A Monte Carlo model of an industrial gauge for radiation protection purposes

Scientific Note


The Mahlo Gravimat densitometers/gauges located at the Feltex carpet factory in Christchurch, New Zealand, contain the radionuclide strontium-90 (Sr-90). Accurate dose/dose rate estimation is always an important concern from a radiation protection point of view. The EGSnrc/BEAMnrc Monte Carlo code was used to create a model of one gauge to determination of the radiation dose distributions and dose rates in air from the Sr-90 source within the gauge. The model was then modified to include a Perspex shield on the surface of the gauge as a possible method of lowering the radiation levels. With this addition, the model predicted an overall reduction in dose rates of 30%. Although no experimental benchmarking was able to be performed due to simplifications in the model and the lack of reliable experimental data, we believe that Monte Carlo methods could be a valuable addition in the design process of any devices, industrial or otherwise, that contain or use radioactive materials. Furthermore, such methods may aide or guide any investigations undertaken as part of radiation protection surveys.

Key words

Monte Carlo radiation protection manufacturing industry dose rate 


  1. 1.
    CRP,Publication 60: 1990 Recommendations of the International Commission on Radiological Protection, 1990.Google Scholar
  2. 2.
    NRL,C19: Code of safe practice for the use of industrial gauges containing sealed radioactive sources., National Radiation Laboratory, New Zealand 2005.Google Scholar
  3. 3.
    Mahlo, Saal/Donau, GermanyGoogle Scholar
  4. 4.
    Rogers, D.W.O., Faddegon, B.A., Ding, G.X., Ma, C.-M. and We, J., BEAM:A Monte Carlo code to simulate radiotherapy treatment units, Medical Physics, 22:503–524, 1995.CrossRefPubMedGoogle Scholar
  5. 5.
    Packer, K.,Dose rate and surface contamination measurements of density gauges at Feltex, 2006. Private communication.Google Scholar
  6. 6.
    Kawrakow, I.,Accurate condensed history Monte Carlo simulation of electron transport. I. EGSnrc, the new EGS4 version, Medical Physics, 27:485–493, 2000.CrossRefPubMedGoogle Scholar
  7. 7.
    Nelson, W., Hirayama, H. and Rogers, D.W.O.,The EGS4 Code System, Report SLAC-265, 1985.Google Scholar
  8. 8.
    Nicholl, R.,Personal communication with Reece Nicholl -Project and Technical Manager, Feltex New Zealand Woven Plant, 2006.Google Scholar
  9. 9.
    Rogers, D.W.O., Walters, B. and Kawrakow, I.,BEAMnrc Users manual, 2005.Google Scholar
  10. 10.
    Ma, C.M. and Rogers, D.W.O.,BEAMDP Users Manual, 2005.Google Scholar
  11. 11.
    Kahn, F.M.,Intravascular brachytherapy. In: T. Boyce, The Physics of Radiation Therapy, 3rd ed., Lippincott Williams & Wilkins, Philadelphia, 548–560, 2003.Google Scholar
  12. 12.
    Ma, C.M. and Rogers, D.W.O.,BEAMDP as a General-Purpose Utility. NRC Report PIRS 509e(rev A), 2004.Google Scholar
  13. 13.
    Kahn, F.M.,Measurement of absorbed dose. In: T. Boyce,The Physics of Radiation Therapy, 3rd ed., Lippencott Williams & Wilkins, Philadelphia, 106–156, 2003.Google Scholar
  14. 14.
    Kocher, D.C.,Dose rate conversion factors for external exposure to photon and electrons, Health Physics, 45:665–686, 1983.CrossRefPubMedGoogle Scholar
  15. 15.
    Johns, H.E. and Cunningham, J.R.,The Physics of Radiology, 4th ed., Charles C Thomas, Springfield, Illinois, 1983.Google Scholar

Copyright information

© Australasian College of Physical Scientists and Engineers in Medicine 2008

Authors and Affiliations

  • R. McGurk
    • 1
  • J. Turner
    • 1
    • 2
  • H. M. Deloar
    • 2
  • K. Packer
    • 2
  1. 1.Department of Physics and AstronomyUniversity of CanterburyChristchurchNew Zealand
  2. 2.Medical Physics and BioengineeringChristchurch Public HospitalChristchurchNew Zealand