Background

Hip screw cutout is among the most common causes of intertrochanteric fracture fixation failure using dynamic hip screws (DHS). This study aimed to evaluate the effect of using an additional anti-rotation screw on hip screw migration or cutout in intertrochanteric fracture fixation.

Materials and methods

We screened 488 patients with unilateral fragile intertrochanteric fractures treated with DHS between January 2001 and March 2016. The inclusion criteria were as follows: (1) age ≥ 50 years; (2) low-energy injury; (3) follow-up of at least 6 months; and (4) short barrel plate used in the operation. The exclusion criteria were as follows: (1) combination with other fracture; or (2) pathological fracture. Subsequently, 166 patients were enrolled; of them, 128 underwent surgery using DHS with an additional screw (Group 1) and 38 patients underwent surgery without an additional screw (Group 2). We compared the postoperative results and clinical outcomes while focusing on screw migration and cutout. Furthermore, we investigated the risk factors for lag screw migration.

Results

Bone union was achieved in 160 patients (96.4%) without secondary intervention. Two patients (1.6%) in Group 1 and 1 (2.6%) in Group 2 developed screw cutout, while 18 (14.1%) in Group 1 and 12 (31.6%) in Group 2 developed screw migration. Thus, Group 2 demonstrated a higher screw migration rate. Multiple logistic regression analysis revealed that the additional anti-rotation screw was the most important factor in preventing screw migration (P = 0.019).

Conclusion

The additional anti-rotation screw reduced the lag screw migration rate following DHS surgery for intertrochanteric fractures.

Level of evidence

Level IV, retrospective series.

Keywords

Intertrochanteric fracture Anti-rotation screw Dynamic hip screw Cutout Mechanical failure 

Notes

Compliance with ethical standards

Conflict of interest

The author(s) declare that they have no competing interests

References

  1. 1.
    Kaplan K, Miyamoto R, Levine BR, Egol KA, Zuckerman JD (2008) Surgical management of hip fractures: an evidence-based review of the literature. II: intertrochanteric fractures. J Am Acad Orthop Surg 16(11):665–673CrossRefGoogle Scholar
  2. 2.
    Haidukewych GJ (2009) Intertrochanteric fractures: ten tips to improve results. J Bone Jt Surg Am 91(3):712–719Google Scholar
  3. 3.
    Parker MJ (1992) Cutting-out of the dynamic hip screw related to its position. J Bone Joint Surg Br 74(4):625CrossRefGoogle Scholar
  4. 4.
    Hsueh K-K, Fang C-K, Chen C-M, Su Y-P, Wu H-F, Chiu F-Y (2010) Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients. Int Orthop 34(8):1273–1276CrossRefGoogle Scholar
  5. 5.
    Davis TR, Sher JL, Horsman A, Simpson M, Porter BB, Checketts RG (1990) Intertrochanteric femoral fractures. Mechanical failure after internal fixation. J Bone Joint Surg Br 72(1):26–31CrossRefGoogle Scholar
  6. 6.
    Geller JA, Saifi C, Morrison TA, Macaulay W (2010) Tip-apex distance of intramedullary devices as a predictor of cutout failure in the treatment of peritrochanteric elderly hip fractures. Int Orthop 34(5):719–722CrossRefGoogle Scholar
  7. 7.
    Ehmke LW, Fitzpatrick DC, Krieg JC, Madey SM, Bottlang M (2005) Lag screws for hip fracture fixation: evaluation of migration resistance under simulated walking. J Orthop Res 23(6):1329–1335CrossRefGoogle Scholar
  8. 8.
    Pervez H, Parker MJ, Vowler S (2004) Prediction of fixation failure after sliding hip screw fixation. Injury 35(10):994–998CrossRefGoogle Scholar
  9. 9.
    Freitas A, Torres GM, de Souza ACAME, Maciel RA, Souto de DRM, Ferreira de GNB (2014) Analysis on the mechanical resistance of fixation of femoral neck fractures in synthetic bone, using the dynamic hip system and an anti-rotation screw. Rev Bras Ortop 49(6):586–592CrossRefGoogle Scholar
  10. 10.
    Chen Z, Wang G, Lin J, Yang T, Fang Y, Liu L, Zhang H (2011) Efficacy comparison between dynamic hip screw combined with anti-rotation screw and cannulated screw in treating femoral neck fractures. Zhongguo Xiufu Chongjian Waike Zazhi Chin J Reparative Reconstr Surg 25(1):26–29Google Scholar
  11. 11.
    Audigé L, Cagienard F, Sprecher CM, Suhm N, Müller MA (2014) Radiographic quantification of dynamic hip screw migration. Int Orthop 38(4):839–845CrossRefGoogle Scholar
  12. 12.
    Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM (1995) The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am 77(7):1058–1064CrossRefGoogle Scholar
  13. 13.
    Kyle RF, Ellis TJ, Templeman DC (2005) Surgical treatment of intertrochanteric hip fractures with associated femoral neck fractures using a sliding hip screw. J Orthop Trauma 19(1):1–4CrossRefGoogle Scholar
  14. 14.
    Cleveland M, Bosworth DM, Thompson FR, Wilson HJ, Ishizuka T (1959) A ten-year analysis of intertrochanteric fractures of the femur. J Bone Joint Surg Am 41:1399–1408CrossRefGoogle Scholar
  15. 15.
    Madsen JE, Naess L, Aune AK, Alho A, Ekeland A, Strømsøe K (1998) Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the Gamma nail and compression hip screw. J Orthop Trauma 12(4):241–248CrossRefGoogle Scholar
  16. 16.
    Mavrogenis AF, Panagopoulos GN, Megaloikonomos PD, Igoumenou VG, Galanopoulos I, Vottis CT et al (2016) Complications after hip nailing for fractures. Orthopedics 39(1):e108–e116CrossRefGoogle Scholar
  17. 17.
    Murphy IG, Quinlan W, Kelly E (2008) Intraabdominal migration of a dynamic hip screw. Inj Extra 39:230–231CrossRefGoogle Scholar
  18. 18.
    George B, Hashmi FR, Barlas KJ, Grant CP (2006) Dynamic hip screw migration—an unusual case. Inj Extra 37:28–30CrossRefGoogle Scholar
  19. 19.
    Kuzyk PRT, Zdero R, Shah S, Olsen M, Waddell JP, Schemitsch EH (2012) Femoral head lag screw position for cephalomedullary nails: a biomechanical analysis. J Orthop Trauma 26(7):414–421CrossRefGoogle Scholar
  20. 20.
    De Bruijn K, den Hartog D, Tuinebreijer W, Roukema G (2012) Reliability of predictors for screw cutout in intertrochanteric hip fractures. J Bone Joint Surg Am 94(14):1266–1272CrossRefGoogle Scholar
  21. 21.
    Güven M, Yavuz U, Kadioğlu B, Akman B, Kilinçoğlu V, Unay K et al (2010) Importance of screw position in intertrochanteric femoral fractures treated by dynamic hip screw. Orthop Traumatol Surg Res OTSR 96(1):21–27CrossRefGoogle Scholar
  22. 22.
    Kubiak EN, Bong M, Park SS, Kummer F, Egol K, Koval KJ (2004) Intramedullary fixation of unstable intertrochanteric hip fractures: one or two lag screws. J Orthop Trauma 18(1):12–17CrossRefGoogle Scholar
  23. 23.
    Makki D, Mohamed AM, Gadiyar R, Patterson M (2013) Addition of an anti-rotation screw to the dynamic hip screw for femoral neck fractures. Orthopedics 36(7):e865–e868CrossRefGoogle Scholar
  24. 24.
    Su ET, DeWal H, Kummer FJ, Koval KJ (2003) The effect of an attachable lateral support plate on the stability of intertrochanteric fracture fixation with a sliding hip screw. J Trauma 55:504–508CrossRefGoogle Scholar
  25. 25.
    Hsu CE, Chiu YC, Tsai SH, Lin TC, Lee MH, Huang KC (2015) Trochanter stabilising plate improves treatment outcomes in AO/OTA 31-A2 intertrochanteric fractures with critical thin femoral lateral walls. Injury 46(6):1047–1053CrossRefGoogle Scholar
  26. 26.
    Reindl R, Harvey EJ, Berry GK, Rahme E, Canadian Orthopaedic Trauma Society (COTS) (2015) Intramedullary versus extramedullary fixation for unstable intertrochanteric fractures: a prospective randomized controlled trial. J Bone Joint Surg Am 97(23):1905–1912CrossRefGoogle Scholar

Copyright information

© Springer-Verlag France SAS, part of Springer Nature 2019

Authors and Affiliations

  1. 1.Department of Orthopedic SurgeryAsan Medical Center, Ulsan University, College of MedicineSongpa-Gu, SeoulRepublic of Korea

Personalised recommendations