Clinical results and radiographic appearance of the Rashkind double umbrella device in patients with occlusion of the ductus arteriosus

  • Published:
Pediatric Radiology Aims and scope Submit manuscript

Abstract

Background. The Rashkind double umbrella device for patent arterial duct occlusion has been used in many patients. Its radiographic appearance has not been sufficiently described. Objective. To present the varying radiographic appearances of the Rashkind double umbrella device on the chest X-ray. Materials and methods. The chest radiographs of 69 patients (median age 60 months; median weight 17 kg), who underwent closure of their patent arterial duct between March 1990 and August 1994, were reviewed. The following parameters were evaluated: 1) the size of the heart (cardio-thoracic ratio) and pulmonary vessels, 2) the position of the device in AP/PA and lateral projections. The results of occlusion of the patent arterial duct were also reviewed. Results. Sixty-two of 69 (90 %) pa- tients had complete occlusion after a follow-up between 2 months and 31/2 years. The cardio-thoracic ratio showed significant reduction at follow-up (P < 0.001). The two different size devices could be well differentiated in the AP and the lateral projection. In 14 patients (20 %) the device was in an asymmetrical position. There was no significant correlation between position of the device and success of occlusion in our material. Conclusion. Complete occlusion of the arterial duct using Rashkind double umbrella devices can be achieved in 90 % of our population. In 20 % the device will have an asymmetrical position. There is no correlation between asymmetrical position of the device in the chest radiograph and residual shunting.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

Author information

Authors and Affiliations

Authors

Additional information

Received: 20 January 1997 Accepted: 23 June 1997

Rights and permissions

Reprints and permissions

About this article

Cite this article

Galal, O., von Sinner, W., Azhari, N. et al. Clinical results and radiographic appearance of the Rashkind double umbrella device in patients with occlusion of the ductus arteriosus. Pediatric Radiology 27, 936–941 (1997). https://doi.org/10.1007/s002470050276

Download citation

  • Issue Date:

  • DOI: https://doi.org/10.1007/s002470050276

Keywords

Navigation