Abstract
In this work, a simple, sensitive, and selective method for the determination of silver ions (Ag+) was proposed on the basis of the enhancement of Ag+ on the electrogenerated chemiluminescence (ECL) of peroxydisulfate (S2O8 2−), which can be attributed to the obvious electrocatalytic reduction of S2O8 2− by Ag+, giving rise to more abundant sulfate radical anion (SO4 •−). Under optimal conditions, a linear range from 4 to 500 nM (R = 0.997) with a detection limit of 2.5 nM (S/N = 3) was achieved for the detection of Ag+. The Ag+/S2O8 2− ECL system could not only provide an assay protocol for the determination of Ag+ but also offer an effective way to enhance the ECL of S2O8 2−, which may act as a promising platform for the detection of other species such as 4-chlorophenol.
Similar content being viewed by others
References
Richter MM. Chem Rev. 2004;104:3003–36.
Hu LZ, Xu GB. Chem Soc Rev. 2010;39:3275–304.
Wu P, Hou XD, Xu JJ, Chen HY. Chem Rev. 2014;114:11027–59.
White HS, Bard AJ. J Am Chem Soc. 1982;104:6891–5.
Wang H, Xu G, Dong S. Microchem J. 2002;72:43–8.
Xu G, Dong S. Anal Chim Acta. 2000;412:235–40.
Jie GF, Yuan JX. Anal Chem. 2012;84:2811–7.
Yang SL, Liang JS, Luo SL, Liu CB, Tang YH. Anal Chem. 2013;85:7720–5.
Reshetnyak OV, Kovalchuk EP. Electrochim Acta. 1998;32:354–8.
Yao W, Wang L, Wang HY, Zhang XL. Electrochim Acta. 2008;54:733–7.
Park J, Lee S, Jang K, Na S. Biosens Bioelectron. 2014;60:299–304.
Li XM, Sun L, Ding TR. Biosens Bioelectron. 2011;26:3570–6.
Firooz A, Ensafi A, Kazemifard N, Khalifeh R. Sens Actuators B. 2013;176:598–604.
Dadfarnia S, Shabani A, Gohari M. Talanta. 2004;64:682–7.
Krachler M, Mohl C, Emons H, Shotyk W. Spectrochim Acta B. 2002;57:1277–89.
Wygladacz K, Radu A, Xu C, Qin Y, Bakker E. Anal Chem. 2005;77:4706–12.
Chen LC, Zeng XT, Si P, Chen YM, Chi YW, Kim D, et al. Anal Chem. 2014;86:4188–95.
Yamashita K, Nishida S, Harima Y, Segawa A. Anal Chem. 1991;63:872–6.
Shen LM, Chen ML, Hu LL, Chen XW, Wang JH. Langmuir. 2013;29:16135–40.
Khantaw T, Boonmee C, Tuntulani T, Ngeontae W. Talanta. 2013;115:849–56.
Yue Y, Liu TY, Li HW, Liu ZY, Wu YQ. Nanoscale. 2012;4:2251–4.
Yang M, Wang Y, Wang HY. Electrochim Acta. 2015;169:7–12.
Acknowledgments
This work is supported by the National Natural Science Foundation of China (No. 21345004), Foundation for Innovation Team of Bioanalytical Chemistry, and the Project Sponsored by the Scientific Research Foundation for the Returned Overseas Chinese Scholars, State Education Ministry.
Author information
Authors and Affiliations
Corresponding author
Ethics declarations
Conflict of interest
The authors declare that they have no conflict of interest.
Additional information
Published in the topical collection Analytical Electrochemiluminescence with guest editors Hua Cui, Francesco Paolucci, Neso Sojic, and Guobao Xu.
Rights and permissions
About this article
Cite this article
Wang, H., Fan, X. & Wang, Y. Determination of silver ions based on the electrogenerated chemiluminescence of silver ions/peroxydisulfate. Anal Bioanal Chem 408, 7113–7119 (2016). https://doi.org/10.1007/s00216-016-9640-7
Received:
Revised:
Accepted:
Published:
Issue Date:
DOI: https://doi.org/10.1007/s00216-016-9640-7