Abstract
Since the advent of microfabrication technology and soft lithography, the lab-on-a-chip concept has emerged as a state-of-the-art miniaturized tool for conducting the multiple functions associated with micro total analyses of nucleic acids, in series, in a seamless manner with a miniscule volume of sample. The enhanced surface-to-volume ratio inside a microchannel enables fast reactions owing to increased heat dissipation, allowing rapid amplification. For this reason, PCR has been one of the first applications to be miniaturized in a portable format. However, the nature of the basic working principle for microscale PCR, such as the complicated temperature controls and use of a thermal cycler, has hindered its total integration with other components into a micro total analyses systems (μTAS). This review (with 179 references) surveys the diverse forms of PCR microdevices constructed on the basis of different working principles and evaluates their performances. The first two main sections cover the state-of-the-art in chamber-type PCR microdevices and in continuous-flow PCR microdevices. Methods are then discussed that lead to microdevices with upstream sample purification and downstream detection schemes, with a particular focus on rapid on-site detection of foodborne pathogens. Next, the potential for miniaturizing and automating heaters and pumps is examined. The review concludes with sections on aspects of complete functional integration in conjunction with nanomaterial based sensing, a discussion on future prospects, and with conclusions.
Similar content being viewed by others
References
Saiki RK, Scharf S, Faloona F, Mullis KB, Horn GT, Erlich HA, Arnheim N (1985) Enzymatic amplification of β-globin genomic sequences and restriction site analysis for diagnosis of sickle cell anemia. Science 230:1350–1354
Stjernström M, Roeraade J (1998) Method for fabrication of microfluidic systems in glass. J Micromech Microeng 8:33–38
McDonald JC, Duffy DC, Anderson JR, Chiu DT, Wu H, Schueller OJA, Whitesides GM (2000) Fabrication of microfluidic systems in poly(dimethylsiloxane). Electrophoresis 21:27–40
Weerakoon-Ratnayake KM, O’Neil CE, Uba FI, Soper SA (2017) Thermoplastic nanofluidic devices for biomedical applications. Lab Chip 17:362–381
Tsao CW (2016) Polymer microfluidics: simple, low-cost fabrication process bridging academic lab research to commercialized production. Micromachines 7:225–235
Northrup MA, Ching MT, White RM, Watson RT (1993) DNA amplification in a microfabricated reaction chamber. Tranducer’93-The 7th Int Conf on Solid-State Sens Actuators (Yokohama, Japan) 924–926
Zou ZQ, Chen X, Jin QH, Yang MS, Zhao JL (2005) A novel miniaturized PCR multi-reactor array fabricated using flip-chip bonding techniques. J Micromech Microeng 15:1476–1481
Zou Q, Miao Y, Chen Y, Sridhar U, Chong CS, Chai T, Tie Y, Teh CHL, Lim TM, Heng CK (2002) Micro-assembled multi-chamber thermal cycler for low-cost reaction chip thermal multiplexing. Sens Actuators A 102:114–121
Nagai H, Murakami Y, Morita Y, Yokoyama K, Tamiya E (2001) Development of a microchamber array for picoliter PCR. Anal Chem 73:1043–1047
Taylor TB, Winn-Deen ES, Picozza E, Woudenberg TM, Albin M (1997) Optimization of the performance of the polymerase chain reaction in silicon-based microstructures. Nucleic Acids Res 25:3164–3168
Asiello PJ, Baeumner AJ (2011) Miniaturized isothermal nucleic acid amplification, a review. Lab Chip 11:1420–1430
Tomita N, Mori Y, Kanda H, Notomi T (2008) Loop-mediated isothermal amplification (LAMP) of gene sequences and simple visual detection of products. Nat Protoc 3:877–882
Reyes JCB, Solon JAA, Rivera WL (2014) Development of a loop-mediated isothermal amplification assay for detection of Trichomonas vaginalis. Diagn Microbiol Infect Dis 79:337–341
Nzelu CO, Gomez EA, Cáceres AG, Sakurai T, Martini-Robles L, Uezato H, Mimori T, Katakura K, Hashiguchi Y, Kato H (2014) Development of a loop-mediated isothermal amplification method for rapid mass-screening of sand flies for Leishmania infection. Acta Trop 132:1–6
Giuffrida MC, Spoto G (2017) Integration of isothermal amplification methods in microfluidic devices: recent advances. Biosens Bioelectron 90:174–186
Goto M, Honda E, Ogura A, Nomoto A, Hanaki K (2009) Colorimetric detection of loop-mediated isothermal amplification reaction by using hydroxyl naphthol blue. BioTechniques 46:167–172
Vincent M, Xu Y, Kong H (2004) Helicase-dependent isothermal DNA amplification. EMBO Rep 5:795–800
Cao A, Zhang CY (2013) Real-time detection of transcription factors using target-converted helicase-dependent amplification assay with zero-background signal. Anal Chem 85:2543–2547
Ha ML, Zhang Y, Lee NY (2016) A functionally integrated thermoplastic microdevice for one-step solid-phase-based nucleic acid purification and isothermal amplification for facile detection of foodborne pathogen. Biotechnol Bioeng 113:2614–2623
Compton J (1991) Nucleic acid sequence-based amplification. Nature 350:91–92
Guatelli JC, Whitfield KM, Kwoh DY, Barringer KJ, Richman DD, Gingeras TR (1990) Isothermal, in vitro amplification of nucleic acids by a multienzyme reaction modeled after retroviral replication. Proc Natl Acad Sci U S A 87:1874–1878
Ali MM, Li F, Zhang Z, Zhang K, Kang DK, Ankrum JA, Le XC, Zhao W (2014) Rolling circle amplification: a versatile tool for chemical biology, materials science and medicine. Chem Soc Rev 43:3324–3341
Sato K, Tachihara A, Renberg B, Mawatari K, Sato K, Tanaka Y, Jarvius J, Nilsson M, Kitamori T (2010) Microbead-based rolling circle amplification in a microchip for sensitive DNA detection. Lab Chip 10:1262–1266
Crannell Z, Castellanos-Gonzalez A, Nair G, Mejia R, White AC, Richards-Kortum R (2016) Multiplexed recombinase polymerase amplification assay to detect intestinal protozoa. Anal Chem 88:1610–1616
Piepenburg O, Williams CH, Stemple DL, Armes NA (2006) DNA detection using recombination proteins. PLoS Biol 4:e204
He Y, Zeng K, Zhang S, Gurung AS, Baloda M, Liu G (2012) Visual detection of gene mutations based on isothermal strand-displacement polymerase reaction and lateral flow strip. Biosens Bioelectron 31:310–315
Kim TH, Park J, Kim CJ, Cho YK (2014) Fully integrated lab-on-a-disc for nucleic acid analysis of food-borne pathogens. Anal Chem 86:3841–3848
Roy E, Stewart G, Mounier M, Malic L, Peytavi R, Clime L, Madou M, Bossinot M, Bergeron MG, Veres T (2015) From cellular lysis to microarray detection, an integrated thermoplastic elastomer (TPE) point of care lab on a disc. Lab Chip 15:406–416
Jung JH, Park BH, Oh SJ, Choi G, Seo TS (2015) Integrated centrifugal reverse transcriptase loop-mediated isothermal amplification microdevice for influenza A virus detection. Biosens Bioelectron 68:218–224
Czilwik G, Messinger T, Strohmeier O, Wadle S, von Stetten F, Paust N, Roth G, Zengerle R, Saarinen P, Niittymäki J, McAllister K, Sheils O, O'Leary J, Mark D (2015) Rapid and fully automated bacterial pathogen detection on a centrifugal-microfluidic LabDisk using highly sensitive nested PCR with integrated sample preparation. Lab Chip 15:3749–3759
Stumpf F, Schwemmer F, Hutzenlaub T, Baumann D, Strohmeier O, Dingemanns G, Simons G, Sager C, Plobner L, von Stetten F, Zengerle R, Mark D (2016) LabDisk with complete reagent prestorage for sample-to-answer nucleic acid based detection of respiratory pathogens verified with influenza A H3N2 virus. Lab Chip 16:199–207
Anderson NG (1969) Computer interfaced fast analyzers. Science 166:317–324
Zhang H, Tran HH, Chung BH, Lee NY (2013) Solid-phase based on-chip DNA purification through a valve-free stepwise injection of multiple reagents employing centrifugal force combined with a hydrophobic capillary barrier pressure. Analyst 138:1750–1757
Yamada M, Seki M (2004) Nanoliter-sized liquid dispenser array for multiple biochemical analysis in microfluidic devices. Anal Chem 76:895–899
Lee NY, Yamada M, Seki M (2004) Pressure-driven sample injection with quantitative liquid dispensing for on-chip electrophoresis. Anal Sci 20:483–487
Oh SJ, Park BH, Choi G, Seo JH, Jung JH, Choi JS, Kim DH, Seo TS (2016) Fully automated and colorimetric foodborne pathogen detection on an integrated centrifugal microfluidic device. Lab Chip 16:1917–1926
Yamanaka ES, Tortajada-Genaro LA, Maquieira Á (2017) Low-cost genotyping method based on allele-specific recombinase polymerase amplification and colorimetric microarray detection. Microchim Acta 184:1453–1462
Kopp MU, de Mello AJ, Manz A (1998) Chemical amplification: continuous-flow PCR on a chip. Science 280:1046–1048
Nakayama T, Kurosawa Y, Furui S, Kerman K, Kobayashi M, Rao SR, Yonezawa Y, Nakano K, Hino A, Yamamura S, Takamura Y, Tamiya E (2006) Circumventing air bubbles in microfluidic systems and quantitative continuous-flow PCR applications. Anal Bioanal Chem 386:1327–1333
