (2012)
A. Doll, S. Pribitzer, R. Tschaggelar, G. Jeschke, J. Magn. Reson. 230, 27–39 (2013)
H. Sato-Akaba, M. Tseytlin, J. Magn. Reson. 304, 42–52 (2019)
R.H. Pursley, G. Salem, T.J. Pohida, N. Devasahayam, S. Subramanian, M.C. Krishna, Rev. Sci. Instrum. 76(3), 1–6 (2005). https://doi.org/10.1063/1.1903163
S. Subramanian, R. Murugesan, N. Devasahayam, J.A. Cook, M. Afeworki, T. Pohida, R.G. Tschudin, J.B. Mitchell, M.C. Krishna, J. Magn. Reson. 137, 379–388 (1999)
G. Schwarz, Munchner Medizinische Wochenschrift 56, 1217–1218 (1909)
R.H. Thomlinson, L.H. Gray, Br. J. Radiol. 9, 539–563 (1955)
R. Turner, Magn. Reson. Imaging 11, 903–920 (1993)
S.V. Sundramoorthy, B. Epel, H.J. Halpern, Appl. Magn. Reson. 48, 805–811 (2017)
B. Epel, M.K. Bowman, C. Mailer, H.J. Halpern, Magnet Reson Med 72, 362–368 (2014)
B. Epel, S.V. Sundramoorthy, C. Mailer, H.J. Halpern, Conc. Magn. Reson. B 33B, 163–176 (2008)
K.J. Liu, P. Gast, M. Moussavi, S.W. Norby, N. Vahidi, T. Walczak, M. Wu, H.M. Swartz, Proc. Natl Acad. Sci. USA 90, 5438–5442 (1993)
G.A. Rinard, R.W. Quine, J.R. Harbridge, R.T. Song, G.R. Eaton, S.S. Eaton, J. Magn. Reson. 140, 218–227 (1999)
B. Epel, H.J. Halpern, Emagres 6, 149–160 (2017)
H.J. Halpern, M.K. Bowman, EPR Imaging at MHz frequencies, in EPR Imaging and in vivo EPR. ed. by G.R. Eaton, S.S. Eaton, eK. Ohno (CRC Press, Boca Raton, FL, 1991)
G.A. Rinard, S.S. Eaton, G.R. Eaton, J.C.P. Poole, H.A. Farach, in Handbook of electron spin resonance. ed. by C. Poole, H. Farach (New York, Springer Verlag, 1999)
G.A. Rinard, R.W. Quine, S.S. Eaton, G.R. Eaton, J Magn Reson 156, 113–121 (2002)
R.T. Weber, J.A.J.M. Disselhorst, L.J. Prevo, J. Schmidt, W.T. Wenckebach, J. Magn. Reson. 81, 129–144 (1989)
R. Nakaoka, D. Komarov, S. Matsumoto, H. Hirata, Appl. Magn. Reson. 49, 853–867 (2018)
G.A. Rinard, R.W. Quine, L.A. Buchanan, S.S. Eaton, G.R. Eaton, B. Epel, S.V. Sundramoorthy, H.J. Halpern, Appl. Magn. Reson. 48, 1227–1247 (2017)
M. Tseytlin, B. Epel, S. Sundramoorthy, D. Tipikin, H.J. Halpern, J. Magn. Reson. 272, 91–99 (2016)
B. Epel, M.K. Bowman, C. Mailer, H.J. Halpern, Magn Reson Med 72, 362–368 (2014)
Acknowledgements
We acknowledge our colleagues from the Center for EPR Imaging In vivo Physiology at the University of Chicago and National Institutes of Health (NIH USA) grants P41EB002034, R01CA098575, and R50 CA211408. BE and HJH are are also members of a start-up company O2M Technologies.
Author information
Authors and Affiliations
Corresponding author
Additional information
Publisher's Note
Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.
Rights and permissions
About this article
Cite this article
Epel, B., Sundramoorthy, S.V. & Halpern, H.J. 720 MHz Pulse EPR Imager with Arbitrary Waveform Generator-Based Bridge and Direct Sampling. Appl Magn Reson 52, 1031–1040 (2021). https://doi.org/10.1007/s00723-021-01315-4
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00723-021-01315-4