Abstract

The present method of C2 laminar screw placement relies on anatomical landmarks for screw placement. Placement of C2 laminar screws using drill template has not been described in the literature. The authors reported on their experience with placement of C2 laminar screws using a novel computer-assisted drill guide template in nine patients undergoing posterior occipito-cervical fusion. CT scan of C2 vertebrae was performed. 3D model of C2 vertebrae was reconstructed by software MIMICS 10.01. The 3D vertebral model was then exported in STL format, and opened in a workstation running software UG imageware12.0 for determining the optimal laminar screw size and orientation. A virtual navigational template was established according to the laminar anatomic trait. The physical vertebrae and navigational template were manufactured using rapid prototyping. The navigational template was sterilized and used intraoperative to assist the placement of laminar screw. Overall, 19 C2 laminar screws were placed and the accuracy of screw placement was confirmed with postoperative X-ray and CT scanning. There were not complications of related screws insertion. Average follow-up was 9 months (range 4–13 months), 77.8% of the patients exhibited improvement in their myelopathic symptoms; in 22.2% the symptoms were unchanged. Postoperative computed tomographic (CT) scanning was available for allowing the evaluation of placement of thirteen C2 laminar screws, all of which were in good position with no spinal canal violation. This study shows a patient-specific template technique that is easy to use, can simplify the surgical act and generates highly accurate C2 laminar screw placement. Advantages of this technology over traditional techniques include planning of the screw trajectory is done completely in the presurgical period as well as the ability to size the screw to the patient’s anatomy.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3

Similar content being viewed by others

References

  1. Berry E, Cuppone M, Porada S, Millner PA, Rao A, Chiverton N, Seedhom BB (2005) Personalised image-based templates for intra-operative guidance. Proc Inst Mech Eng [H] 219:111–118. doi:10.1243/095441105X9273

    CAS  Google Scholar 

  2. Brooks AL, Jenkins EB (1978) Atlanto-axial arthrodesis by the wedge compression method. J Bone Joint Surg Am 60:279–284

    PubMed  CAS  Google Scholar 

  3. Coric D, Branch CL Jr, Wilson JA, Robinson JC (1996) Arteriovenous fistula as a complication of C1–2 transarticular screw fixation: case report and review of the literature. J Neurosurg 85:340–343

    Article  PubMed  CAS  Google Scholar 

  4. Dickman CA, Sonntag VK, Papadopoulos SM, Hadley MN (1991) The interspinous method of posterior atlantoaxial arthrodesis. J Neurosurg 74:190–198

    Article  PubMed  CAS  Google Scholar 

  5. Ebraheim N, Rollins JR Jr, Xu R, Jackson WT (1996) Anatomic consideration of C2 pedicle screw placement. Spine 21:691–695. doi:10.1097/00007632-199603150-00005

    Article  PubMed  CAS  Google Scholar 

  6. Goffin J, Van Brussel K, Martens K, Vander Sloten J, Van Audekercke R, Smet MH (2001) Three-dimensional computed tomography-based, personalized drill guide for posterior cervical stabilization at C1–2. Spine 26:1343–1347. doi:10.1097/00007632-200106150-00017

    Article  PubMed  CAS  Google Scholar 

  7. Gorek J, Acaroglu E, Berven S, Yousef A, Puttlitz CM (2005) Constructs incorporating intralaminar C2 screws provide rigid stability for atlantoaxial fixation. Spine 30:1513–1518. doi:10.1097/01.brs.0000167827.84020.49

    Article  PubMed  Google Scholar 

  8. Grob D, Jeanneret B, Aebi M, Markwalder TM (1991) Atlanto-axial fusion with transarticular screw fixation. J Bone Joint Surg Br 73:972–976

    PubMed  CAS  Google Scholar 

  9. Hott JS, Papadopoulos SM, Theodore N, Dickman CA, Sonntag VK (2004) Intraoperative Iso-C C-arm navigation in cervical spinal surgery: review of the first 52 cases. Spine 29:2856–2860. doi:10.1097/01.brs.0000147742.20637.49

    Article  PubMed  Google Scholar 

  10. Igarashi T, Kikuchi S, Sato K, Kayama S, Otani K (2003) Anatomic study of the axis for surgical planning of transarticular screw fixation. Clin Orthop Relat Res 408:162–166. doi:10.1097/00003086-200303000-00020

    Article  PubMed  Google Scholar 

  11. Jeanneret B, Magerl F (1992) Primary posterior fusion C1–2 in odontoid fractures: indications, technique, and results of transarticular screw fixation technique. J Spinal Disord 5:464–475. doi:10.1097/00002517-199212000-00012

    Article  PubMed  CAS  Google Scholar 

  12. Kamimura M, Ebara S, Itoh H, Tateiwa Y, Kinoshita T, Takaoka K (2000) Cervical pedicle screw insertion: assessment of safety and accuracy with computer-assisted image guidance. J Spinal Disord 13:218–224. doi:10.1097/00002517-200006000-00004

    Article  PubMed  CAS  Google Scholar 

  13. Kothe R, Matthias Strauss J, Deuretzbacher G, Hemmi T, Lorenzen M, Wiesner L (2001) Computer navigation of parapedicular screw fixation in the thoracic spine: a cadaver study. Spine 26:E496–E501. doi:10.1097/00007632-200111010-00019

