Abstract
There are many complex cardiac malformations that are characterized by a functionally univentricular physiology. Staged surgical repair according to the Fontan principle separates the systemic and pulmonary circulations by connecting the systemic venous return to the pulmonary arteries. However, long-term follow-up studies demonstrate a gradual deterioration of cardiac function, particularly from the second or third decade. Noninvasive evaluation of the cardiac function is, therefore, important in the follow-up of these patients. The cardiac index (CI) is a reliable hemodynamic parameter and represents an important marker of cardiac function. We compared CI values determined by cardiac MRI (CMRI) with values obtained by noninvasive inert gas rebreathing (IGR; Innocor® system). Sixteen patients (age range: 7.2–32.7 years) with functionally univentricular hearts (UVH) following total cavopulmonary connection (TCPC) were compared with 12 healthy subjects (age range: 8.5–18.6 years). The standard treadmill protocol of the German Society of Pediatric Cardiology was used for exercise testing. CI was determined at rest and at two standardized submaximal exercise levels. In all subjects, CI increased under exercise conditions, but the values were significantly lower in patients with UVH. There was no significant difference between patients with UVH and predominantly right- or left-ventricular morphology. In comparison with CMRI measurements, the CI values obtained by the IGR method tended to be lower, with a mean difference of 1.02 l/min/m2. Noninvasive measurement of CI with the IGR method is feasible at rest and during exercise, and appears to be suited for routine determination of CI in patients with UVH following TCPC.
Similar content being viewed by others
References
Navarro-Aguilar V, Flors L, Calvillo P, Merlos P, Buendía F, Igual B, Melero-Ferrer J, Soriano JR, Leiva-Salinas C (2015) Fontan procedure: imaging of normal post-surgical anatomy and the spectrum of cardiac and extracardiac complications. Clin Radiol 70(3):295–303. https://doi.org/10.1016/j.crad.2014.10.005
Fontan F, Baudet E (1971) Surgical repair of tricuspid atresia. Thorax 26(3):240–248
Gewillig M (2005) The Fontan circulation. Heart 91(6):839–846. https://doi.org/10.1136/hrt.2004.051789
Kaulitz R, Hofbeck M (2005) Current treatment and prognosis in children with functionally univentricular hearts. Arch Dis Child 90(7):757–762. https://doi.org/10.1136/adc.2003.034090
Robbers-Visser D, Kapusta L, van Osch-Gevers L, Strengers JLM, Boersma E, de Rijke YB, Boomsma F, Bogers AJJC, Helbing WA (2009) Clinical outcome 5 to 18 years after the Fontan operation performed on children younger than 5 years. J Thorac Cardiovasc Surg 138(1):89–95. https://doi.org/10.1016/j.jtcvs.2008.12.027
Fontana P, Boutellier U, Toigo M (2010) Non-invasive haemodynamic assessments using Innocor during standard graded exercise tests. Eur J Appl Physiol 108(3):573–580. https://doi.org/10.1007/s00421-009-1252-x
Trinkmann F, Berger M, Doesch C, Sampels M, Papavassiliu T, Grüttner J, Borggrefe M, Kaden JJ, Saur J (2012) Überblick der nicht-invasiven Bestimmung des Herzzeitvolumens—Vergleich neuer Methoden mit dem Goldstandard kardiale Magnetresonanztomografie. Fortschr Röntgenstr 184(02):TNE09. https://doi.org/10.1055/s-0031-1300910
Pennell D (2001) Imaging techniques: cardiovascular magnetic resonance. Heart 85:581–589
Saur J, Fluechter S, Trinkmann F, Papavassiliu T, Schoenberg S, Weissmann J, Haghi D, Borggrefe M, Kaden JJ (2009) Noninvasive determination of cardiac output by the inert-gas-rebreathing method–comparison with cardiovascular magnetic resonance imaging. Cardiology 114(4):247–254. https://doi.org/10.1159/000232407
Agostoni P, Cattadori G (2009) Noninvasive cardiac output measurement: a new tool in heart failure. Cardiology 114(4):244–246. https://doi.org/10.1159/000232406
Agostoni P, Cattadori G, Apostolo A, Contini M, Palermo P, Marenzi G, Wasserman K (2005) Noninvasive measurement of cardiac output during exercise by inert gas rebreathing technique: a new tool for heart failure evaluation. J Am Coll Cardiol 46(9):1779–1781. https://doi.org/10.1016/j.jacc.2005.08.005
Dong L, Wang JA, Jiang CY (2005) Validation of the use of foreign gas rebreathing method for non-invasive determination of cardiac output in heart disease patients. J Zhejiang Univ Sci B 6(12):1157–1162. https://doi.org/10.1631/jzus.2005.B1157
Fontana P, Boutellier U, Toigo M (2009) Reliability of measurements with Innocor during exercise. Int J Sports Med 30(10):747–753. https://doi.org/10.1055/s-0029-1225340
Gabrielsen A, Videbaek R, Schou M, Damgaard M, Kastrup J, Norsk P (2002) Non-invasive measurement of cardiac output in heart failure patients using a new foreign gas rebreathing technique. Clin Sci (Lond) 102(2):247–252
Peyton PJ, Thompson B (2004) Agreement of an inert gas rebreathing device with thermodilution and the direct oxygen Fick method in measurement of pulmonary blood flow. J Clin Monit Comput 18(5–6):373–378
Hauser J, Michel-Behnke I, Zervan K, Pees C (2011) Noninvasive measurement of atrial contribution to the cardiac output in children and adolescents with congenital complete atrioventricular block treated with dual-chamber pacemakers. Am J Cardiol 107(1):92–95. https://doi.org/10.1016/j.amjcard.2010.08.050
Wiegand G, Binder W, Ulmer H, Kaulitz R, Riethmueller J, Hofbeck M (2012) Noninvasive cardiac output measurement at rest and during exercise in pediatric patients after interventional or surgical atrial septal defect closure. Pediatr Cardiol 33(7):1109–1114. https://doi.org/10.1007/s00246-012-0239-2
Wiegand G, Kerst G, Baden W, Hofbeck M (2010) Noninvasive cardiac output determination for children by the inert gas-rebreathing method. Pediatr Cardiol 31(8):1214–1218. https://doi.org/10.1007/s00246-010-9806-6
Dubowy KO, Baden W, Bernitzki S, Peters B (2008) A practical and transferable new protocol for treadmill testing of children and adults. Cardiol Young 18(6):615–623. https://doi.org/10.1017/s1047951108003181
Lang CC, Karlin P, Haythe J, Tsao L, Mancini DM (2007) Ease of noninvasive measurement of cardiac output coupled with peak VO2 determination at rest and during exercise in patients with heart failure. Am J Cardiol 99(3):404–405. https://doi.org/10.1016/j.amjcard.2006.08.047
Hager A, Hess J (2005) Comparison of health related quality of life with cardiopulmonary exercise testing in adolescents and adults with congenital heart disease. Heart 91(4):517–520. https://doi.org/10.1136/hrt.2003.032722
Ovroutski S, Nordmeyer S, Miera O, Ewert P, Klimes K, Kuhne T, Berger F (2012) Caval flow reflects Fontan hemodynamics: quantification by magnetic resonance imaging. Clin Res Cardiol 101(2):133–138. https://doi.org/10.1007/s00392-011-0374-4
Bossers SSM, Kapusta L, Kuipers IM, van Iperen G, Moelker A, Kroft LJM, Romeih S, de Rijke Y, ten Harkel ADJ, Helbing WA (2015) Ventricular function and cardiac reserve in contemporary Fontan patients. Int J Cardiol 196(0):73–80. https://doi.org/10.1016/j.ijcard.2015.05.181
Whitehead KK, Gillespie MJ, Harris MA, Fogel MA, Rome JJ (2009) Noninvasive quantification of systemic-to-pulmonary collateral flow: a major source of inefficiency in patients with superior cavopulmonary connections. Circ Cardiovasc Imag 2(5):405–411. https://doi.org/10.1161/circimaging.108.832113
Bossers SS, Cibis M, Gijsen FJ, Schokking M, Strengers JL, Verhaart RF, Moelker A, Wentzel JJ, Helbing WA (2014) Computational fluid dynamics in Fontan patients to evaluate power loss during simulated exercise. Heart 100(9):696–701. https://doi.org/10.1136/heartjnl-2013-304969
Ohuchi H, Hiraumi Y, Tasato H, Kuwahara A, Chado H, Toyohara K, Arakaki Y, Yagihara T, Kamiya T (1999) Comparison of the right and left ventricle as a systemic ventricle during exercise in patients with congenital heart disease. Am Heart J 137(6):1185–1194
Ohuchi H, Yasuda K, Hasegawa S, Miyazaki A, Takamuro M, Yamada O, Ono Y, Uemura H, Yagihara T, Echigo S (2001) Influence of ventricular morphology on aerobic exercise capacity in patients after the Fontan operation. J Am Coll Cardiol 37(7):1967–1974. https://doi.org/10.1016/S0735-1097(01)01266-9
Giardini A, Hager A, Pace Napoleone C, Picchio FM (2008) Natural history of exercise capacity after the Fontan operation: a longitudinal study. Ann Thorac Surg 85(3):818–821. https://doi.org/10.1016/j.athoracsur.2007.11.009
Saur J, Trinkmann F, Doesch C, Scherhag A, Brade J, Schoenberg SO, Borggrefe M, Kaden JJ, Papavassiliu T (2010) The impact of pulmonary disease on noninvasive measurement of cardiac output by the inert gas rebreathing method. Lung 188(5):433–440. https://doi.org/10.1007/s00408-010-9257-0
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Ethical Approval
The study protocol was approved by the local ethics committee of the University Hospital Tuebingen.
Rights and permissions
About this article
Cite this article
Kuhn, M., Hornung, A., Ulmer, H. et al. Comparative Noninvasive Measurement of Cardiac Output Based on the Inert Gas Rebreathing Method (Innocor®) and MRI in Patients with Univentricular Hearts. Pediatr Cardiol 39, 810–817 (2018). https://doi.org/10.1007/s00246-018-1824-9
Received:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00246-018-1824-9