Skip to main content

Advertisement

Log in

Radiographic and clinical assessment on the accuracy and complications of C1 anterior lateral mass and C2 anterior pedicle screw placement in the TARP-III procedure: a study of 106 patients

  • Original Article
  • Published:
European Spine Journal Aims and scope Submit manuscript

Abstract

Purpose

To investigate the (1) radiographic and clinical accuracy of C1 anterior lateral mass screw (C1ALMS) and C2 anterior pedicle screw (C2APS) placement in the transoral atlantoaxial reduction plate (TARP)-III procedure, (2) screw insertion-associated clinical complications and (3) fusion status between C1 and C2.

Methods

Radiographic and clinical data were obtained from the electronic medical record system. Studies were carried out to assess the accuracy of C1ALMS and C2APS placement, the screw insertion-associated clinical complications and the fusion status between C1 and C2. Placement of the screws was assessed using the modified All India Institute of Medical Sciences outcome-based classification.

Results

Two-hundred and twelve C1ALMS and 207 C2APS in 106 patients were assessed. The ideal accurate rates were 92.0 % (195) and 53.1 % (110), and the acceptable accurate rates were 97.6 % (207) and 87.0 % (180), respectively. One patient died postoperatively due to C2 screw misplacement. There were no symptoms of neurologic and vertebral artery injuries in the rest of the patients. 102 patients (97.1 %) achieved solid fusion between C1 and C2. No instrumentation failure due to delayed union or nonunion was observed.

Conclusion

C1ALMS placement in TARP-III procedures appears to be safe. The cortical breach rate of C2APS is high though clinically the neurovascular complication rate is similar to that of posterior atlantoaxial procedures. Advanced navigation strategies may help improve the accuracy of C2APS placement and decrease potential complications.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6

Similar content being viewed by others

References

  1. Wang C, Yan M, Zhou HT, Wang SL, Dang GT (2006) Open reduction of irreducible atlantoaxial dislocation by transoral anterior atlantoaxial release and posterior internal fixation. Spine (Phila Pa 1976) 31:E306–E313. doi:10.1097/01.brs.0000217686.80327.e4

    Article  Google Scholar 

  2. Visocchi M, Pietrini D, Tufo T, Fernandez E, Di Rocco C (2009) Pre-operative irreducible C1–C2 dislocations: intra-operative reduction and posterior fixation. The “always posterior strategy”. Acta Neurochir (Wien) 151(551–559):560. doi:10.1007/s00701-009-0271-z

    Google Scholar 

  3. Schmelzle R, Harms J, Stoltze D (1987) Osteosynthesen im occipito-cervicalem übergang vom transoralen Zugang aus. XVII SICOT world congress abstracts. Demeter-Verlag, Munich, pp 27–28

    Google Scholar 

  4. Kandziora F, Mittlmeier T, Kerschbaumer F (1999) Stage-related surgery for cervical spine instability in rheumatoid arthritis. Eur Spine J 8:371–381

    Article  CAS  PubMed Central  PubMed  Google Scholar 

  5. Wang C, Wang S (2009) Visocchi M, Pietrini D, Tufo T, Fernandez E, Di Rocco C (2009) Pre-operative irreducible C1–C2 dislocations: intra-operative reduction and posterior fixation. The “always posterior strategy”. Acta Neurochir 151(5): 551–560; discussion. Acta Neurochir (Wien) 151:1329–1331. doi:10.1007/s00701-009-0477-0

    Article  Google Scholar 

  6. Yin Q, Ai F, Zhang K, Chang Y, Xia H, Wu Z, Quan R, Mai X, Liu J (2005) Irreducible anterior atlantoaxial dislocation: one-stage treatment with a transoral atlantoaxial reduction plate fixation and fusion. Report of 5 cases and review of the literature. Spine (Phila Pa 1976) 30:E375–E381

    Article  Google Scholar 

  7. Yin QS, Ai FZ, Zhang K, Mai XH, Xia H, Wu ZH (2010) Transoral atlantoaxial reduction plate internal fixation for the treatment of irreducible atlantoaxial dislocation: a 2- to 4-year follow-up. Orthop Surg 2:149–155. doi:10.1111/j.1757-7861.2010.00077.x

