Abstract

Introduction

To date, only a few studies have compared radial head prostheses (RHP) and their different anchoring principles. The aim of this study was to characterize concomitant injuries, necessary adjuvant procedures, complications, and radiological findings after implantation of two different types of RHP.

Methods

Sixty-six patients with radial head fractures were treated with MoPyC (Tornier/France, 50 mm stem, monopolar) or SBI rHead prostheses (Small Bone Innovations/USA, 22-mm stem, bipolar) and followed up over 42 months (16–64 months). Primary objective was the detection of different loosening and explantation rates. In addition to the revision rate and the reasons for revision, we also used radiological findings to assess the dynamics of lysis phenomena.

Results

Thirty-five patients (mean age 48 years; 22–73 years) were treated with the MoPyC, and 31 patients (mean age 47 years, 19–69 years) with the rHead prosthesis. Of these, 98% had a Mason 3 or 4 type of radial head fracture, and 94% showed concomitant injuries, which were addressed in 89% of cases by adjuvant procedures. The surgical revision rate was 20% (rHead 23%; MoPyC 18%). Significantly more of the rHead prostheses had to be explanted compared to MoPyC prostheses because of painful loosening (16% vs. 3%; p = 0.029). Predictors of subsequent loosening were significant radiolucent lines in the RHP over the first six months and an increase in width by two and a half times within the first 50 days after implantation.

Conclusion

Complex radial head fractures are frequent and difficult to treat. The monopolar long-stemmed prosthesis showed significantly lower rates of painful loosening and explanation rates than the bipolar short-stemmed prosthesis.

Keywords

MoPyC rHead Radial head prostheses Bipolar RHP Monopolar RHP 

Notes

Compliance with ethical standards

Study is based on institutional review board (IRB) approval. The study was approved by our institutional review board (IRB Approval LAEKH-FF-1316) and all patients provided informed consent.

Conflict of interest

No benefits in any form have been received or will be received from a commercial party related directly or indirectly to the subject of this article. On behalf of all authors, the corresponding author states that there is no conflict of interest.

Supplementary material

264_2018_4173_MOESM1_ESM.pdf (1.7 mb)
ESM 1 (PDF 1.72 mb)