    Article  PubMed  CAS  Google Scholar 

  14. Lapsiwala SB, Anderson PA, Oza A, Resnick DK (2006) Biomechanical comparison of four C1 to C2 rigid fixative techniques: anterior transarticular, posterior transarticular, C1 to C2 pedicle, and C1 to C2 intralaminar screws. Neurosurgery 58:516–521

    PubMed  Google Scholar 

  15. Lehman RA Jr, Sasso RC, Helgeson MD, Dmitriev AE, Gill NW, Rosner MR, Riew KD (2007) Accuracy of intraoperative plain radiographs to detect violations of intralaminar screws placed into the C2 vertebrae: a reliability study. Spine 32:3036–3040. doi:10.1097/BRS.0b013e31815cdab9

    Article  PubMed  Google Scholar 

  16. Leonard JR, Wright NM (2006) Pediatric atlantoaxial fixation with bilateral, crossing C-2 translaminar screws: technical note. J Neurosurg 104:59–63

    PubMed  Google Scholar 

  17. Mac-Thiong JM, Labelle H, Rooze M, Feipel V, Aubin CE (2003) Evaluation of a transpedicular drill guide for pedicle screw placement in the thoracic spine. Eur Spine J 12:542–547. doi:10.1007/s00586-003-0549-4

    Article  PubMed  Google Scholar 

  18. Madawi AA, Casey AT, Solanki GA, Tuite G, Veres R, Crockard HA (1997) Radiological and anatomical evaluation of the atlantoaxial transarticular screw fixation technique. J Neurosurg 86:961–968

    Article  PubMed  CAS  Google Scholar 

  19. Mandel IM, Kambach BJ, Petersilge CA, Johnstone B, Yoo JU (2000) Morphologic considerations of C2 isthmus dimensions for the placement of transarticular screws. Spine 25:1542–1547. doi:10.1097/00007632-200006150-00014

    Article  PubMed  CAS  Google Scholar 

  20. Marcotte P, Dickman CA, Sonntag VK, Karahalios DG, Drabier J (1993) Posterior atlantoaxial facet screw fixation. J Neurosurg 79:234–237

    Article  PubMed  CAS  Google Scholar 

  21. Nottmeier EW, Foy AB (2008) Placement of C2 laminar screws using three-dimensional fluoroscopy-based image guidance. Eur Spine J 17:610–615. doi:10.1007/s00586-007-0557-x

    Article  PubMed  Google Scholar 

  22. Owen BD, Christensen GE, Reinhardt JM, Ryken TC (2007) Rapid prototype patient-specific drill template for cervical pedicle screw placement. Comput Aided Surg 12:303–308. doi:10.1080/10929080701662826

    Article  PubMed  Google Scholar 

  23. Radermacher K, Portheine F, Anton M, Zimolong A, Kaspers G, Rau G, Staudte HW (1998) Computer assisted orthopaedic surgery with image based individual templates. Clin Orthop Relat Res 354:28–38. doi:10.1097/00003086-199809000-00005

    Article  PubMed  Google Scholar 

  24. Stillerman CB, Wilson JA (1993) Atlanto-axial stabilization with posterior transarticular screw fixation: technical description and report of 22 cases. Neurosurgery 32:948–955. doi:10.1097/00006123-199306000-00011

    Article  PubMed  CAS  Google Scholar 

  25. Villavicencio AT, Burneikiene S, Bulsara KR, Thramann JJ (2005) Utility of computerized isocentric fluoroscopy for minimally invasive spinal surgical techniques. J Spinal Disord Tech 18:369–375. doi:10.1097/01.bsd.0000168511.67189.64

    Article  PubMed  Google Scholar 

  26. Wang MY (2006) C2 crossing laminar screws: cadaveric morphometric analysis. Neurosurgery 59:84–88. doi:10.1227/01.NEU.0000219900.24467.32

    Article  Google Scholar 

  27. Wright NM (2004) Posterior C2 fixation using bilateral, crossing C2 laminar screws: case series and technical note. J Spinal Disord Tech 17:158–162

    PubMed  Google Scholar 

  28. Wright NM (2005) Translaminar rigid screw fixation of the axis: technical note. J Neurosurg Spine 3:409–414

    Article  PubMed  Google Scholar 

  29. Wright NM, Lauryssen C (1998) Vertebral artery injury in C1–2 transarticular screw fixation: results of a survey of the AANS/CNS section on disorders of the spine and peripheral nerves: American Association of Neurological Surgeons/Congress of Neurological Surgeons. J Neurosurg 88:634–640

    Article  PubMed  CAS  Google Scholar 

Download references

Acknowledgments

The authors would like to thank Dr. You-hua Cheng for his assistance with the CT data collection.

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Sheng Lu.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Lu, S., Xu, Y.Q., Zhang, Y.Z. et al. A novel computer-assisted drill guide template for placement of C2 laminar screws. Eur Spine J 18, 1379–1385 (2009). https://doi.org/10.1007/s00586-009-1051-4

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00586-009-1051-4

Keywords

Navigation