Abstract
Recently, many facilities perform open wedge high tibial osteotomy (OWHTO) using artificial bone as a gap filler. However, there are many cases in which artificial bone is used without a clear purpose. We recommend a surgical technique to promote early synostosis between artificial bone and recipient bone due to mechanical support especially in the early stage after OWHTO. At our hospital, beta-tricalcium phosphate (β-TCP) with 60% porosity is used in OWHTO. Initially, a wedge-shaped block-type β-TCP, as large as possible, was inserted into the gap. However, from the standpoint of initial mechanical support, we changed the artificial bone size and created intentional holes. Furthermore, we removed air bubbles from β-TCP. We evaluated the synostosis on the basis of clinical results and diagnostic imaging. As a result of creating holes and removing air from the artificial bone, a trend toward faster synostosis was noted, especially at the early stage. No adverse events such as tibial plateau fracture, lateral cortical fracture, plate and screw failure and correction loss due to reducing the size of the artificial bone occurred, but placement of the artificial bone in contact with cortical bone and surface contact installation with the recipient bone tissue was important. When using artificial bone in OWHTO, holes formation and removal of air from the artificial bone are recommended for faster synostosis between artificial bone and recipient bone in the early stage after surgery. Artificial bone should be used, with attention to its positioning and shape, for efficient mechanical support.
Similar content being viewed by others
References
Lobenhoffer P, Agneskirchner JD (2003) Improvements in surgical technique of valgus high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 11:132–138
Staubli AE, De Simoni C, Babst R, Lobenhoffer P (2003) TomoFix: a new LCP-concept for open wedge osteotomy of the medial proximal tibia–early results in 92 cases. Injury 34(Suppl 2):B55–B62
Takeuchi R, Ishikawa H, Aratake M, Bito H, Saito I, Kumagai K, Akamatsu Y, Saito T (2009) Medial opening wedge high tibial osteotomy with early full weight bearing. Arthroscopy 25:46–53
Onodera J, Kondo E, Omizu N, Ueda D, Yagi T, Yasuda K (2014) Beta-tricalcium phosphate shows superior absorption rate and osteoconductivity compared to hydroxyapatite in open-wedge high tibial osteotomy. Knee Surg Sports Traumatol Arthrosc 22:2763–2770
Takeuchi R, Aratake M, Bito H, Saito I, Kumagai K, Ishikawa H, Akamatsu Y, Sasaki Y, Saito T (2008) Simultaneous bilateral opening-wedge high tibial osteotomy with early full weight bearing exercise. Knee Surg Sports Traumatol Arthrosc 16:1030–1037
Takeuchi R, Aratake M, Bito H, Saito I, Kumagai K, Hayashi R, Sasaki Y, Akamatsu Y, Ishikawa H, Amakado E, Aota Y, Saito T (2009) Clinical results and radiographical evaluation of opening wedge high tibial osteotomy for spontaneous osteonecrosis of the knee. Knee Surg Sports Traumatol Arthrosc 17:361–368
Takeuchi R, Bito H, Akamatsu Y, Shiraishi T, Morishita S, Koshino T, Saito T (2010) In vitro stability of open wedge high tibial osteotomy with synthetic bone graft. Knee 17(3):217–220
van Hemert WL, Willems K, Anderson PG, van Heerwaarden RJ, Wymenga AB (2004) Tricalcium phosphate granules or rigid wedge performs in open wedge high tibial osteotomy: a radiological study with a new evaluation system. Knee 11:451–456
Hernigou P, Roussignol X, Flouzat-Lachaniette CH, Filippini P, Guissou I, Poignard A (2010) Opening wedge tibial osteotomy for large varus deformity with Ceraver resorbable beta tricalcium phosphate wedges. Int Orthop 34:191–199
TohmaY Ohgushi H, Dohi Y, Shimaoka H, Ikeda Y, MizutaY Takakura Y (2003) Quantitative analysis of bone formation in the composites of cultured marrow cells and hydroxyapatite by X-ray computed tomography. Key Eng Mater 240–242:615–618
Okamoto M, Dohi Y, Ohgushi H, Shimaoka H, Ikeuchi M, Matsushima A, Yonemasu K, Hosoi H (2006) Influence of the porosity of hydroxyapatite ceramics on in vitro and in vivo bone formation by cultured rat bone marrow stromal cells. J Mater Sci Mater Med 17:327–336
Brosset T, Pasquier G, Migaud H, Gougeon F (2011) Opening wedge high tibial osteotomy performed without filling the defect but with locking plate fixation (TomoFix™) and early weight-bearing: prospective evaluation of bone union, precision and maintenance of correction in 51 cases. Orthop Traumatol Surg Res 97:705–711
Dejour H, Bonnin M (1994) Tibial translation after anterior cruciate ligament rupture. Two radiological tests compared. J Bone Joint Surg Br 76:745–749