    Article  PubMed  Google Scholar 

  8. Ai FZ, Yin QS, Xu DC, Xia H, Wu ZH, Mai XH (2011) Transoral atlantoaxial reduction plate internal fixation with transoral transpedicular or articular mass screw of c2 for the treatment of irreducible atlantoaxial dislocation: two case reports. Spine (Phila Pa 1976) 36:E556–E562. doi:10.1097/BRS.0b013e3181f57191

    Article  Google Scholar 

  9. Xu J, Yin Q, Xia H, Wu Z, Ma X, Zhang K, Wang Z, Yang J, Ai F, Wang J, Liu J, Mai X (2013) New clinical classification system for atlantoaxial dislocation. Orthopedics 36:e95–e100. doi:10.3928/01477447-20121217-25

    Article  PubMed  Google Scholar 

  10. Upendra BN, Meena D, Chowdhury B, Ahmad A, Jayaswal A (2008) Outcome-based classification for assessment of thoracic pedicular screw placement. Spine (Phila Pa 1976) 33:384–390. doi:10.1097/BRS.0b013e3181646ba1

    Article  Google Scholar 

  11. Bransford RJ, Russo AJ, Freeborn M, Nguyen QT, Lee MJ, Chapman JR, Bellabarba C (2011) Posterior C2 instrumentation: accuracy and complications associated with four techniques. Spine (Phila Pa 1976) 36:E936–E943. doi:10.1097/BRS.0b013e3181fdaf06

    Article  Google Scholar 

  12. Kandziora F, Pflugmacher R, Ludwig K, Duda G, Mittlmeier T, Haas NP (2002) Biomechanical comparison of four anterior atlantoaxial plate systems. J Neurosurg 96:313–320

    PubMed  Google Scholar 

  13. Kandziora F, Schulze-Stahl N, Khodadadyan-Klostermann C, Schroder R, Mittlmeier T (2001) Screw placement in transoral atlantoaxial plate systems: an anatomical study. J Neurosurg 95:80–87

    CAS  PubMed  Google Scholar 

  14. Harms J, Melcher RP (2001) Posterior C1–C2 fusion with polyaxial screw and rod fixation. Spine (Phila Pa 1976) 26:2467–2471

    Article  CAS  Google Scholar 

  15. Goel A, Desai KI, Muzumdar DP (2002) Atlantoaxial fixation using plate and screw method: a report of 160 treated patients. Neurosurgery 51(1351–1356):1356–1357

    Google Scholar 

  16. Ondra SL, Marzouk S, Ganju A, Morrison T, Koski T (2006) Safety and efficacy of C2 pedicle screws placed with anatomic and lateral C-arm guidance. Spine (Phila Pa 1976) 31:E263–E267. doi:10.1097/01.brs.0000214882.34674.be

    Article  Google Scholar 

  17. Stulik J, Vyskocil T, Sebesta P, Kryl J (2007) Atlantoaxial fixation using the polyaxial screw-rod system. Eur Spine J 16:479–484. doi:10.1007/s00586-006-0241-6

    Article  PubMed Central  PubMed  Google Scholar 

  18. Aryan HE, Newman CB, Nottmeier EW, Acosta FJ, Wang VY, Ames CP (2008) Stabilization of the atlantoaxial complex via C-1 lateral mass and C-2 pedicle screw fixation in a multicenter clinical experience in 102 patients: modification of the Harms and Goel techniques. J Neurosurg Spine 8:222–229. doi:10.3171/SPI/2008/8/3/222

    Article  PubMed  Google Scholar 

  19. Yeom JS, Buchowski JM, Park KW, Chang BS, Lee CK, Riew KD (2008) Undetected vertebral artery groove and foramen violations during C1 lateral mass and C2 pedicle screw placement. Spine (Phila Pa 1976) 33:E942–E949. doi:10.1097/BRS.0b013e3181870441

    Article  Google Scholar 

  20. Parker SL, McGirt MJ, Garces-Ambrossi GL, Mehta VA, Sciubba DM, Witham TF, Gokaslan ZL, Wolinksy JP (2009) Translaminar versus pedicle screw fixation of C2: comparison of surgical morbidity and accuracy of 313 consecutive screws. Neurosurgery 64(343–348):348–349. doi:10.1227/01.NEU.0000338955.36649.4F

