Abstract
Three approaches based on continuous flow methodology are assessed for the purpose of extending the dynamic range of flame atomic absorption spectrometry. The determination of several elements in infant liquid and powdered milk and water samples is used to check the performances of the manifolds. Two of the systems are fully computer-controlled and permit a calibration graph to be obtained by using a single standard solution. The results confirm that continuous flow methodology is a reliable alternative to the time-consuming common dilution procedures based on glassware. Since the systems are versatile and permit a wide range of degrees of dilution to be obtained, they can be easily adapted for the automated or semi-automated analysis of other liquid samples which are too concentrated to be aspirated directly into the atomic absorption spectrometer.
Similar content being viewed by others
References
Fang Z (1989) In: Burguera JL (ed) Flow injection atomic spectroscopy, Chapter 4. Dekker, New York
Tyson JF (1988) Fresenius Z Anal Chem 329: 663–667
Tyson JF (1991) Spectrochim Acta Rev 14: 169–233
Trojanowicz M, Olbrych-Sleszyńska E (1992) Chem Anal 37: 111–138
Beinrohr E, Csémi P, Tyson JF (1991) J Anal At Spectrom 6: 307–311
Carbonell V, Sanz A, Salvador A, de la Guardia M (1991) J Anal At Spectrom 6: 233–238
Israel Y, Barnes RM (1991) Analyst 116: 489–495
Sperling M, Fang Z, Welz B (1991) Anal Chem 63: 151–159
Fang Z, Sperling M, Welz B (1992) Anal Chim Acta 269: 9–19
López García I, Arroyo Cortéz J, Hernández Córdoba M (1992) J Anal At Spectrom 7: 1291–1294
Fang Z, Welz B, Sperling M (1993) Anal Chem 65: 1682–1688
López García I, Viñas P, Hernández Córdoba M (1994) J Anal At Spectrom 9: 553–561
López García I, Viñas P, Hernández Córdoba M (1994) J Anal At Spectrom 9: 1167–1172
Xu S, Fang Z (1994) Microchem J 50: 145–150
López García I, Viñas P, Campillo N, Hernández Córdoba M (1995) Anal Chim Acta 308: 85–95
Miller JC, Miller JN (1993) Statistics for analytical chemistry, 3rd edn. Horwood, Chichester
Viñas P, Campillo N, López García I, Hernández Córdoba M (1993) Anal Chim Acta 283: 393–400
Bautista MA, Pérez Sirvent C, López García I, Hernández Córdoba M (1994) Fresenius J Anal Chem 350: 359–364
López García I, Arroyo Cortéz J, Hernández Córdoba M (1993) Talanta 40: 1677–1685
Sherwood RA, Rocks BF, Riley C (1985) Analyst 110: 493–496
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
García, I.L., Viñas, P., Campillo, N. et al. Extending the dynamic range of flame atomic absorption spectrometry: a comparison of procedures for the determination of several elements in milk and mineral waters using on-line dilution. Fresenius J Anal Chem 355, 57–64 (1996). https://doi.org/10.1007/s0021663550057
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/s0021663550057