Skip to main content
Log in

Normal radiographic heart volume in the neonate

1. Dependence of ductal closure

  • Originals
  • Published:
Pediatric Radiology Aims and scope Submit manuscript

Abstract

The hypothesis that the normal distribution of relative heart volume in the neonatal period is a mixture of two different populations, with different means and variances, has been tested. The definition of the two populations was (i) normally patent ductus and (ii) closed ductus arteriosus. The assumed frequencies of the patency in different age-groups were taken from Gentile et coll. [5]. A material consisting of 100 neonates found to be normal has been analysed radiologically during the first 360 hours after birth. The results strongly supports the hypothesis and explains the large normal range of relative heart volume during the first 48 hours of life.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Similar content being viewed by others

References

  1. Bergström K (1969) Röntgenologisk hjärtvolymbestämning. Thesis, Department of diagnostic radiology, Uppsala, Sweden

    Google Scholar 

  2. Caffey J (1973) Pediatric X-ray diagnosis, p 429. Year Book Medical Publishers, Chicago

    Google Scholar 

  3. Du Bois D, Du Bois EF (1916) Clinical calorimetry. Arch Intern Med 17: 863

    Google Scholar 

  4. Edwards DK, Higgins Cb, Gilpin EA (1981) The cardio boracic ratio in newborn infants. AJR 136: 907

    Google Scholar 

  5. Gentile R, Stevenson G, Dooley T, Franklin D, Kawabori I, Pearlman A (1981) Pulsed Doppler echocardiographic determination of time of ductal closure in normal newborn infants. J Pediatr 98: 443

    Google Scholar 

  6. Jonsell S (1939) Method for determination of heart size by teleroentgenography. Acta Radiol 20: 325

    Google Scholar 

  7. Keats TE, Enge IP (1965) Cardiac mensuration by cardiac volume method. Radiology 85: 375

    Google Scholar 

  8. Kjellberg SR, Rudhe U, Zetterström R (1954) Heart volume variations in the neonatal period. Acta Radiol 42: 173

    Google Scholar 

  9. Larsson H, Kjellberg SR (1948) Roentgenological heart volume determination with special regard to pulse rate and the position of the body. Acta Radiol 29: 159

    Google Scholar 

  10. Lind J (1950) Heart volume in normal infants. A roentgenological study. Acta Radiol [Suppl] 82

  11. Ringertz H, Rudhe U, Wallgren G, Ghaffarpour R (1966) Rontgenologisk hjärtvolymsbestämning hos barn. Läkartidningen 63: 3764

    Google Scholar 

  12. Ringertz H (1982) Billig mätdator för rutinbruk på avdelning för diagnostisk radiologi. Läkartidningen 79: 2707

    Google Scholar 

  13. Thribeault DW, Emmanouilides GC, Dodge ME, Lachman RS (1977) Early functional closure of the ductus arteriosus associated with decreased severity of respiratory distress syndrome in preterm infants. Am J Dis Child 131: 741

    Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Ringertz, H.G. Normal radiographic heart volume in the neonate. Pediatr Radiol 13, 195–198 (1983). https://doi.org/10.1007/BF00973155

Download citation

  • Accepted:

  • Issue Date:

  • DOI: https://doi.org/10.1007/BF00973155

Key words

Navigation