Yanasse RH, Cavallari CE, Chaud FL, Hernandez AJ, Mizobuchi RR, Laraya MH (2009) Measurement of tibial slope angle after medial opening wedge high tibial osteotomy: case series. Sao Paulo Med J 127:34–39
Altermatt S, Schwöbel M, Pochon JP (1992) Operative treatment of solitary bone cysts with tricalcium phosphate ceramic. A 1 to 7 year follow-up. Eur J Pediatr Surg 2:180–182
Handschel J, Wiesmann HP, Stratmann U, Kleinheinz J, Meyer U, Joos U (2002) TCP is hardly resorbed and not osteoconductive in a non-loading calvarial model. Biomaterials 23:1689–1695
Neo M, Herbst H, Voigt CF, Gross UM (1998) Temporal and spatial patterns of osteoblast activation following implantation of beta-TCP particles into bone. J Biomed Mater Res 39:71–76
Liu G, Zhao L, Zhang W, Cui L, Liu W, Cao Y (2008) Repair of goat tibial defects with bone marrow stromal cells and beta-tricalcium phosphate. J Mater Sci Mater Med 19:2367–2376
Eggli PS, Müller W, Schenk RK (1988) Porous hydroxyapatite and tricalcium phosphate cylinders with two different pore size ranges implanted in the cancellous bone of rabbits. A comparative histomorphometric and histologic study of bony ingrowth and implant substitution. Clin Orthop Relat Res 232:127–138
Murphy CM, Haugh MG, O’Brien FJ (2010) The effect of mean pore size on cell attachment, proliferation and migration in collagen-glycosaminoglycan scaffolds for bone tissue engineering. Biomaterials 31:461–466
Torigoe I, Sotome S, Tsuchiya A, Yoshii T, Takahashi M, Kawabata S, Shinomiya K (2007) Novel cell seeding system into a porous scaffold using a modified low-pressure method to enhance cell seeding efficiency and bone formation. Cell Transpl 16:729–739
Masaoka T, Yoshii T, Yuasa M, Yamada T, Taniyama T, Torigoe I, Shinomiya K, Okawa A, Morita S, Sotome S (2016) Bone defect regeneration by a combination of a β-tricalcium phosphate scaffold and bone marrow stromal cells in a non-human primate model. Open Biomed Eng J 18(10):2–11
Yoshii T, Sotome S, Torigoe I, Tsuchiya A, Maehara H, Ichinose S, Shinomiya K (2009) Fresh bone marrow introduction into porous scaffolds using a simple low-pressure loading method for effective osteogenesis in a rabbit model. J Orthop Res 27:1–7
Zhou YF, Sae-Lim V, Chou AM, Hutmacher DW, Lim TM (2006) Does seeding density affect in vitro mineral nodules formation in novel composite scaffolds? J Biomed Mater Res A 78:183–193
Hasegawa T, Miwa M, Sakai Y, Niikura T, Lee SY, Oe K, Iwakura T, Kurosaka M, Komori T (2010) Efficient cell-seeding into scaffolds improves bone formation. J Dent Res 89:854–859
Torigoe I, Sotome S, Tsuchiya A, Yoshii T, Maehara H, Sugata Y, Ichinose S, Shinomiya K, Okawa A (2009) Bone regeneration with autologous plasma, bone marrow stromal cells, and porous beta-tricalcium phosphate in nonhuman primates. Tissue Eng Part A 15:1489–1499
Sago T, Mori Y, Takagi H, Iwata H, Murase K, Kawamura Y, Hirose H (2003) Local treatment of Dacron patch graft contaminated with Staphylococcus aureus using antibiotic-releasing porous apatite ceramic: an experimental study in the rabbit. J Vasc Surg 37:169–174
Itokazu M, Yang W, Aoki T, Ohara A, Kato N (1998) Synthesis of antibiotic-loaded interporous hydroxyapatite blocks by vacuum method and in vitro drug release testing. Biomaterials 19:817–819
Rodner CM, Adams DJ, Diaz-Doran V, Tate JP, Santangelo SA, Mazzocca AD, Arciero RA (2006) Medial opening wedge tibial osteotomy and the sagittal plane: the effect of increasing tibial slope on tibiofemoral contact pressure. Am J Sports Med 34:1431–1441
Ogawa H, Matsumoto K, Ogawa T, Takeuchi K, Akiyama H (2016) Effect of wedge insertion angle on posterior tibial slope in medial opening wedge high tibial osteotomy. Orthop J Sports Med 4(2):2325967116630748
Funding
This work was supported in part by a Grant-in-Aid for Scientific Research (C) from the Ministry of Education, Culture, Sports, Science and Technology, JSPS KAKENHI Grant Number JP17K10980.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical approval
This study was approved by the Institutional Review Board director of National Hospital Organization Nara Medical Centre. The patient provided permission to publish this clinical case, and the identity of the patient has been protected.
Informed consent
Informed consent was obtained from all the patients to present their medical data.
Rights and permissions
About this article
Cite this article
Tohma, Y., Takeuchi, R. & Tanaka, Y. Advantages of creation of holes and removal of air in artificial bone for early bone formation when used artificial bone as a gap filler in open wedge high tibial osteotomy. Eur J Orthop Surg Traumatol 29, 131–137 (2019). https://doi.org/10.1007/s00590-018-2286-8
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00590-018-2286-8