Abstract
We determined how often and for how long usable pressure waveforms were unavailable from a radial intraarterial pressure cannula during anesthesia and surgery in 41 patients. During cardiac surgery with a continuous flush system, usable arterial pressure was unavailable 8.7% of the time. It was unavailable 9.1% of the time during noncardiac surgical procedures with a continuous flush system, and 14.7% of the time in systems without continuous flush. Thus, the use of a continuous flush device improves intraarterial pressure availability. Artifact is the principal contributor to unavailability, followed by flushing and blood sampling. With rare exceptions the use of a Riva-Rocci cuff for occasional return-to-flow maneuvers on the same arm as the intraarterial cannula reduces intraarterial pressure availability only slightly, certainly not enough to detract from its usefulness in providing an estimation of systolic pressure during intraarterial pressure monitoring.
Similar content being viewed by others
References
Prys-Roberts C: Invasive monitoring of the circulation. In: Saidman LJ, Smith NT, eds. Monitoring in anesthesia. Boston: Butterworth, 1984:83–93
Smith NT, Wesseling KH, de Wit B: Evaluation of two prototype devices producing noninvasive, pulsatile, calibrated blood pressure measurement from a finger. J Clin Monit 1985; 1:17–29
Penaz J. Voigt A, Teichmann W: Beitrag zur fortlaufenden indirekten Blutdruckmessung. Zschr Inn Med 1976; 31:1030–1033
Hellige, G: Ventrikeldruckmessung mit konventionellen Kathetermanometersystemen. Teil 1. Basic Res Cardiol 1976; 71:319–336
Hellige, G: Ventrikeldruckmessung mit konventionellen Kathetermanometersystemen. Teil II. Basic Res Cardiol 1976; 71:389–406
Bruner JMR: Handbook of blood pressure monitoring. Littleton, MA: PSG, 1978
Bruner JMR, Krenis LR, Kunsman JM, Sherman AP: Comparison of direct and indirect methods of measuring arterial blood pressure, part I. Med Instrum 1981; 15:11–21
Bruner JMR, Krenis LR, Kunsman JM, Sherman AP: Comparison ot direct and indirect methods of measuring arterial blood pressure, part II. Med Instrum 1981; 15:97–101
Bruner JMR, Krenis LR, Kunsman JM, Sherman AP: Comparison ot direct and indirect methods of measuring arterial blood pressure, part III. Med Instrum 1981; 14:182–188
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Wesseling, K.H., Smith, N.T. Availability of intraarterial pressure waveforms from catheter-manometer systems during surgery. J Clin Monitor Comput 1, 11–16 (1985). https://doi.org/10.1007/BF02832684
Received:
Revised:
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02832684