Abstract
Forty-one intravenous digital subtraction angiographic (IVDSA) studies were performed in 39 patients aged 4 weeks to 19 years (mean: 9.4 years) in order to evaluate the heart, great vessels and palliative shunts. Contrast agents were injected via antecubital vein cannulation in 14 examinations. In the remaining 27, injections were made through centrally-placed catheters inserted via right antecubital or femoral veins. All but one of the centrally-injected procedures resulted in technically satisfactory images. Four of the peripherally-injected IVDSA studies were unsafisfactory or of limited value due to motion artefacts, insufficient contrast, equipment failure or perivenous extravasations. Systemic-pulmonary shunt lesions were difficult to image, but IVDSA of the aorta and pulmonary arteries provided consistently useful information.
Similar content being viewed by others
References
Chilcote WA, Modic MT, Pavlicek WA, Little JR, Furlan AJ, Duchesneau PM, Weinstein MA (1981) Digital subtraction angiography of the carotid arteries: A comparative study in 100 patients. Radiology 139:287
DeFilipp GJ, Pinto RS, Lin JP, Kricheff II (1983) Intravenous digital subtraction angiography in the investigation of intracranial disease. Radiology 148:129
Hillman BJ, Ovitt TW, Capp MP, Fisher HD III, Frost MM, Nudelman S (1982) Renal digital subtraction angiography: 100 cases. Radiology 145:643
Meaney TF, Weinstein MA, Buonocore E, Pavlicek W, Borkowski GP, Gallagher JH, Sufka B, MacIntyre WJ (1980) Digital subtraction angiography of the human cardiovascular system. AJR 135:1153
Ludwig JW, Verhoeven LAJ, Kerbsbergen JJ, Overtoom TTC (1983) Digital subtraction angiography of the pulmonary arteries for the diagnosis of pulmonary embolism. Radiology 147:639
Moodie DS, Buonocore E, Yiannikas J, Gill CC, Pavlicek WA (1982) Digital subtraction angiography in congenital heart disease in pediatric patients. Cleve Clin Q 49:159
Moodie DS, Yiannikas J, Gill CC, Buonocore E, Pavlicek W (1982) Intravenous digital subtraction angiography in the evaluation of congenital abnormalities of the aorta and aortic arch. Am Heart J 104:628
Sahn DJ, Valdes-Cruz LM, Ovitt TW, Pond G, Mammana R, Goldberg SJ, Allen HD, Copeland JG (1982) Two dimensional echocardiography and intravenous digital video subtraction angiography for diagnosis and evaluation of double aortic arch. Am J Cardiol 50:342
Wagner ML, Singleton EB, Egan ME (1983) Digital subtraction angiography in children. AJR 140:127
Buonocore E, Pavlicek W, Modic MT, Meaney TF, O'Donovan PB, Grossman LB, Moodie DS, Yiannikas J (1983) Anatomic and functional imaging of congenital heart disease with digital subtraction angiography. Radiology 147:647
Meaney TF, Weinstein MA, Buonocore E, Pavlicek W, Borkowski GP, Gallagher JH, Sufka B, MacIntyre WJ (1980) Digital subtraction angiography of the human cardiovascular system. SPIE T 233:272
Fletcher BD (1982) Digital angiography in the diagnosis of pediatric cardiovascular disorders. In: Price RR, Rollo FD, Monahan WG, James AE Jr (eds) Digital radiography: a focus on clinical utility. Grune & Stratton, p 257
Pavlicek W, Weinstein MA, Modic MT, Buonocore E, Duchesneau PM (1982) Patient doses during digital subtraction angiography of the carotid arteries: comparison with conventional angiography. Radiology 145:683
Bogren HG, Bursch JH, Brennecke R, Heintzen PH (1983) Intravenous angiocardiography using digital image processing. II. Detection of left-to-right shunts in an animal model. Invest Radiol 18:11
Bogren HG, Bursch JH, Brennecke R, Heintzen PH (1982) Intravenous angiocardiography using digital image processing. I. Experience with axial projections in normal pigs. Invest Radiol 17:216
Modic MT, Weinstein MA, Pavlicek W, Gallagher J, Duchesneau PM, Buonocore E, Meaney TF (1983) Intravenous digital subtraction angiography: Peripheral versus central injection of contrast material. Radiology 147:711
Carey PH, Slutsky RA, Ashburn WL, Higgins CB (1982) Validation of cardiac output estimates by digital video subtraction angiography in dogs. Correlation with thermodilution values. Radiology 143:623
Higgins CB, Norris SL, Gerber KH, Slutsky RA, Ashburn WL, Baily N (1982) Quantitation of left ventricular dimensions and function by digital video subtraction angiography. Radiology 144:461
Levin AR, Goldberg HL, Borer JS, Rothenberg LN, Nolan FA, Engle MA, Cohen B, Skelly NT, Carter J (1983) Digital angiography in the pediatric patient with congenital heart disease: Comparison with standard methods. Circulation 68:374
Bargeron LM Jr, Elliott LP, Soto B, Bream PR, Curry GC (1977) Axial cineangiography in congenital heart disease. Section I. Concept, technical and anatomic considerations. Circulation 56:1075
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Fletcher, B.D., Jacobstein, M.D. & Morrison, S.C. Intravenous digital subtraction angiography (IVDSA) in children. Pediatr Radiol 14, 425–430 (1984). https://doi.org/10.1007/BF02343434
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF02343434