Advertisement

Pediatric Radiology

, Volume 40, Issue 6, pp 869–875 | Cite as

Multidetector CT for congenital heart patients: what a paediatric radiologist should know

  • Jean-François PaulEmail author
  • Adela Rohnean
  • Anne Sigal-Cinqualbre
Review

Abstract

Multidetector CT (MDCT) is increasingly used for imaging congenital heart disease (CHD) patients in addition to echocardiography, due to its ability to provide high quality three-dimensional images, giving a comprehensive evaluation of complex heart malformations. Using 4-slice or 16-slice CT, diagnostic information in CHD patients is limited to extra-cardiac anatomy, mainly the pulmonary arteries, aorta and venous connections. Due to high heart rates in babies however, coronary evaluation and intra-cardiac analysis were not reliable with the first generations of MDCT. Larger detector size with 64-slice CT and faster acquisition time, up to 75 ms for one slice, has progressively improved coronary and intra-cardiac visualization. Because radiation dose is the main concern, especially in children, every attempt to minimize dose whilst preserving image quality is important: the ALARA concept should always be applied in this population. The 80 kVp setting is now well accepted as a standard for more and more radiological teams involved in CT of children. Different acquisition strategies are now possible for childhood coronary imaging, using retrospective or even prospective gating. Using the latest technology, sub-mSv acquisitions are now attainable for scanning a whole thorax, providing a complete analysis of any 3-D cardiac malformation, including coronary artery course visualisation. This review will describe how technological developments have improved image quality with continuous reduction of radiation dose.

Keywords

Congenital Cardiac Multi-detector CT Child 

References

  1. 1.
    Gilkeson RC, Ciancibello L, Zahka K (2003) Pictorial essay. Multidetector CT evaluation of congenital heart disease in pediatric and adult patients. AJR 180:973–980PubMedGoogle Scholar
  2. 2.
    Brenner D, Elliston C, Hall E et al (2001) Estimated risks of radiation-induced fatal cancer from pediatric CT. AJR 176:289–296PubMedGoogle Scholar
  3. 3.
    Tsai IC, Lee T, Chen MC et al (2007) Visualization of neonatal coronary arteries on multidetector row CT: ECG-gated versus non-ECG-gated technique. Pediat Radiol 37:818–825CrossRefPubMedGoogle Scholar
  4. 4.
    Ben Saad M, Rohnean A, Sigal-Cinqualbre A et al (2009) Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease. Pediatr Radiol 39:668–676CrossRefPubMedGoogle Scholar
  5. 5.
    Adler G, Meille L, Rohnean A et al (2009) Robustness of end-systolic reconstructions in coronary dual-source CT angiography for high heart rate patients. Eur Radiol Nov 5 [Epub ahead of print]Google Scholar
  6. 6.
    Vock P (2005) CT dose reduction in children. Eur Radiol 15:2330–2340CrossRefPubMedGoogle Scholar
  7. 7.
    Willis CE, Slovis TL (2005) The ALARA concept in pediatric CR and DR: dose reduction in pediatric radiographic exams-a white paper conference. AJR 184:373–374PubMedGoogle Scholar
  8. 8.
    Paul JF, Abada HT, Sigal-Cinqualbre A (2004) Should low-kilovoltage chest CT protocols be the rule for pediatric patients? AJR 183:1172, author reply 1172PubMedGoogle Scholar
  9. 9.
    Sigal-Cinqualbre AB, Hennequin R, Abada HT et al (2004) Low-kilovoltage multi-detector row chest CT in adults: feasibility and effect on image quality and iodine dose. Radiology 231:169–174CrossRefPubMedGoogle Scholar
  10. 10.
    Westra SJ, Hurteau J, Galindo A et al (1999) Cardiac electron-beam CT in children undergoing surgical repair for pulmonary atresia. Radiology 213:502–512PubMedGoogle Scholar
  11. 11.
    Lee T, Tsai IC, Fu YC et al (2006) Using multidetector-row CT in neonates with complex congenital heart disease to replace diagnostic cardiac catheterization for anatomical investigation: initial experiences in technical and clinical feasibility. Pediatr Radiol 36:1273–1282CrossRefPubMedGoogle Scholar
  12. 12.
    Westra SJ, Hill JA, Alejos JC et al (1999) Three-dimensional helical CT of pulmonary arteries in infants and children with congenital heart disease. AJR 173:109–115PubMedGoogle Scholar
  13. 13.
    Goo HW, Park IS, Ko JK et al (2005) Visibility of the origin and proximal course of coronary arteries on non-ECG-gated heart CT in patients with congenital heart disease. Pediatr Radiol 35:792–798CrossRefPubMedGoogle Scholar
  14. 14.
    Abada HT, Larchez C, Daoud B et al (2006) MDCT of the coronary arteries: feasibility of low-dose CT with ECG-pulsed tube current modulation to reduce radiation dose. AJR 186:S387–S390CrossRefPubMedGoogle Scholar
  15. 15.
    Paul JF, Abada HT (2007) Strategies for reduction of radiation dose in cardiac multislice CT. Eur Radiol 17:2028–2037CrossRefPubMedGoogle Scholar
  16. 16.
    Lambert V, Sigal-Cinqualbre A, Belli E et al (2005) Preoperative and postoperative evaluation of airways compression in pediatric patients with 3-dimensional multislice computed tomographic scanning: effect on surgical management. J Thorac Cardiovasc Surg 129:1111–1118CrossRefPubMedGoogle Scholar

Copyright information

© Springer-Verlag 2010

Authors and Affiliations

  • Jean-François Paul
    • 1
    Email author
  • Adela Rohnean
    • 1
  • Anne Sigal-Cinqualbre
    • 1
  1. 1.Radiology Unit, Marie Lannelongue HospitalPlessis-RobinsonFrance

Personalised recommendations