    Google Scholar 

  21. Sciubba DM, Noggle JC, Vellimana AK, Alosh H, McGirt MJ, Gokaslan ZL, Wolinsky JP (2009) Radiographic and clinical evaluation of free-hand placement of C-2 pedicle screws. Clinical article. J Neurosurg Spine 11:15–22. doi:10.3171/2009.3.SPINE08166

    Article  PubMed  Google Scholar 

  22. Wang S, Wang C, Wood KB, Yan M, Zhou H (2011) Radiographic evaluation of the technique for C1 lateral mass and C2 pedicle screw fixation in three hundred nineteen cases. Spine (Phila Pa 1976) 36:3–8. doi:10.1097/BRS.0b013e3181c97dc7

    Google Scholar 

  23. Alosh H, Parker SL, McGirt MJ, Gokaslan ZL, Witham TF, Bydon A, Wolinsky JP, Sciubba DM (2010) Preoperative radiographic factors and surgeon experience are associated with cortical breach of C2 pedicle screws. J Spinal Disord Tech 23:9–14. doi:10.1097/BSD.0b013e318194e746

    Article  PubMed  Google Scholar 

  24. Bransford RJ, Freeborn MA, Russo AJ, Nguyen QT, Lee MJ, Chapman JR, Bellabarba C (2012) Accuracy and complications associated with posterior C1 screw fixation techniques: a radiographic and clinical assessment. Spine J 12:231–238. doi:10.1016/j.spinee.2012.02.011

    Article  PubMed  Google Scholar 

  25. Fensky F, Kueny RA, Sellenschloh K, Puschel K, Morlock MM, Rueger JM, Lehmann W, Huber G, Hansen-Algenstaedt N (2014) Biomechanical advantage of C1 pedicle screws over C1 lateral mass screws: a cadaveric study. Eur Spine J 23:724–731. doi:10.1007/s00586-013-3143-4

    Article  PubMed  Google Scholar 

  26. Yin Q, Xia H, Wu Z, Smith WD Transoral atlantoaxial reduction and plate fixation. Saint Louis, Missouri

  27. Ma W, Xu N, Hu Y, Li G, Zhao L, Sun S, Jiang W, Liu G, Gu Y, Liu J (2013) Unstable atlas fracture treatment by anterior plate C1-ring osteosynthesis using a transoral approach. Eur Spine J 22:2232–2239. doi:10.1007/s00586-013-2870-x

    Article  PubMed  Google Scholar 

  28. Lesoin F, Autricque A, Franz K, Villette L, Jomin M (1987) Transcervical approach and screw fixation for upper cervical spine pathology. Surg Neurol 27:459–465

    Article  CAS  PubMed  Google Scholar 

  29. Sen MK, Steffen T, Beckman L, Tsantrizos A, Reindl R, Aebi M (2005) Atlantoaxial fusion using anterior transarticular screw fixation of C1–C2: technical innovation and biomechanical study. Eur Spine J 14:512–518. doi:10.1007/s00586-004-0823-0

    Article  PubMed Central  PubMed  Google Scholar 

  30. Wang J, Zhou Y, Zhang Z, Li C, Zheng W, Zhang Y (2012) Minimally invasive anterior transarticular screw fixation and microendoscopic bone graft for atlantoaxial instability. Eur Spine J 21:1568–1574. doi:10.1007/s00586-012-2153-y

    Article  PubMed Central  PubMed  Google Scholar 

Download references

Acknowledgments

Grants provided by Key Project of the Twelfth Five-year Project of Military Medicine (BWS11C065) and Science and Technology Project of Guangdong Province (2012B031800187).

Conflict of interest

None.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Qingshui Yin.

Additional information

X. Li and F. Ai contributed equally to this work.

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Li, X., Ai, F., Xia, H. et al. Radiographic and clinical assessment on the accuracy and complications of C1 anterior lateral mass and C2 anterior pedicle screw placement in the TARP-III procedure: a study of 106 patients. Eur Spine J 23, 1712–1719 (2014). https://doi.org/10.1007/s00586-014-3353-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00586-014-3353-4

Keywords

Navigation