To determine whether large and repeatable c-waves can be recorded from rabbits with equipment already in use in clinical electroretinographic laboratories, the Burian-Allen electrode, connected bipolarly or monopolarly, was used to record electroretinograms from pigmented rabbits. The Jet electrode was also used. The c-waves elicited by long-duration (4-second) stimuli were compared to those elicited by stroboscopic stimuli. In addition, the c-waves recorded with direct-coupled amplification were compared to those recorded with condenser-coupled amplification (one-half-amplitude bandpass=0.1 Hz). The b-wave amplitude was not altered by the amplifier coupling or by the two stimulus durations. The largest c-waves were elicited by 4-second-duration stimuli and recorded with direct-coupled amplification. Although the c-wave amplitude was reduced by stroboscopic stimuli and by condenser coupling, large and repeatable c-waves were elicited by stroboscopic stimuli and recorded with condenser-coupled amplification. A comparison of stimulus duration and amplifier coupling showed that the stimulus duration was more important in recording large-amplitude c-waves. Similar results were obtained with the Jet electrode. We conclude that repeatable and large c-waves can be elicited by a stroboscopic stimuli and can be recorded with condenser-coupled amplification with good low-frequency response from rabbits.
Similar content being viewed by others
References
Steinberg RH, Linsenmeier RA, Griff ER. Retinal pigment epithelial cell contributions to the electroretinogram and electrooculogram. Prog Retinal Res 1999; 4: 33–66.
Oakley B II, Green DG. Correlation of light-induced changes in retinal extracellular potassium concentration with c-wave of electroretinogram. J Neurophysiol 1976; 39: 1117–33.
Nilsson SEG, Anderson BE, Corneal DC. Recordings of slow ocular potential changes such as the ERG c-wave and the light peak in clinical work. Doc Ophthalmol 1988; 68: 313–25.
Marmor MF, Arden GB, Nilsson SEG, Zrenner E. Standard for clinical electroretinography. Doc Ophthalmol 1989; 73: 303–11.
Hock PA, Marmor MF. Variability of the human c-wave. Doc Ophthalmol 1983; 37: 67–72.
Skoogs K-O, Nilsson SEG. The c-wave of the human dc registered ERG, I: a quantitative study of the relationship between c-wave amplitude and stimulus intensity. Acta Ophthamol 1974; 53: 759–73.
Steinberg RH, Oakley B II, Niemeyer G. Light-evoked changes in [K+]0 in retina of intact cat eye. J Neurophysiol 1980; 44: 897–921.
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Hamasaki, D.I., Korabathina, K., Patel, S.R. et al. The c-wave of the electroretinogram recorded under clinical conditions from rabbits. Doc Ophthalmol 94, 365–381 (1997). https://doi.org/10.1007/BF02580861
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02580861