Skip to main content
Log in

Safe pleural contraction employing a new tip for electrosurgical units

An ex vivo experiment

  • Original Article
  • Published:
The Japanese Journal of Thoracic and Cardiovascular Surgery Aims and scope Submit manuscript

Abstract

Background: Certain pulmonary lesions are treated by lung tissue contraction induced by heat administered by laser or electrosurgical unit (ES). ESs are comparatively less expensive, less complicated and more ubiquitous than a lasers but with their conventional tip carries the a risk of damaging the pleura. We developed a large ball tip (M-tip) for ES and evaluated its effect on the pleura in comparison with that of Nd: YAG laser in ex vivo lung.Method: We employed lobes obtained through surgical resection. Using the Nd:YAG laser, the lung was irradiated for 2 seconds at levels of 5, 10 and 20 watts (10,20 and 40 Joules). Using the M-tip ES, the pleura received treatment at levels of 10, 20 and 40 watts for 2 seconds (20, 40 and 80 Joules) in spray coagulation mode. Upon completion of these procedures, 144 tissue specimens obtained from 24 lobes were examined under light microscopy.Results: Upon the application of Nd:YAG at 20 Joules, 22 (92%) of 24 visceral pleura demonstrated amorphous degeneration. With the application of ES at 40 Joules watts, 24 (100%) samples examined demonstrated amorphous degeneration (P=0.47). Of the samples where pleural destruction was evident (Nd: YAG; 40 Joules, ES; 80 Joules), an accompanying air leak pattern (pleural destruction associated with slight parenchymal contraction) was observed in 5 (21%) of the samples treated with Nd:YAG and in 10 (42%) of those treated with the M-tip ES (p=0.12).Conclusion: The M-tip ES induced proper contraction of the pleura with relatively little destructive damage to the pleura at 40 Joules. Accordingly, it may be possible to induce pleural contraction using this new device with the same degree of safely that the Nd:YAG laser provides.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Wakabayashi A. Thoracoscopic ablation of blebs in the treatment of recurrent or persistent spontaneous pneumothorax. Ann Thorac Surg 1989; 48: 651–3.

    Article  PubMed  CAS  Google Scholar 

  2. Wakabayashi A, Brenner M, Wilson AF, Tadir Y, Berns M. Thoracoscopic treatment of spontaneous pneumothorax using carbon dioxide laser. Ann Thorac Surg 1990; 50: 786–90.

    PubMed  CAS  Google Scholar 

  3. Lewis RJ, Caccavale RJ, Sisler GE. VATS-argon beam coagulator treatment of diffuse end-stage bilateral bullous disease of the lung. Ann Thorac Surg 1993; 55: 1394–9.

    Article  PubMed  CAS  Google Scholar 

  4. Sharpe DA, Dixon C, Moghissi K. Thoracoscopic use of laser in intractable pneumothorax. Eur J Cardio-thorac Surg 1994; 8: 34–6.

    Article  CAS  Google Scholar 

  5. Sawabata N, Nezu K, Tojo T, Kitamura S. In vitro comparison between Argon Beam Coagulator and Nd:YAG laser in lung contraction therapy. Ann Thorac Surg 1996; 62: 1485–8.

    Article  PubMed  CAS  Google Scholar 

  6. Sawabata N, Nezu K, Tojo T, and Kitamura S. In vitro study of ablated lung tissue in Nd:YAG laser irradiation. Ann Thorac Surg 1996; 61: 164–9.

    Article  PubMed  CAS  Google Scholar 

  7. LoCicero J, Fredriksen JW, Hartz RS. Pulmonary procedures assisted by optosurgical and electrosurgical devices: comparison of damage potential. Lasers in Surg and Med. 1987; 7: 263–72.

    Article  Google Scholar 

  8. Moghissi K, Neville DE. Effect of the non-contact mode of YAG laser on pulmonary tissues and its comparison with electrodiathermy: an anatomo-pathological study. Lasers in Med Science. 1988; 17: 17–23.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Sawabata, N., Iuchi, K., Ikeda, M. et al. Safe pleural contraction employing a new tip for electrosurgical units. Jpn J Thorac Caridovasc Surg 46, 1221–1225 (1998). https://doi.org/10.1007/BF03217906

Download citation

  • Received:

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF03217906

Index words

Navigation