Abstract
A failure analysis was conducted on a flow-sensing device that had cracked while in service. The polysulfone sensor body cracked radially, adjacent to a molded-in steel insert. This article describes the investigative methods used to conduct the failure analysis. The techniques utilized included scanning electron microscopy, Fourier transform infrared spectroscopy, differential scanning calorimetry, thermomechanical analysis, and melt flow rate determination. It was the conclusion of the investigation that the part failed via brittle fracture, with evidence also indicating low cycle fatigue associated with cyclic temperature changes from normal service. The design of the part and the material selection were significant contributing factors because of stresses induced during molding, physical aging of the amorphous polysulfone resin, and the substantial differential in coefficients of thermal expansion between the polysulfone and the mating steel insert.
Similar content being viewed by others
References
James E. Harris:Handbook of Plastic Materials and Technology, Irvin I. Rubin, ed., John Wiley & Sons, Inc., New York, NY, 1990, pp. 487–491.
Plastics Engineering Handbook of the Society of the Plastics Industry, Inc., 5th ed., Michael L. Berins, ed., Chapman & Hall, New York, NY, 1991, p. 752.
Julie P. Harmon and Charles L. Beatty:Engineered Materials Handbook, vol. 2, ASM International, Metals Park, OH, 1988, p. 751.
James E. Harris:Handbook of Plastic Materials and Technology, Irvin I. Rubin, ed., John Wiley & Sons, Inc., New York, NY, 1990, p. 488.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Jansen, J.A. Failure analysis of a polysulfone flow sensor body — A case study. Practical Failure Analysis 1, 55–58 (2001). https://doi.org/10.1007/BF02715163
Received:
Revised:
Issue Date:
DOI: https://doi.org/10.1007/BF02715163