Abstract
The effect of an overloading test on the remaining service life of a metallic structure exposed to corrosion is discussed. Conditions of destruction during such tests have been determined. The reduction in the service life as a result of such tests is quite considerable, but, if an overloading test does not lead to destruction, the reduction in the service life is small.
Similar content being viewed by others
References
Petrov, V.A., On Overloading Tests,Defektoskopiya, 1997, no. 3, pp. 92–98.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Petrov, G.V. Reduction in the service life due to an overload test of a metallic structure operated under corrosive conditions. Russ J Nondestruct Test 36, 227–230 (2000). https://doi.org/10.1007/BF02759334