References

  1. 1.
    Itamura J, Roidis N, Mirzayan R, Vaishnav S, Learch T, Shean C (2005) Radial head fractures: MRI evaluation of associated injuries. J Shoulder Elb Surg 14(4):421–424CrossRefGoogle Scholar
  2. 2.
    Morrey BF, An K-N (2005) Stability of the elbow: osseous constraints. J Shoulder Elb Surg 14(1):S174–S178CrossRefGoogle Scholar
  3. 3.
    Schmidt-Horlohe K, Siebenlist S, Stöckle U, Pichl J, Hoffmann R (2011) Fractures of the radial head and neck. Zeitschrift fur Orthopadie und Unfallchirurgie 149(6):e69–e86 quiz e87–68CrossRefPubMedGoogle Scholar
  4. 4.
    Ikeda M, Sugiyama K, Kang C, Takagaki T, Oka Y (2005) Comminuted fractures of the radial head. Comparison of resection and internal fixation. J Bone Joint Surg Am 87(1):76–84.  https://doi.org/10.2106/JBJS.C.01323 CrossRefPubMedGoogle Scholar
  5. 5.
    Al-Burdeni S, Abuodeh Y, Ibrahim T, Ahmed G (2015) Open reduction and internal fixation versus radial head arthroplasty in the treatment of adult closed comminuted radial head fractures (modified Mason type III and IV). Int Orthop 39(8):1659–1664CrossRefPubMedGoogle Scholar
  6. 6.
    Beingessner DM, Dunning CE, Gordon KD, Johnson JA, King GJ (2004) The effect of radial head excision and arthroplasty on elbow kinematics and stability. J Bone Joint Surg Am 86(8):1730–1739CrossRefPubMedGoogle Scholar
  7. 7.
    Burkhart KJ, Wegmann K, Ries C, Müller LP (2013) Endoprosthetics of acute radial head fractures. Unfallchirurg 116(8):698–707.  https://doi.org/10.1007/s00113-013-2412-3 CrossRefPubMedGoogle Scholar
  8. 8.
    Duckworth AD, Clement ND, Jenkins PJ, Aitken SA, Court-Brown CM, McQueen MM (2012) The epidemiology of radial head and neck fractures. J Hand Surg 37(1):112–119CrossRefGoogle Scholar
  9. 9.
    Heijink A, Kodde IF, Mulder PGH, Veltman ES, Kaas L, van den Bekerom MPJ, Eygendaal D (2016) Radial head arthroplasty. Syst Rev 4(10).  https://doi.org/10.2106/jbjs.rvw.15.00095
  10. 10.
    Morrey BF, Sanchez-Sotelo J (2009) The elbow and its disorders. Elsevier Health Sciences, AmsterdamGoogle Scholar
  11. 11.
    Schiffern A, Bettwieser SP, Porucznik CA, Crim JR, Tashjian RZ (2011) Proximal radial drift following radial head resection. J Shoulder Elb Surg 20(3):426–433.  https://doi.org/10.1016/j.jse.2010.11.008 CrossRefGoogle Scholar
  12. 12.
    van Riet RP, Morrey BF (2010) Delayed valgus instability and proximal migration of the radius after radial head prosthesis failure. J Shoulder Elb Surg 19(7):e7–e10.  https://doi.org/10.1016/j.jse.2010.04.046 CrossRefGoogle Scholar
  13. 13.
    Li N, Chen S (2014) Open reduction and internal-fixation versus radial head replacement in treatment of Mason type III radial head fractures. Eur J Orthop Surg Traumatol 24(6):851–855CrossRefPubMedGoogle Scholar
  14. 14.
    Laumonerie P, Reina N, Ancelin D, Delclaux S, Tibbo M, Bonnevialle N, Mansat P (2017) Mid-term outcomes of 77 modular radial head prostheses. Bone Joint J 99-B(9):1197–1203.  https://doi.org/10.1302/0301-620X.99B9.BJJ-2016-1043.R2 CrossRefPubMedGoogle Scholar
  15. 15.
    Fowler JR, Henry SE, Xu P, Goitz RJ (2016) Outcomes following radial head arthroplasty. Orthopedics 39(3):153–160CrossRefPubMedGoogle Scholar
  16. 16.
    Marsh JP, Grewal R, Faber KJ, Drosdowech DS, Athwal GS, King GJ (2016) Radial head fractures treated with modular metallic radial head replacement: outcomes at a mean follow-up of eight years. JBJS 98(7):527–535CrossRefGoogle Scholar
  17. 17.
    Yalcinkaya M, Bagatur AE, Erdogan S, Zorer G (2013) Resection arthroplasty for Mason type III radial head fractures yield good clinical but poor radiological results in the long term. Orthopedics 36(11):e1358–e1364CrossRefPubMedGoogle Scholar
  18. 18.
    Schnetzke M, Aytac S, Deuss M, Studier-Fischer S, Swartman B, Muenzberg M, Gruetzner P-A, Guehring T (2014) Radial head prosthesis in complex elbow dislocations: effect of oversizing and comparison with ORIF. Int Orthop 38(11):2295–2301CrossRefPubMedGoogle Scholar
  19. 19.
    Flinkkilä T, Kaisto T, Sirniö K, Hyvönen P, Leppilahti J (2012) Short-to mid-term results of metallic press-fit radial head arthroplasty in unstable injuries of the elbow. J Bone Joint Surg (Br) 94(6):805–810.  https://doi.org/10.1302/0301-620X.94B6.28176 CrossRefGoogle Scholar
  20. 20.
    Doornberg JN, Parisien R, van Duijn PJ, Ring D (2007) Radial head arthroplasty with a modular metal spacer to treat acute traumatic elbow instability. JBJS 89(5):1075–1080CrossRefGoogle Scholar
  21. 21.
    Popovic N, Lemaire R, Georis P, Gillet P (2007) Midterm results with a bipolar radial head prosthesis: radiographic evidence of loosening at the bone-cement interface. J Bone Joint Surg Am 89(11):2469–2476PubMedGoogle Scholar
  22. 22.
    Van Riet RP, Van Glabbeek F, Neale PG, Bortier H, An K-N, O’Driscoll SW (2003) The noncircular shape of the radial head. J Hand Surg 28(6):972–978CrossRefGoogle Scholar
  23. 23.
    G C, F C, N M, E T, F B (2002) Biometry of the radial head: biomechanical implications in pronation and supination. Surg Radiol Anat 24(5):295–301CrossRefGoogle Scholar
  24. 24.
    Chen H, Wang Z, Shang Y (2017) Clinical and radiographic outcomes of unipolar and bipolar radial head prosthesis in patients with radial head fracture: a systemic review and meta-analysis. J Investig Surg 13:1–7Google Scholar
  25. 25.
    Nestorson J, Josefsson PO, Adolfsson L (2017) A radial head prosthesis appears to be unnecessary in Mason-IV fracture dislocation. Acta Orthop 88(3):315–319CrossRefPubMedPubMedCentralGoogle Scholar
  26. 26.
    Van Hoecke E, Van De Vijver A, Van Glabbeek F, Gielen J (2016) Long term results after bipolar radial head arthroplasty. Acta Orthop Belg 82(2):382–388PubMedGoogle Scholar
  27. 27.
    Doornberg JN, Linzel DS, Zurakowski D, Ring D (2006) Reference points for radial head prosthesis size. J Hand Surg 31(1):53–57CrossRefGoogle Scholar
  28. 28.
    Doornberg JN, Van Duijn PJ, Linzel D, Ring DC, Zurakowski D, Marti RK, Kloen P (2007) Surgical treatment of intra-articular fractures of the distal part of the humerus. J Bone Joint Surg Am 89(7):1524–1532Google Scholar
  29. 29.
    Neuhaus V, Christoforou DC, Kachooei AR, Jupiter JB, Ring DC, Mudgal CS (2015) Radial head prosthesis removal: a retrospective case series of 14 patients. Arch Bone Joint Surg 3(2):88PubMedGoogle Scholar
  30. 30.
    Grewal R, MacDermid JC, Faber KJ, Drosdowech DS, King GJ (2006) Comminuted radial head fractures treated with a modular metallic radial head arthroplasty. J Bone Joint Surg 88(10):2192–2200PubMedGoogle Scholar
  31. 31.
    Morgan SJ, Groshen SL, Itamura JM, Shankwiler J, Brien WW, Kuschner SH (1997) Reliability evaluation of classifying radial head fractures by the system of Mason. Bull Hosp Jt Dis 56(2):95–98PubMedGoogle Scholar
  32. 32.
    Gruen TA, Mcneice GM, Amstutz HC (1979) “Modes of failure” of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res (141):17–27Google Scholar
  33. 33.
    Gauci MO, Winter M, Dumontier C, Bronsard N, Allieu Y (2016) Clinical and radiologic outcomes of pyrocarbon radial head prosthesis: midterm results. J Shoulder Elb Surg 25(1):98–104.  https://doi.org/10.1016/j.jse.2015.08.033 CrossRefGoogle Scholar
  34. 34.
    Berschback JC, Lynch TS, Kalainov DM, Wysocki RW, Merk BR, Cohen MS (2013) Clinical and radiographic comparisons of two different radial head implant designs. J Shoulder Elb Surg 22(8):1108–1120.  https://doi.org/10.1016/j.jse.2013.02.011 CrossRefGoogle Scholar
  35. 35.
    Rotini R, Marinelli A, Guerra E, Bettelli G, Cavaciocchi M (2012) Radial head replacement with unipolar and bipolar SBi system: a clinical and radiographic analysis after a 2-year mean follow-up. Musculoskelet Surg 96(1):69–79CrossRefGoogle Scholar
  36. 36.
    Van Riet R, Sanchez-Sotelo J, Morrey B (2010) Failure of metal radial head replacement. Bone Joint J 92(5):661–667Google Scholar
  37. 37.
    Sarris IK, Kyrkos MJ, Galanis NN, Papavasiliou KA, Sayegh FE, Kapetanos GA (2012) Radial head replacement with the MoPyC pyrocarbon prosthesis. J Shoulder Elb Surg 21(9):1222–1228.  https://doi.org/10.1016/j.jse.2011.12.004 CrossRefGoogle Scholar
  38. 38.
    Chanlalit C, Shukla DR, Fitzsimmons JS, An K-N, O'Driscoll SW (2012) The biomechanical effect of prosthetic design on radiocapitellar stability in a terrible triad model. J Orthop Trauma 26(9):539–544CrossRefPubMedGoogle Scholar
  39. 39.
    Pomianowski S, Morrey BF, Neale PG, Park MJ, O'Driscoll SW, An KN (2001) Contribution of monoblock and bipolar radial head prostheses to valgus stability of the elbow. J Bone Joint Surg Am 83(12):1829–1834CrossRefPubMedGoogle Scholar
  40. 40.
    Moon JG, Berglund LJ, Zachary D, An KN, O'Driscoll SW (2009) Radiocapitellar joint stability with bipolar versus monopolar radial head prostheses. J Shoulder Elb Surg 18(5):779–784.  https://doi.org/10.1016/j.jse.2009.02.011 CrossRefGoogle Scholar
  41. 41.
    Laumonerie P, Reina N, Gutierrez C, Delclaux S, Tibbo ME, Bonnevialle N, Mansat P (2017) Tight-fitting radial head prosthesis: does stem size help prevent painful loosening? Int Orthop.  https://doi.org/10.1007/s00264-017-3644-6
  42. 42.
    Laflamme M, Grenier-Gauthier PP, Leclerc A, Antoniades S, Bedard AM (2017) Retrospective cohort study on radial head replacements comparing results between smooth and porous stem designs. J Shoulder Elb Surg 26(8):1316–1324CrossRefGoogle Scholar
  43. 43.
    Laumonerie P, Reina N, Gutierrez C, Delclaux S, Tibbo ME, Bonnevialle N, Mansat P (2018) Tight-fitting radial head prosthesis: does stem size help prevent painful loosening? Int Orthop 42(1):161–167CrossRefPubMedGoogle Scholar
  44. 44.
    Levy JC, Formaini NT, Kurowicki J (2016) Outcomes and radiographic findings of anatomic press-fit radial head arthroplasty. J Shoulder Elb Surg 25(5):802–809.  https://doi.org/10.1016/j.jse.2015.11.014 CrossRefGoogle Scholar
  45. 45.
    Hackl M, Wegmann K, Koslowsky TC, Zeifang F, Schoierer O, Muller LP (2017) Rare implant-specific complications of the MoPyC radial head prosthesis. J Shoulder Elb Surg 26(5):830–837.  https://doi.org/10.1016/j.jse.2016.11.004 CrossRefGoogle Scholar

Copyright information

© SICOT aisbl 2018

Authors and Affiliations

  1. 1.Department of Trauma and Orthopedic SurgeryBerufsgenossenschaftliche Unfallklinik Frankfurt am MainFrankfurt am MainGermany

Personalised recommendations