Abstract
Central venous catheters are important in the care for prematurely born children in the neonatal intensive care unit. The purpose of this pictorial essay is to illustrate correct positioning, malpositioning and possible complications of such devices.
Similar content being viewed by others
References
Shaw JCL (1973) Parenteral nutrition in the management of sick low birthweight infants. Pediatr Clin North Am 20:333–358
Cartwright DW (2004) Central venous lines in neonates: a study of 2186 catheters. Arch Dis Child Fetal Neonatal Ed 89:F504–F508. doi:10.1136/adc.2004.049189
Hogan MJ (1999) Neonatal vascular catheters and their complications. Radiol Clin North Am 37:1109–1125
Ramasethu J (2008) Complications of vascular catheters in the neonatal intensive care unit. Clin Perinatol 35:199–222
Stocker M, Berger TM (2006) Arterielle und zentralvenöse Katheter bei Neugeborenen und Säuglingen. Anaesthesist 55:873–882
Vesely TM (2003) Central venous catheter tip position: a continuing controversy. J Vasc Interv Radiol 14:527–553
Ganeshan A, Warakaulle DR, Uberoi R (2007) Central venous access. Cardiovasc Intervent Radiol 30:26–33
Towbin R (2008) The bowed catheter sign: a risk for pericardial tamponade. Pediatr Radiol 38:331–335
Nadroo AM, Glass RB, Lin J et al (2002) Changes in upper extremity position cause migration of peripherally inserted central catheter in neonates. Pediatrics 110:131–136
Connolly B, Amaral J, Walsh S et al (2006) Influence of arm movement on central tip location of peripherally inserted central catheters (PICCs). Pediatr Radiol 36:845–850. doi:10.1007/s00247-006-0172-8
Currarino G (1996) Migration of jugular or subclavian venous catheters into inferior tributaries of the brachiocephalic veins or into azygos vein, with possible complications. Pediatr Radiol 26:439–449
Reece A, Ubhi T, Craig AR et al (2001) Positioning long lines: contrast versus plain radiography. Arch Dis Child Fetal Neonatal Ed 84:F129–F130
Diemer A (1987) Central venous silastic catheters in newborns: localization by sonography and radiology. Pediatr Radiol 17:15–17
Skolnick ML (1994) The role of sonography in the placement and management of jugular and subclavian central venous catheters. AJR 163:291–295
Rand T, Kohlhauser C, Popow C et al (1994) Sonographic detection of internal jugular vein thrombosis after central venous catheterization in the newborn period. Pediatr Radiol 24:577–580
Lanza C, Russo M, Fabrizzi G (2006) Central venous cannulation: are routine chest radiographs necessary after B-mode and colour Doppler sonography check? Pediatr Radiol 36:1252–1256
Nowlen TT, Rosenthal GL, Johnson GL et al (2002) Pericardial effusion and tamponade in infants with central catheters. Pediatrics 110:137–142
Johnson EM, Saltzman DA, Suh G et al (1998) Complications and risks of central venous catheter placement in children. Surgery 124:911–916
Food and Drug Administration Task Force (1998) Precautions necessary with central venous catheters. FDA Drug Bulletin, July, pp 15–16
Yoder D (2001) Cardiac perforation and tamponade: the deadly duo of central venous catheters. Int J Trauma Nurs. 7:108–112. FDA website: http://www.accessdata.fda.gov/scripts/cdrh/cfdocs/psn/transcript.cfm?show=1. Accessed 27 March 2011
Nadroo AM, Lin J, Green RS et al (2001) Death as a complication of peripherally inserted central catheters in neonates. J Pediatr 138:599–601
Nour S, Puntis JW, Stringer MD (1995) Intra-abdominal extravasation complicating parenteral nutrition in infants. Arch Dis Child Fetal Neonatal Ed 72:F207–F208
Baker J, Imong S (2002) A rare complication of neonatal central venous access. Arch Dis Child Fetal Neonatal Ed 86:F61F–62
Lawrenz-Wolf B, Herrmann B (1993) Pericardial tamponade caused by catheter infection in an extremely small premature infant. Monatsschr Kinderheilkd 141:932–935
Cupitt JM (2000) An unusual complication of a central venous catheter in a neonate. Pediatr Anaesth 10:665–668
Rajan V, Waffarn F (1999) Focal neurological manifestations following aberrant central venous catheter placement. J Perinatol 19:447–449
Stehr M, Schuster T, Metzger R et al (2002) Perforation of a central venous catheter into the pelvis of the kidney: a rare complication. Pediatr Radiol 32:323–325
Sridhar S, Thomas N, Kumar ST et al (2005) Neonatal hydrothorax following migration of a central venous catheter. Indian J Pediatr 72:795–796
Koklu E, Poyrazoglu H, Yikilmaz A et al (2008) Subclavian artery pseudoaneursym: a rare and serious complication of central venous catheterization in an infant. Pediatr Radiol 38:220–223
Keeney SE, Richardson CJ (1995) Extravascular extravasation of fluid as a complication of central venous lines in the neonate. J Perinatol 15:284–288
Darling JC, Newell SJ, Mohamdee O et al (2001) Central venous catheter tip in the right atrium: a risk factor for neonatal cardiac tamponade. J Perinatol 21:461–464
Beardsall K, White DK, Pinto EM et al (2003) Pericardial effusion and cardiac tamponade as complications of neonatal long lines: are they really a problem? Arch Dis Child Fetal Neonatal Ed 88:F292–295
Leipala JA, Petaja J, Fellman V (2001) Perforation complications of percutaneous central venous catheters in very low birthweight infants. J Paediatr Child Health 37:168–171
Acknowledgement
We gratefully acknowledge Dr. P. Comoli for her help, wise discussion and suggestions during the preparation of this paper.
Author information
Authors and Affiliations
Corresponding author
Rights and permissions
About this article
Cite this article
Beluffi, G., Perotti, G., Sileo, C. et al. Central venous catheters in premature babies: radiological evaluation, malpositioning and complications. Pediatr Radiol 42, 1000–1008 (2012). https://doi.org/10.1007/s00247-012-2391-5
Received:
Revised:
Accepted:
Published:
Issue Date: