Skip to main content
Log in

A study about the environmental impact of a large particulate matter source by means of a sampling station interactive with the environment

  • Published:
Il Nuovo Cimento C

Summary

The contribution of the particulate matter relapsed from a large oil-fired power plant into the surrounding environment was investigated by means of an automated sampling station interactive with the environment. This station performs real-time measurements of some meteorological parameters and of the concentrations of some gaseous pollutants, thus carrying out aerosol samplings only in situations of environmental interest such as fumigation or blank conditions. Elemental composition of the fractionated particulate matter and morphological observations on single particles were obtained using PIXE (particle-induced X-ray emission) and SEM (scanning electron microscopy) techniques.

Riassunto

Il contributo all’inquinamento dovuto all’emissione di materiale particolato da una centrale termoelettrica ad olio combustibile è stato studiato utilizzando una stazione di prelievo funzionante in modo interattivo con l’ambiente. Questa stazione è in grado di effettuare prelievi di aerosol atmosferico pilotati da prefissati valori di parametri ambientali, sia di tipo meteorologico che di concentrazione di alcuni inquinanti gassosi, che permettono di discriminare situazioni di ricaduta del pennacchio da situazioni tipicamente di fondo. La composizione elementare del particolato, frazionato nelle diverse classi dimensionali, è stata ottenuta mediante la tecnica multielementare PIXE (emissione di raggi X indotte da particelle), mentre osservazioni morfologiche sulle particelle campionate sono state effettuate mediante SEM (microscopia elettronica a scansione).

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. P. Bacci, A. Longhetto G. Marcazzan, A. Piano, R. Prodi, C. Sabbioni andA. Ventura:J. Aerosol Sci.,14, 222 (1983).

    Article  Google Scholar 

  2. A. Caruso, A. Gray, G. M. Marcazzan andA. Zinni:Inquinamento,11, 51 (1983).

    Google Scholar 

  3. R. I. Mitchell andJ. M. Pilcher:Ind. Eng. Chem.,51, 1039 (1959).

    Article  Google Scholar 

  4. B. Y. H. Liu andG. A. Kuhlmey:X-ray Fluorescence Analysis of Environmental Samples, edited byT. G. Dzubay (Ann. Arbor, 1977), p. 107.

  5. P. Bacci, M. Dal Monte, A. Longhetto, A. Piano, F. Prodi, P. Redaelli, C. Sabbioni andA. Ventura:J. Aerosol Sci.,14, 557 (1983).

    Article  Google Scholar 

  6. E. Caruso, G. M. Braga Marcazzan andP. Redaelli:Nucl. Instrum. Methods,174, 195 (1980).

    Article  Google Scholar 

  7. W. M. Henry andT. H. Knapp:Environ. Sci. Technol.,14, 4, 450 (1980).

    Article  Google Scholar 

  8. R. Tartarelli, P. Davini, F. Morelli andP. Corsi:Atmos. Environ.,12, 289 (1978).

    Article  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Balduzzi, P., Ventura, A., Braga Marcazzan, G.M. et al. A study about the environmental impact of a large particulate matter source by means of a sampling station interactive with the environment. Il Nuovo Cimento C 9, 89–94 (1986). https://doi.org/10.1007/BF02508054

Download citation

  • Received:

  • Revised:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02508054

PACS. 92.60

Navigation