Skip to main content
Log in

Tomographic measurement of temperature change in phantoms of the human body by chirp radar-type microwave computed tomography

  • Medical Physics and Imaging
  • Published:
Medical & Biological Engineering & Computing Aims and scope Submit manuscript

Abstract

The chirp radar-type microwave computed tomograph (CT) measures the temperature change in a human body noninvasively. The paper examines its feasibility. A chirp pulse signal between 1 and 2 GHz is radiated from the transmitting antenna to the phantom. The transmitted waves are detected by the receiving antenna, which is place on the opposite side of the object, and the beat signal between the incident wave and the transmitted wave is produced by the mixer. By spectral analysis of the beat signal, only those signals transmitted on the straight line between the transmitting antenna and the receiving antenna are discriminated from multipath signals. The microwave tomogram can therefore be reconstructed easily using the conventional algorithms for an X-ray CT image. The microwave CT can use the chirp signal to remove the influence of multipath signals caused by diffraction and reflection. The imaging of dielectric materials with complicated structures is thus possible. The experimental results using phantoms show that the spatial resolution of this microwave CT is about 10 mm and that a two-dimensional distribution of temperature change can be measured.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  • BOLOMEY, J. Ch., JOFRE, L. and PERONNET, G. (1983) On the possible use of microwave-active imaging for remote thermal sensing. IEEE Trans., MTT-31, 777–781.

    Google Scholar 

  • JACOBI, J. H. and LARSEN, L. E. (1986) Linear FM pulse compression radar techniques applied to biological imaging. In Medical applications of microwave imaging. LARSEN, L. E. and JACOBI J. H. (Eds.) IEEE Press, 138–147.

  • MIYAKAWA, M. (1988) A study on the temperature dependency of the permittivity of biological tissues. Proc. 5th Intern. Symp. Hyperthermic Oncology, 728–729.

    Google Scholar 

  • MtYAKAWA, M. (1990) An attempt of tomographic imaging of temperature change inside a body A specially designed microwave CT. Proc. 3rd Asia-Pacific Microwave Conf., 841–844.

    Google Scholar 

  • SHEPP, L. A. and LOGAN, B. F. (1974) The Fourier reconstruction of a head section. IEEE Trans., NS-21, 21–43.

    Google Scholar 

  • YAMAURA, I. (1985) Non-invasive thermometry by means of microwave active imaging. Tech. Rep. IEICE, MW85-81, 81–100.

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Check for updates. Verify currency and authenticity via CrossMark

Cite this article

Miyakawa, M. Tomographic measurement of temperature change in phantoms of the human body by chirp radar-type microwave computed tomography. Med. Biol. Eng. Comput. 31 (Suppl 1), S31–S36 (1993). https://doi.org/10.1007/BF02446647

Download citation

  • Received:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF02446647

Keywords

Navigation