Skip to main content
Log in

Coronoid process of the ulna: paleopathologic and anatomic study with imaging correlation. Emphasis on the anteromedial “facet”

  • Scientific Article
  • Published:
Skeletal Radiology Aims and scope Submit manuscript

Abstract

Objective

The purpose of this study was to provide a detailed description of the anatomy of the coronoid process of the ulna and to use magnetic resonance (MR) images and anatomic correlation with cadavers to show the macroscopic configuration of this structure.

Materials and methods

Photography and high-resolution radiography were performed in 26 ulna specimens from the collection of a local museum. MR imaging of the coronoid process of 11 cadaveric elbows was performed. The images were compared with those seen on anatomic sectioning.

Results

The anteromedial rim of the coronoid process of the ulna had a regular surface, without osseous irregularities or facets in 69.2% of the specimens. In 30.8% of the specimens, the anteromedial rim was not regular and a small ridge could be identified. The insertion site of the joint capsule was onto the anterior aspect of the coronoid process, at an average distance of 5.9 mm distal to the tip. The attachment of the anterior band of the ulnar collateral ligament at the sublime tubercle was flush with the articular margin in 63.6% of the specimens. In 36.4% of the specimens, a more distal attachment, with a separation between the undersurface of the ligament and the adjacent tubercle, was seen. The brachialis tendon was attached to the coronoid process at a mean distance of 12.1 mm distal to the tip.

Conclusion

The coronoid process of the ulna is a small osseous structure with a complex anatomy and presents some anatomical variations.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7

Similar content being viewed by others

References

  1. Doornberg J, Ring D. Fracture of the anteromedial facet of the coronoid process. J Bone Joint Surg Am 2006; 88(10): 2216–2224.

    Google Scholar 

  2. Doornberg J, Ring D. Coronoid fracture patterns. J Hand Surg [Am] 2006; 31(1): 45–52.

    Article  Google Scholar 

  3. Sanchez-Satelo J, O’driscoll S, Morrey B. Medial oblique compression fracture of the coronoid process of the ulna. J Shoulder Elbow Surg 2005; 14(1): 60–64.

    Article  Google Scholar 

  4. Doonberg J, Van Duijin J, Ring D. Coronoid fracture height in terrible-triad injuries. J Hand Surg [Am] 2006; 31(5): 794–797.

    Article  Google Scholar 

  5. Matzon JL, Widmer BJ, Draganich LF, Mass DP, Phillips CS. Anatomy of the coronoid process. J Hand Surg [Am] 2006; 31(8): 1272–1278.

    Article  Google Scholar 

  6. Hull JR, Owen JR, Fern SE, Wayne JS, Boardman ND 3rd. Role of the coronoid process in varus osteoarticular stability of the elbow. J Shoulder Elbow Surg 2005; 14(4): 441–446.

    Article  Google Scholar 

  7. Schneeberger A, Sadowski M, Hilaire J. Coronoid process and radial head as posterolateral rotatory stabilizers of the elbow. J Bone Joint Surg Am 2004; 86(5): 975–982.

    Article  Google Scholar 

  8. O’driscoll S, Jupiter J, Cohen M, Ring D, Mckee M. Difficult elbow fractures: pearls and pitfalls. Instr Course Lect 2003; 52: 113–134.

    PubMed  Google Scholar 

  9. Regan W, Morrey B. Fractures of the coronoid process of the ulna. J Bone Joint Surg Am 1989; 71(9): 1348–1354.

    Article  CAS  Google Scholar 

  10. Fowler K, Chung C. Normal MR imaging anatomy of the elbow. Radiol Clin North Am 2006; 44(4): 553–567.

    Article  Google Scholar 

  11. Leonello D, Galley I, Bain G, Carter C. Brachialis muscle anatomy. A study in cadavers. J Bone Joint Surg Am 2007; 89(6): 1293–1297.

    Article  Google Scholar 

  12. Munshi M, Pretterklieber M, Chung C, Haghighi P, Cho J, Trudell D, Resnick D. Anterior bundle of ulnar collateral ligament: evaluation of anatomic relationships by using MR imaging, MR arthrography, and gross anatomic and histologic analysis. Radiology 2004; 231(3): 797–803.

    Article  Google Scholar 

  13. Ring D, Jupiter J, Zilberfarb J. Posterior dislocation of the elbow with fractures of the radial head and coronoid. J Bone Joint Surg Am 2002; 84: 547–551.

    Article  Google Scholar 

  14. Doornberg J, Jong I, Lindenhovius A, Ring D. The anteromedial facet of the coronoid process of the ulna. J Shoulder Elbow Surg 2007; 16(5): 667–670. [Epub ahead of print].

    Article  Google Scholar 

  15. Cage D, Abrams R, Callahan J, Botte M. Soft tissue attachments of the ulnar coronoid process. An anatomic study with radiographic correlation. Clin Orthop Relat Res 1995; 320: 154–158.

    Google Scholar 

  16. Timmerman L, Andrew J. Undersurface tear of the ulnar collateral ligament in baseball players. A newly recognized lesion. Am J Sports Med 1994; 22(1): 33–36. PMID: 8129107.

    Article  CAS  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Marcio Freitas Valle de Lemos Weber.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Weber, M.F.V.d.L., Barbosa, D.M., Belentani, C. et al. Coronoid process of the ulna: paleopathologic and anatomic study with imaging correlation. Emphasis on the anteromedial “facet”. Skeletal Radiol 38, 61–67 (2009). https://doi.org/10.1007/s00256-008-0556-y

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00256-008-0556-y

Keywords

Navigation