Abstract
A retrospective comparison between CT and scintigraphy with99mTechnetium-phosphate (Tc-P) and67-Gallium-citrate (Ga) has been performed in 8 children with malignant extracranial tumours and in 9 children during concurrent control after treatment. CT was superior to scintigraphy in the primary tumour evaluation with regard size, type and invasiveness of the tumour. In the same way, regression, progression or local recurrence after treatment was better visualized by CT than by Ga and Tc-P scanning. In the detection of secondary spread of the tumour, CT is the most sensitive of the modalities in the examination of the lungs, whereas Tc-P scintigraphy still is the method of choice to study metastases in the skeleton.
Similar content being viewed by others
References
Alfidi, R. J., Mac Intyre, W. J., Haaga, J. R.: The Effects of biological motion on CT resolution. Am. J. Roentgenol.127, 11 (1976)
Anderson, R. E., Osborn, A. G.: Efficacy of simple sedation for pediatric computed tomography. Radiology124, 739 (1977)
Boldt, D. W., Reilly, B. J.: Computed tomography of abdominal mass lesions in children. Radiology124, 371 (1977)
Damgaard-Pedersen, K., Jensen, J., Hertz, H.: CT whole-body scanning in pediatric radiology. Pediatr. Radiol.6, 222 (1978)
Eckelman, W. R., Reba, C., Kubota, H., Stevenson, J. S.:99mTc-pyrophosphate for bone imaging. J. Nucl. Med.5, 279 (1974)
Edeling, C.-J.: Bone scintigraphy in children. Nucl. Med.15, 228 (1976)
Edeling, C.-J.: Tumour imaging in children. Cancer38, 921 (1976)
Edwards, C. L., Hayes, R. L.: Tumour scanning with67Ga-citrate. J. Nucl. Med.10, 103 (1969)
Kreel, L.: The EMI wholebody scanner: An interim clinical evaluation of the prototype. Br. J. Clin. Equipment (1976)
Krishnamurthy, G. T., Blahd, W. H.: Technetium99mpolyphosphate bone imaging for early detection of skeletal metastasis. Nucl. Med.13, 330 (1974)
McCullough, E. C., Payne, J. T.: X-ray transmission computed tomography. Med. Phys.4, 85 (1977)
Muhm, J. R., Brown, L. R., Crowe, J. K.: Detection of pulmonary nodules by computed tomography. Am.J. Roentgenol.128, 267 (1977)
Reilly, B. J.: Extracranial computerized tomography in children. Comp. Axial Tomogr.1, 257 (1977)
Sheedy, P. F., Stephens, D. H., Hattery, R. R., Muhm, J. R., Hartman, G. W.: Computed tomography of the body: Initial clinical trial with the EMI prototype. Am. J. Roentgenol.127, 23 (1976)
Author information
Authors and Affiliations
Rights and permissions
About this article
Cite this article
Damgaard-Pedersen, K., Edeling, C.J. & Hertz, H. CT whole-body scanning and scintigraphy in children with malignant tumours. Pediatr Radiol 8, 103–107 (1979). https://doi.org/10.1007/BF00974000
Accepted:
Issue Date:
DOI: https://doi.org/10.1007/BF00974000