Shindo Y, Kuribara H, Matsuoka T, Futo S, Sawada C, Shono J, Akiyama H, Goda Y, Toyoda M, Hino A (2002) Validation of real-time PCR analyses for line-specific quantitation of genetically modified maize and soybean using new reference molecules. J AOAC Int 85:1119–1126
Liu HB, Gong HQ, Ramalingam N, Jiang Y, Dai CC, Hui KM (2007) Micro air bubble formation and its control during polymerase chain reaction (PCR) in polydimethylsiloxane (PDMS) microreactors. J Micromech Microeng 17:2055–2064
Wu W, Kang KT, Lee NY (2011) Bubble-free on-chip continuous-flow polymerase chain reaction: concept and application. Analyst 136:2287–2293
Nakano H, Matsuda K, Yohda M, Nagamune T, Endo I, Yamane T (1994) High speed polymerase chain reaction in constant flow. Biosci Biotechnol Biochem 58:349–352
Hatch AC, Ray T, Lintecum K, Youngbull C (2014) Continuous flow real-time PCR device using multi-channel fluorescence excitation and detection. Lab Chip 14:562–568
Eteshola E, Leckband D (2001) Development and characterization of an ELISA assay in PDMS microfluidic channels. Sens Actuators B 72:129–133
Sun Y, Kwok YC, Nguyen NT (2007) A circular ferrofluid driven microchip for rapid polymerase chain reaction. Lab Chip 7:1012–1017
Wang CH, Chen YY, Liao CS, Hsieh TM, Luo CH, Wu JJ, Lee HH, Lee GB (2007) Circulating polymerase chain reaction chips utilizing multiple-membrane activation. J Micromech Microeng 17:367–375
Chen J, Wabuyele M, Chen H, Patterson D, Hupert M, Shadpour H, Nikitopoulos D, Soper SA (2005) Electrokinetically synchronized polymerase chain reaction microchip fabricated in polycarbonate. Anal Chem 77:658–666
Saito M, Takahashi K, Kiriyama Y, Espulgar WV, Aso H, Sekiya T, Tanaka Y, Sawazumi T, Furui S, Tamiya E (2017) Centrifugation-controlled thermal convection and its application to rapid microfluidic polymerase chain reaction devices. Anal Chem 89:12797–12804
Jeong S, Lim J, Kim MY, Yeom JH, Cho H, Lee H, Shin YB, Lee JH (2018) Portable low-power thermal cycler with dual thin-film Pt heaters for a polymeric PCR chip. Biomed Microdevices 20:14
Xiang Q, Xu B, Fu R, Li D (2005) Real time PCR on disposable PDMS chip with a miniaturized thermal cycler. Biomed Microdevices 7:273–279
Wang F, Burns MA (2009) Performance of nanoliter-sized droplet-based microfluidic PCR. Biomed Microdevices 11:1071–1080
Tian H, Hühmer AFR, Landers JP (2000) Evaluation of silica resins for direct and efficient extraction of DNA from complex biological matrices in a miniaturized format. Anal Biochem 283:175–191
Wolfe KA, Breadmore MC, Ferrance JP, Power ME, Conroy JE, Norris PM, Landers JP (2002) Toward a microchip-based solid-phase extraction method for isolation of nucleic acids. Electrophoresis 23:727–733
Wu Q, Bienvenue JM, Hassan BJ, Kwok YC, Giordano BC, Norris PM, Landers JP, Ferrance JP (2006) Microchip-based macroporous silica sol-gel monolith for efficient isolation of DNA from clinical samples. Anal Chem 78:5704–5710
Lee NY, Yamada M, Seki M (2005) Development of a passive micromixer based on repeated fluid twisting and flattening, and its application to DNA purification. Anal Bioanal Chem 383:776–782
Azimi SM, Nixon G, Ahern J, Balachandran W (2011) A magnetic bead-based DNA extraction and purification microfluidic device. Microfluid Nanofluid 11:157–165
Yi L, Huang Y, Wu T, Wu J (2013) A magnetic nanoparticles-based method for DNA extraction from the saliva of stroke patients. Neural Regen Res 8:3036–3046
Ganesh I, Tran BM, Kim Y, Kim J, Cheng H, Lee NY, Park S (2016) An integrated microfluidic PCR system with immunomagnetic nanoparticles for the detection of bacterial pathogens. Biomed Microdevices 18:116
Yoza B, Matsumoto M, Matsunaga T (2002) DNA extraction using modified bacterial magnetic particles in the presence of amino silane compound. J Biotechnol 94:217–224
Duarte GRM, Price CW, Littlewood JL, Haverstick DM, Ferrance JP, Carrilho E, Landers JP (2010) Characterization of dynamic solid phase DNA extraction from blood with magnetically controlled silica beads. Analyst 135:531–537
Bhattacharyya A, Klapperich CM (2006) Thermoplastic microfluidic device for on-chip purification of nucleic acids for disposable diagnostics. Anal Chem 78:788–792
Root BE, Agarwal AK, Kelso DM, Barron AE (2011) Purification of HIV RNA from serum using a polymer capture matrix in a microfluidic device. Anal Chem 83:982–988
Shin Y, Perera AP, Wong CC, Park MK (2014) Solid phase nucleic acid extraction technique in a microfluidic chip using a novel non-chaotropic agent: dimethyl adipimidate. Lab Chip 14:359–368
Nakagawa T, Tanaka T, Niwa D, Osaka T, Takeyama H, Matsunaga T (2005) Fabrication of amino silane-coated microchip for DNA extraction from whole blood. J Biotechnol 116:105–111
Reedy CR, Price CW, Sniegowski J, Ferrance JP, Begley M, Landers JP (2011) Solid phase extraction of DNA from biological samples in a post-based, high surface area poly(methyl methacrylate) (PMMA) microdevice. Lab Chip 11:1603–1611
Cao W, Easley CJ, Ferrance JP, Landers JP (2006) Chitosan as a polymer for pH-induced DNA capture in a totally aqueous system. Anal Chem 78:7222–7228
Zhang Y, Trinh KTL, Yoo IS, Lee NY (2014) One-step glass-like coating of polycarbonate for seamless DNA purification and amplification on an integrated monolithic microdevice. Sens Actuators B 202:1281–1289
Xu Y, Vaidya B, Patel AB, Ford SM, McCarley RL, Soper SA (2003) Solid-phase reversible immobilization in microfluidic chips for the purification of dye-labeled DNA sequencing fragments. Anal Chem 75:2975–2984
Li Y, Wang Z, Ou LM, Yu HZ (2007) DNA detection on plastic: surface activation protocol to convert polycarbonate substrates to biochip platforms. Anal Chem 79:426–433
Tran HH, Trinh KTL, Lee NY (2013) Pressure-driven one-step solid phase-based on-chip sample preparation on a microfabricated plastic device and integration with flow-through polymerase chain reaction (PCR). J Chromatogr B 936:88–94
Chiesl TN, Shi W, Barron AE (2005) Poly(acrylamide-co-alkylacrylamides) for electrophoretic DNA purification in microchannels. Anal Chem 77:772–779
Ro KW, Lim K, Shim BC, Hahn JH (2005) Integrated light collimating system for extended optical-path-length absorbance detection in microchip-based capillary electrophoresis. Anal Chem 77:5160–5166
Salimi-Moosavi H, Jiang Y, Lester L, McKinnon G, Harrison DJ (2000) A multireflection cell for enhanced absorbance detection in microchip-based capillary electrophoresis devices. Electrophoresis 21:1291–1299
Meunier A, Jouannot O, Fulcrand R, Fanget I, Bretou M, Karatekin E, Arbault S, Guille M, Darchen F, Lemaître F, Amatore C (2011) Coupling amperometry and total internal reflection fluorescence microscopy at ITO surfaces for monitoring exocytosis of single vesicles. Angew Chem Int Ed 50:5081–5084
Jin LJ, Giordano BC, Landers JP (2001) Dynamic labeling during capillary or microchip electrophoresis for laser-induced fluorescence detection of protein-SDS complexes without pre- or postcolumn labeling. Anal Chem 73:4994–4999
Giordano BC, Jin L, Couch AJ, Ferrance JP, Landers JP (2004) Microchip laser-induced fluorescence detection of proteins at submicrogram per milliliter levels mediated by dynamic labeling under pseudonative conditions. Anal Chem 76:4705–4714
Caruso G, Fresta CG, Siegel JM, Wijesinghe MB, Lunte SM (2017) Microchip electrophoresis with laser-induced fluorescence detection for the determination of the ratio of nitric oxide to superoxide production in macrophages during inflammation. Anal Bioanal Chem 409:4529–4538
Qin Y, Zhao J, Huang Y, Li S, Zhao S (2016) Ultrasensitive nuclease activity and inhibition assay using microchip electrophoresis with laser induced fluorescence detection. Anal Methods 8:1852–1857
Woolley AT, Hadley D, Landre P, de Mello AJ, Mathies RA, Northrup MA (1996) Functional integration of PCR amplification and capillary electrophoresis in a microfabricated DNA analysis device. Anal Chem 68:4081–4086
Northrup MA, Benett B, Hadley D, Landre P, Lehew S, Richards J, Stratton P (1998) A miniature analytical instrument for nucleic acids based on micromachined silicon reaction chambers. Anal Chem 70:918–922
Hong JW, Fujii T, Seki M, Yamamoto T, Endo I (2001) Integration of gene amplification and capillary gel electrophoresis on a polydimethylsiloxane-glass hybrid microchip. Electrophoresis 22:328–333
Liu CN, Toriello NM, Mathies RA (2006) Multichannel PCR-CE microdevice for genetic analysis. Anal Chem 78:5474–5479
Taylor SC, Laperriere G, Germain H (2017) Droplet digital PCR versus qPCR for gene expression analysis with low abundant targets: from variable nonsense to publication quality data. Sci Rep 7:2409–2416
Hoffmann J, Trotter M, von Stetten F, Zengerle R, Roth G (2012) Solid-phase PCR in a picowell array for immobilizing and arraying 100 000 PCR products to a microscope slide. Lab Chip 12: 3049–3054
Bhat S, McLaughlin JLH, Emslie KR (2011) Effect of sustained elevated temperature prior to amplification on template copy number estimation using digital polymerase chain reaction. Analyst 136:724–732
Chin WH, Sun Y, Høgberg J, Hung TQ, Wolff A, Bang DD (2017) Solid-phase PCR for rapid multiplex detection of salmonella spp. at the subspecies level, with amplification efficiency comparable to conventional PCR. Anal Bioanal Chem 409:2715–2726
Kersting S, Rausch V, Bier FF, von Nickisch-Rosenegk M (2014) Multiplex isothermal solid-phase recombinase polymerase amplification for the specific and fast DNA-based detection of three bacterial pathogens. Microchim Acta 181:1715–1723
Khodakov DA, Ellis AV (2014) Recent developments in nucleic acid identification using solid-phase enzymatic assays. Microchim Acta 181:1633–1646
Mercier JF, Slater GW, Mayer P (2003) Solid phase DNA amplification: a simple Monte Carlo lattice model. Biophys J 85:2075–2086
Shin Y, Perera AP, Kim KW, Park MK (2013) Real-time, label-free isothermal solid-phase amplification/detection (ISAD) device for rapid detection of genetic alteration in cancers. Lab Chip 13:2106–2114
Tran BM, Nam NN, Son SJ, Lee NY (2018) Nanoporous anodic aluminum oxide internalized with gold nanoparticles for on-chip PCR and direct detection by surface-enhanced Raman scattering. Analyst 143:808–812
Kim YT, Lee D, Heo HY, Kim DH, Seo TS (2015) An integrated slidable and valveless microdevice with solid phase extraction, polymerase chain reaction, and immunochromatographic strip parts for multiplex colorimetric pathogen detection. Lab Chip 15:4148–4155
Crews N, Wittwer C, Palais R, Gale B (2008) Product differentiation during continuous-flow thermal gradient PCR. Lab Chip 8:919–924
Trinh KTL, Lee NY (2018) Glass-polytetrafluoroethylene-glass based sandwich microdevice for continuous-flow polymerase chain reaction and its application for fast identification of foodborne pathogens. Talanta 176:544–550
Almassian DR, Cockrell LM, Nelson WM (2013) Portable nucleic acid thermocyclers. Chem Soc Rev 42:8769–8798
Park N, Kim S, Hahn JH (2003) Cylindrical compact thermal-cycling device for continuous-flow polymerase chain reaction. Anal Chem 75:6029–6033
Sun Y, Satyanarayan MVD, Nguyen NT, Kwok YC (2008) Continuous flow polymerase chain reaction using a hybrid PMMA-PC microchip with improved heat tolerance. Sens Actuators B 130:836–841
Zhang Q, Wang W, Zhang H, Wang Y (2002) Temperature analysis of continuous-flow micro-PCR based on FEA. Sens Actuators B 82:75–81
Obeid PJ, Christopoulos TK, Crabtrees HJ, Backhouse CJ (2003) Microfabricated device for DNA and RNA amplification by continuous-flow polymerase chain reaction and reverse transcription-polymerase chain reaction with cycle number selection. Anal Chem 75:288–295
Schaerli Y, Wootton RC, Robinson T, Stein V, Dunsby C, Neil MAA, French PMW, de Mello AJ, Abell C, Hollfelder F (2009) Continuous-flow polymerase chain reaction of single-copy DNA in microfluidic microdroplets. Anal Chem 81:302–306
Sun K, Yamaguchi A, Ishida Y, Matsuo S, Misawa H (2002) A heater-integrated transparent microchannel chip for continuous-flow PCR. Sens Actuators B 84:283–289
Burns MA, Mastrangelo CH, Sammarco TS, Man FP, Webster JR, Johnson BN, Foerster B, Jones D, Fields Y, Kaiser AR, Burke DT (1996) Microfabricated structures for integrated DNA analysis. Proc Natl Acad Sci U S A 93:5556–5561
Friedman NA, Meldrum DR (1998) Capillary tube resistive thermal cycling. Anal Chem 70:2997–3002
Oda RP, Strausbauch MA, Huhmer AFR, Borson N, Jurrens SR, Craighead J, Wettstein PJ, Eckloff B, Kline B, Landers JP (1998) Infrared-mediated thermocycling for ultrafast polymerase chain reaction amplification of DNA. Anal Chem 70:4361–4368
Roper MG, Easley CJ, Legendre LA, Humphrey JAC, Landers JP (2007) Infrared temperature control system for a completely noncontact polymerase chain reaction in microfluidic chip. Anal Chem 79:1294–1300
Legendre LA, Bienvenue JM, Roper MG, Ferrance JP, Landers JP (2006) A simple, valveless microfluidic sample preparation device for extraction and amplification of DNA from nanoliter-volume samples. Anal Chem 78:1444–1451
Ke C, Berney H, Mathewson A, Sheehan MM (2004) Rapid amplification for the detection of Mycobacterium tuberculosis using a non-contact heating method in a silicon microreactor based thermal cycler. Sens Actuators B 102:308–314
Shaw KJ, Docker PT, Yelland JV, Dyer CE, Greenman J, Greenway GM, Haswell SJ (2010) Rapid PCR amplification using a microfluidic device with integrated microwave heating and air impingement cooling. Lab Chip 10:1725–1728
Issadore D, Humphry KJ, Brown KA, Sandberg L, Weitz DA, Westervelt RM (2009) Microwave dielectric heating of drops in microfluidic devices. Lab Chip 9:1701–1706
Lao AIK, Lee TMH, Hsing IM, Ip NY (2000) Precise temperature control of microfluidic chamber for gas and liquid phase reactions. Sens Actuators 84:11–17
Trau D, Lee TMH, Lao AIK, Lenigk R, Hsing IM, Ip NY, Carles MC, Sucher NJ (2002) Genotyping on a complementary metal oxide semiconductor silicon polymerase chain reaction chip with integrated DNA microarray. Anal Chem 74:3168–3173
Baek S, Min J, Park JH (2010) Wireless induction heating in a microfluidic device for cell lysis. Lab Chip 10:909–917
Debjani P, Venkataraman V (2002) A portable battery-operated chip thermocycler based on induction heating. Sens Actuators A 102:151–156
Lopez J, Prezioso V (2001) A better way to optimize: two-step gradient PCR. Eppendorf BioNews Appl Notes 16:3–4
Krishnan M, Ugaz VM, Burns MA (2002) PCR in a Rayleigh-Bénard convection cell. Science 298:793
Chou WP, Chen PH, Miao M, Kuo LS, Yeh SH, Chen PJ (2011) Rapid DNA amplification in a capillary tube by natural convection with a single isothermal heater. BioTechniques 50:52–57
Krishnan M, Agrawal N, Burns MA, Ugaz VM (2004) Reactions and fluidics in miniaturized natural convection systems. Anal Chem 76:6254–6265
Crews N, Wittwer C, Gale B (2008) Continuous-flow thermal gradient PCR. Biomed Microdevices 10:187–195
Thomas S, Orozco RL, Ameel T (2017) Microscale thermal gradient continuous-flow PCR: a guide to operation. Sens Actuators B 247:889–895
Wu W, Lee NY (2011) Three-dimensional on-chip continuous-flow polymerase chain reaction employing a single heater. Anal Bioanal Chem 400:2053–2060
Wu W, Trinh KTL, Lee NY (2012) Flow-through PCR on a 3D qiandu-shaped polydimethylsiloxane (PDMS) microdevice employing a single heater: toward microscale multiplex PCR. Analyst 137:2069–2076
Trinh KTL, Wu W, Lee NY (2014) Bent polydimethylsiloxane–polycarbonate hybrid microdevice for on-chip flow-through polymerase chain reaction employing a single heater. Microchim Acta 181:1697–1705
Trinh KTL, Wu W, Lee NY (2014) Planar poly(dimethylsiloxane) (PDMS)–glass hybrid microdevice for a flow-through polymerase chain reaction (PCR) employing a single heater assisted by an intermediate metal alloy layer for temperature gradient formation. Sens Actuators B 190:177–184
Dimov IK, Basabe-Desmonts L, Garcia-Cordero JL, Ross BM, Ricco AJ, Lee LP (2011) Stand-alone self-powered integrated microfluidic blood analysis system (SIMBAS). Lab Chip 11:845–850
Qin L, Vermesh O, Shi Q, Heath JR (2009) Self-powered microfluidic chips for multiplexed protein assays from whole blood. Lab Chip 9:2016–2020
Wheeler EK, Benett W, Stratton P, Richards J, Chen A, Christian A, Ness KD, Ortega J, Li LG, Weisgraber TH, Goodson K, Milanovich F (2004) Convectively driven polymerase chain reaction thermal cycler. Anal Chem 76:4011–4016
Chung KH, Park SH, Choi YH (2010) A palmtop PCR system with a disposable polymer chip operated by the thermosiphon effect. Lab Chip 10:202–210
Chen Z, Qian S, Abrams WR, Malamud D, Bau HH (2004) Thermosiphon-based PCR reactor: experiment and modeling. Anal Chem 76:3707–3715
Tachibana H, Saito M, Tsuji K, Yamanaka K, Hoa LQ, Tamiya E (2015) Self-propelled continuous-flow PCR in capillary-driven microfluidic device: microfluidic behavior and DNA amplification. Sens Actuators B 206:303–310
Curcio M, Roeraade J (2003) Continuous segmented-flow polymerase chain reaction for high-throughput miniaturized DNA amplification. Anal Chem 75:1–7
Chou CF, Changrani R, Roberts P, Sadler D, Burdon J, Zenhausern F, Lin S, Mulholland A, Swami N, Terbrueggen R (2002) A miniaturized cyclic PCR device – modeling and experiments. Microelectron Eng 61-62:921–925
Wu W, Trinh KTL, Lee NY (2012) Hand-held syringe as a portable plastic pump for on-chip continuous-flow PCR: miniaturization of sample injection device. Analyst 137:983–990
Wu W, Trinh KTL, Lee NY (2015) Flow-through polymerase chain reaction inside a seamless 3D helical microreactor fabricated utilizing a silicone tube and a paraffin mold. Analyst 140:1416–1420
Wu W, Lee NY (2013) Two-layer microdevice for parallel flow-through PCRs employing plastic syringes for semi-automated sample injection and a single heater for amplification: toward process simplification and system. Sensors Actuators B 181:756–765
Wu W, Trinh KTL, Zhang Y, Lee NY (2015) Portable plastic syringe as a self-actuated pump for long-distance uniform delivery of liquid inside a microchannel and its application for flow-through polymerase chain reaction on chip. RSC Adv 5:12071–12077
Trinh KTL, Wu W, Lee NY (2017) Fabrication of a 3D Teflon microdevice for energy free homogeneous liquid flow inside a long microchannel and its application to continuous-flow PCR. RSC Adv 7:10624–10630
Trinh KTL, Lee NY (2017) A portable microreactor with minimal accessories for polymerase chain reaction: application to the determination of foodborne pathogens. Microchim Acta 184:4225–4233
Petralia S, Verardo R, Klaric E, Cavallaro S, Alessi E, Schneider C (2013) In-check system: a highly integrated silicon lab-on-chip for sample preparation, PCR amplification and microarray detection of nucleic acids directly from biological samples. Sens Actuators B 187:99–105
Liu RH, Yang J, Lenigk R, Bonanno J, Grodzinski P (2004) Self-contained, fully integrated biochip for sample preparation, polymerase chain reaction amplification, and DNA microarray detection. Anal Chem 76:1824–1831
Hwang KY, Jeong SY, Kim YR, Namkoong K, Lim HK, Chung WS, Kim JH, Huh N (2011) Rapid detection of bacterial cell from whole blood: integration of DNA sample preparation into single micro-PCR chip. Sens Actuators B 154:46–51
Easley CJ, Karlinsey JM, Bienvenue JM, Legendre LA, Roper MG, Feldmant SH, Hughes MA, Hewlett EL, Merkel TJ, Ferrance JP, Landers JP (2006) A fully integrated microfluidic genetic analysis system with sample-in-answer-out capability. Proc Natl Acad Sci U S A 103:19272–19277
Choi JR, Hu J, Tang R, Gong Y, Feng S, Ren H, Wen T, Li XJ, Wan Abas WAB, Pingguan-Murphy B, Xu F (2016) An integrated paper-based sample-to-answer biosensor for nucleic acid testing at the point of care. Lab Chip 16:611–621
Meyer R (1999) Development and application of DNA analytical methods for the detection of GMOs in food. Food Control 10:391–399
Tang R, Yang H, Gong Y, You ML, Liu Z, Choi JR, Wen T, Qu Z, Mei Q, Xu F (2017) A fully disposable and integrated paper-based device for nucleic acid extraction, amplification and detection. Lab Chip 17:1270–1279
He Y, Zeng K, Gurung AS, Baloda M, Xu H, Xhang X, Liu G (2010) Visual detection of single-nucleotide polymorphism with hairpin oligonucleotide-functionalized gold nanoparticles. Anal Chem 82:7169–7177
Aveyard J, Mehrabi M, Cossins A, Braven H, Wilson R (2007) One step visual detection of PCR products with gold nanoparticles and a nucleic acid lateral flow (NALF) device. Chem Commun 41:4251–4253
Nagatani N, Yamanaka K, Ushijima H, Koketsu R, Sasaki T, Ikuta K, Saito M, Miyahara T, Tamiya E (2012) Detection of influenza virus using a lateral flow immunoassay for amplified DNA by a microfluidic RT-PCR chip. Analyst 137:3422–3426
Chamorro-Garcia A, de la Escosura-Muñiz A, Espinosa-Castañeda M, Rodriguez-Hernandez CJ, de Torres C, Merkoçi A (2016) Detection of parathyroid hormone-like hormone in cancer cell cultures by gold nanoparticle-based lateral flow immunoassays. Nanomedicine 12:53–61
Du G, Zhang D, Xia B, Xu L, Wu S, Zhan S, Ni X, Zhou X, Wang L (2016) A label-free colorimetric progesterone aptasensor based on the aggregation of gold nanoparticles. Microchim Acta 183:2251–2258
Lafleur JP, Senkbeil S, Jensen TG, Kutter JP (2012) Gold nanoparticle-based optical microfluidic sensors for analysis of environmental pollutants. Lab Chip 12:4651–4656
Wang L, Ma W, Xu L, Chen W, Zhu Y, Xu C, Kotov NA (2010) Nanoparticle-based environmental sensors. Mater Sci Eng R Rep 70:265–274
Rowland CE, Brown CW III, Delehanty JB, Medintz IL (2016) Nanomaterial-based sensors for the detection of biological threat agents. Mater Today 19:464–477
Upadhyayula VK (2012) Functionalized gold nanoparticle supported sensory mechanisms applied in detection of chemical and biological threat agents: a review. Anal Chim Acta 715:1–18
Stephen Inbaraj B, Chen BH (2016) Nanomaterial-based sensors for detection of foodborne bacterial pathogens and toxins as well as pork adulteration in meat products. J Food Drug Anal 24:15–28
Du D, Wang L, Shao Y, Wang J, Engelhard MH, Lin Y (2011) Functionalized graphene oxide as a nanocarrier in a multienzyme labeling amplification strategy for ultrasensitive electrochemical immunoassay of phosphorylated p53. Anal Chem 83:746–752
Li W, Wu P, Zhang H, Cai C (2012) Signal amplification of graphene oxide combining with restriction endonuclease for site-specific determination of DNA methylation and assay of methyltransferase activity. Anal Chem 84:7583–7590
Du D, Yang Y, Lin Y (2012) Graphene-based materials for biosensing and bioimaging. MRS Bull 37:1290–1296
Tang D, Yuan R, Chai Y (2008) Ultrasensitive electrochemical immunosensor for clinical immunoassay using thionine-doped magnetic gold nanospheres as labels and horseradish peroxidase as enhancer. Anal Chem 80:1582–1588
Zhao YT, Zhang WY, Lin Y, Du D (2013) The vital function of Fe3O4@au nanocomposites for hydrolase biosensor design and its application in detection of methyl parathion. Nanoscale 5:1121–1126
Wu Y, Chen C, Liu S (2009) Enzyme-functionalized silica nanoparticles as sensitive labels in biosensing. Anal Chem 81:1600–1607
Yuan L, Hua X, Wu Y, Pan X, Liu S (2011) Polymer-functionalized silica nanosphere labels for ultrasensitive detection of tumor necrosis factor-alpha. Anal Chem 83:6800–6809
Du D, Chen W, Zhang W, Liu D, Li H, Lin Y (2010) Covalent coupling of organophosphorus hydrolase loaded quantum dots to carbon nanotube/Au nanocomposite for enhanced detection of methyl parathion. Biosens Bioelectron 25:1370–1375
Wang J, Liu G, Wu H, Lin Y (2008) Quantum-dot-based electrochemical immunoassay for high-throughput screening of the prostate-specific antigen. Small 4:82–86
Du D, Chen A, Xie Y, Zhang A, Lin Y (2011) Nanoparticle-based immunosensor with apoferritin templated metallic phosphate label for quantification of phosphorylated acetylcholinesterase. Biosens Bioelectron 26:3857–3863
Ahmed S, Bui MP, Abbas A (2016) Paper-based chemical and biological sensors: engineering aspects. Biosens Bioelectron 77:249–263
Klasner SA, Price AK, Hoeman KW, Wilson RS, Bell KJ, Culbertson CT (2010) Paper-based microfluidic devices for analysis of clinically relevant analytes present in urine and saliva. Anal Bioanal Chem 397:1821–1829
Wang W, Wu WY, Wang W, Zhu JJ (2010) Tree-shaped paper strip for semiquantitative colorimetric detection of protein with self-calibration. J Chromatogr A 1217:3896–3899
Abbas A, Fei M, Tian L, Singamaneni S (2013) Trapping proteins within gold nanoparticles assemblies: dynamically tunable hot-spots for nanobiosensing. Plasmonics 8:537–544
Abbas A, Kattumenu R, Tian L, Singamaneni S (2013) Molecular linker-mediated self-assembly of gold nanoparticles: understanding and controlling the dyanmics. Langmuir 29:56–64
Lee CH, Hankus ME, Tian L, Pellegrino PM, Singamaneni S (2011) Highly sensitive surface enhanced Raman scattering substrates based on filter paper loaded with plasmonic nanostructures. Anal Chem 83:8953–8958
Tian L, Morrissey JJ, Kattumenu R, Gandra N, Kharasch ED, Singamaneni S (2012) Bioplasmonic paper as a platform for detection of kidney cancer biomarkers. Anal Chem 84:9928–9934
Yu WW, White IM (2010) Inkjet printed surface enhanced Raman spectroscopy array on cellulose paper. Anal Chem 82:9626–9630
Wu Y, Xue P, Kang Y, Hui KM (2013) Paper-based microfluidic electrochemical immunodevice integrated with nanobioprobes onto graphene film for ultrasensitive multiplexed detection of cancer biomarkers. Anal Chem 85:8661–8668
Choi JR, Hu J, Gong Y, Feng S, Wan Abas WAB, Pingguan-Murphy B, Xu F (2016) An integrated lateral flow assay for effective DNA amplification and detection at the point of care. Analyst 141:2930–2939
Jauset-Rubio M, Svobodová M, Mairal T, McNeil C, Keegan N, Saeed A, Abbas MN, El-Shahawi MS, Bashammakh AS, Alyoubi AO, O’Sullivan CK (2016) Ultrasensitive, rapid and inexpensive detection of DNA using paper based lateral flow assay. Sci Rep 6:37732
Kaur J, Singh KV, Boro R, Thampi KR, Raje M, Varshney GC, Suri CR (2007) Immunochromatographic dipstick assay format using gold nanoparticles labeled protein−hapten conjugate for the detection of atrazine. Environ Sci Technol 41:5028–5036
Crannell ZA, Rohrman B, Richards-Kortum R (2014) Equipment-free incubation of recombinase polymerase amplification reactions using body heat. PLoS One 9:e112146
Songjaroen T, Dungchai W, Chailapakul O, Henry CS, Laiwattanapaisal W (2012) Blood separation on microfluidic paper-based analytical devices. Lab Chip 12:3392–3398
Acknowledgements
This work was supported by the National Research Foundation of Korea (NRF) grant funded by the Korea government (MSIP) (No. NRF-2017R1A2B4008179).
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
The author(s) declare that they have no competing interests.
Rights and permissions
About this article
Cite this article
Lee, N. A review on microscale polymerase chain reaction based methods in molecular diagnosis, and future prospects for the fabrication of fully integrated portable biomedical devices. Microchim Acta 185, 285 (2018). https://doi.org/10.1007/s00604-018-2791-9
Received:
Accepted:
Published:
DOI: https://doi.org/10.1007/s00604-018-2791-9