Abstract
The wall-less proportional counter filled with propane with a small admixture of xenon was used as a spectrometer of electrons emitted by xenon atoms when photoelectrically excited by americium-241γ-rays and erbiumKα rays. TheK-shell fluorescence yield of xenon as extracted from spectra ammounts toω k=0.889(1±0.01).
Similar content being viewed by others
References
Auger, P.: Ann. Phys. (Paris)6, 183 (1926)
Martin, L.H., Eggleston, F.H.: Proc. Roy. Soc. (London), A158, 46 (1937)
West, D., Rothwell, P.: Phil. Mag.41, 873 (1950)
Heintze, J.: Z. Physik143, 153 (1955)
Troughton, M.E.: Standardization of Radionuclides, IAEA, 1967
Bambynek, W., Crasemann, B., Fink, R.W., Freund, H.U., Mark, Hans, Swift, C.D., Price, R.E., Venugopala Rao, P.: Rev. Mod. Phys.44, 716 (1972)
Blochin, M.A.: Fizika rentgenovskih lučej, Moskva 1957
Hribar, M., Kodre, A., Pahor, J.: Z. Physik A275, 323 (1975)
Hribar, M., Kodre, A., Pahor, J.: Z. Physik A272, 413 (1975)
Kostroun, V.O., Chen, M.H., Crasemann, B.: Phys. Rev. A3, 533 (1971)
Author information
Authors and Affiliations
Additional information
The work is a part of research program supported by B. Kidrič Fund
Rights and permissions
About this article
Cite this article
Hribar, M., Kodre, A. & Pahor, J. The determination of theK-shell fluorescence yield of xenon by use of the proportional counter method. Z Physik A 280, 227–229 (1977). https://doi.org/10.1007/BF01434344
Received:
Issue Date: