Availability of intraarterial pressure waveforms from catheter-manometer systems during surgery

  • Karel H. Wesseling
  • N. Ty Smith
Article

Abstract

We determined how often and for how long usable pressure waveforms were unavailable from a radial intraarterial pressure cannula during anesthesia and surgery in 41 patients. During cardiac surgery with a continuous flush system, usable arterial pressure was unavailable 8.7% of the time. It was unavailable 9.1% of the time during noncardiac surgical procedures with a continuous flush system, and 14.7% of the time in systems without continuous flush. Thus, the use of a continuous flush device improves intraarterial pressure availability. Artifact is the principal contributor to unavailability, followed by flushing and blood sampling. With rare exceptions the use of a Riva-Rocci cuff for occasional return-to-flow maneuvers on the same arm as the intraarterial cannula reduces intraarterial pressure availability only slightly, certainly not enough to detract from its usefulness in providing an estimation of systolic pressure during intraarterial pressure monitoring.

Keywords

Monitoring Blood pressure Artifact Arterial pressure 

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

References

  1. 1.
    Prys-Roberts C: Invasive monitoring of the circulation. In: Saidman LJ, Smith NT, eds. Monitoring in anesthesia. Boston: Butterworth, 1984:83–93Google Scholar
  2. 2.
    Smith NT, Wesseling KH, de Wit B: Evaluation of two prototype devices producing noninvasive, pulsatile, calibrated blood pressure measurement from a finger. J Clin Monit 1985; 1:17–29PubMedCrossRefGoogle Scholar
  3. 3.
    Penaz J. Voigt A, Teichmann W: Beitrag zur fortlaufenden indirekten Blutdruckmessung. Zschr Inn Med 1976; 31:1030–1033Google Scholar
  4. 4.
    Hellige, G: Ventrikeldruckmessung mit konventionellen Kathetermanometersystemen. Teil 1. Basic Res Cardiol 1976; 71:319–336PubMedCrossRefGoogle Scholar
  5. 5.
    Hellige, G: Ventrikeldruckmessung mit konventionellen Kathetermanometersystemen. Teil II. Basic Res Cardiol 1976; 71:389–406PubMedCrossRefGoogle Scholar
  6. 6.
    Bruner JMR: Handbook of blood pressure monitoring. Littleton, MA: PSG, 1978Google Scholar
  7. 7.
    Bruner JMR, Krenis LR, Kunsman JM, Sherman AP: Comparison of direct and indirect methods of measuring arterial blood pressure, part I. Med Instrum 1981; 15:11–21PubMedGoogle Scholar
  8. 8.
    Bruner JMR, Krenis LR, Kunsman JM, Sherman AP: Comparison ot direct and indirect methods of measuring arterial blood pressure, part II. Med Instrum 1981; 15:97–101PubMedGoogle Scholar
  9. 9.
    Bruner JMR, Krenis LR, Kunsman JM, Sherman AP: Comparison ot direct and indirect methods of measuring arterial blood pressure, part III. Med Instrum 1981; 14:182–188Google Scholar

Copyright information

© Little, Brown and Company, Inc. 1985

Authors and Affiliations

  • Karel H. Wesseling
    • 1
  • N. Ty Smith
    • 2
  1. 1.Cardiovascular Physics GroupDivision for Technical Scientific Services TNOUtrechtThe Netherlands
  2. 2.Department of AnesthesiologyUniversity of California, San Diego, Veterans Administration Medical CenterSan DiegoCA

Personalised recommendations