Advertisement

Zeitschrift für Physik A Hadrons and nuclei

, Volume 205, Issue 4, pp 303–312 | Cite as

Temperaturmessungen am Argon-Hochleistungsbogen

  • U. Bauder
Article

Abstract

Spectroscopic measurements of radial temperature distributions in the cylindric cascade arc of 5 mm diameter in argon at atmospheric pressure and 5 atm in the current range from 200 to 500 amperes are reported. The applied method is the determination of the absolute intensity of both appropriate atom and ion lines and of the continuum, where the influence of self-absorption was carefully examined by variation of the arc lenth in end-on observation. The measured axial temperatures were between 17,800 ‡K and 20,800 ‡K at atmospheric pressure and between 13,700 ‡K and 14,100 ‡K at 5 atm pressure.

Preview

Unable to display preview. Download preview PDF.

Unable to display preview. Download preview PDF.

Copyright information

© Springer-Verlag 1967

Authors and Affiliations

  • U. Bauder
    • 1
  1. 1.Elektrophysikalisches Institut der Technischen Hochschule MünchenDeutschland

Personalised recommendations